{"title":"AtaGenix ELISA Kits","description":"\u003cp\u003eELISA kits from AtaGenix Laboratories for quantitative detection of proteins and biomarkers in research samples.\u003c\/p\u003e","products":[{"product_id":"bsa-elisa-kit-bhe21400006","title":"BSA ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe BSA ELISA Kit is a sandwich ELISA kit for quantitative measurement of BSA in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, BSA is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the BSA concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.54 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1 - 32 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBSA Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047343808877,"sku":"BY411018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_76fd5317-d232-4e8e-871d-a2a0750c17d1.jpg?v=1784823598"},{"product_id":"human-amyloid-1-42-elisa-kit-bhe21400004","title":"Human β-Amyloid (1-42) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Human β-Amyloid (1-42) ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human β Amyloid (1-42) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human β Amyloid (1-42) is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human β Amyloid (1-42) concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eAPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP05067\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e3.14 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e7.81 - 500 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman β Amyloid (1-42) Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047343841645,"sku":"HY235018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_ef8ff959-8309-47f2-ac05-11ee8be599c2.jpg?v=1784823598"},{"product_id":"sars-cov-2-surrogate-virus-neutralization-test-kit-jn-1-bhe21400013","title":"SARS-CoV-2 Surrogate Virus Neutralization Test Kit (JN.1)","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe SARS-CoV-2 Surrogate Virus Neutralization Test Kit (JN.1) is a competitive ELISA kit for quantitative measurement of neutralizing antibodies against SARS-CoV-2 (JN.1) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, neutralizing antibodies in the sample block the interaction between the SARS-CoV-2 RBD and ACE2 on the plate, so the optical density falls as neutralizing activity rises. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e12.56 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047343874413,"sku":"AK565098-96T","price":1698.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_27bebba9-7980-4e5f-b4b0-922205bc89f0.jpg?v=1784823597"},{"product_id":"pedv-np-nucleoprotein-elisa-kit-bhe21400010","title":"PEDV NP\/Nucleoprotein ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe PEDV NP\/Nucleoprotein ELISA Kit is a sandwich ELISA kit for quantitative measurement of PEDV NP\/Nucleoprotein in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, PEDV NP\/Nucleoprotein is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the PEDV NP\/Nucleoprotein concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.66 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEDV NP\/Nucleoprotein Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047343907181,"sku":"VK727018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_c5d563e9-23ac-4ff7-8b5d-412cce6a9143.jpg?v=1784823605"},{"product_id":"satralizumab-elisa-kit-bhe21400028","title":"Satralizumab ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Satralizumab ELISA Kit is a competitive ELISA kit for quantitative measurement of satralizumab in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, satralizumab in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the satralizumab concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eSapelizumab; SA-237; SA237; satralizumab-mwg; 1535963-91-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e8.89 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSatralizumab Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047343972717,"sku":"DY583028-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_346618e1-4c7a-4381-b046-694f776e1892.jpg?v=1784823597"},{"product_id":"human-epo-erythropoietin-elisa-kit-bhe21400009","title":"Human EPO\/Erythropoietin ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Human EPO\/Erythropoietin ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human EPO\/Erythropoietin in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human EPO\/Erythropoietin is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human EPO\/Erythropoietin concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eEPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP01588\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e10.54 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman EPO\/Erythropoietin Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047343939949,"sku":"HF703018-96T","price":716.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_ead50cd0-40ad-4073-b8df-d0d46a62ce01.jpg?v=1784823597"},{"product_id":"cgmp-elisa-kit-bhe21400007","title":"cGMP ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe cGMP ELISA Kit is a competitive ELISA kit for quantitative measurement of cGMP in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, cGMP in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the cGMP concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eCAS No.\u003c\/th\u003e\n\u003ctd\u003e7665-99-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e8.32 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecGMP Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344005485,"sku":"YA864018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_0578a9f3-bfa9-48cb-bb15-90b890b35475.jpg?v=1784823597"},{"product_id":"orforglipron-elisa-kit-bhe21400024","title":"Orforglipron ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Orforglipron ELISA Kit is a competitive ELISA kit for quantitative measurement of orforglipron in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, orforglipron in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the orforglipron concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eLY3502970; OWL 833; OWL833; OWL-833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e13.78 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrforglipron Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344038253,"sku":"DW328048-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_02a11ad3-6e9c-4223-af51-35e8b047aee5.jpg?v=1784823596"},{"product_id":"tau-pt217-elisa-kit-bhe21400001","title":"TAU pT217 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe TAU pT217 ELISA Kit is a sandwich ELISA kit for quantitative measurement of TAU pT217 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, TAU pT217 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the TAU pT217 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eMAPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP10636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e3.62 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e15.6 - 1,000 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTAU pT217 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344071021,"sku":"HY086028-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_a26f3379-a71b-425b-803e-9ce8e051de0c.jpg?v=1784823597"},{"product_id":"teriparatide-elisa-kit-bhe21400020","title":"Teriparatide ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Teriparatide ELISA Kit is a competitive ELISA kit for quantitative measurement of teriparatide in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, teriparatide in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the teriparatide concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e12.44 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeriparatide Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344103789,"sku":"DF921018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_40aa4675-5f7e-4b99-8d0e-fa38aca8b2b4.jpg?v=1784823597"},{"product_id":"pegfilgrastim-elisa-kit-bhe21400021","title":"Filgrastim ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Filgrastim ELISA Kit is a competitive ELISA kit for quantitative measurement of pegfilgrastim in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, pegfilgrastim in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the pegfilgrastim concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e14.33 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePegfilgrastim Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344136557,"sku":"DY258018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_118b2c87-cb90-4ef7-984c-5c2769fc6632.jpg?v=1784823598"},{"product_id":"dulaglutide-elisa-kit-bhe21400025","title":"Dulaglutide ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Dulaglutide ELISA Kit is a sandwich ELISA kit for quantitative measurement of dulaglutide in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, dulaglutide is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the dulaglutide concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eGLP-1Fc; LY2189265; TRULICITY®; 923950-08-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.89 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.88 - 120 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;10%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDulaglutide Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 500-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard and Detection A at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344169325,"sku":"DW328038-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/DW328038-standard-1_759c23dc-a557-4483-80e1-705fff3eaf0f.webp?v=1787688158"},{"product_id":"liraglutide-elisa-kit-bhe21400026","title":"Liraglutide ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Liraglutide ELISA Kit is a competitive ELISA kit for quantitative measurement of liraglutide in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, liraglutide in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the liraglutide concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e14.45 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiraglutide Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344234861,"sku":"DW328018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_c8083727-69b0-4c53-a264-ee38b43a96ce.jpg?v=1784823597"},{"product_id":"insulin-lispro-elisa-kit-bhe21400017","title":"Insulin Lispro ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Insulin Lispro ELISA Kit is a sandwich ELISA kit for quantitative measurement of insulin lispro in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, insulin lispro is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the insulin lispro concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e15.81 pmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e62.96 - 5,100 pmol\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;10%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 2 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 10 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 3 h 40 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the standard, Detection A, Detection B and microplate at -20 °C and the other reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344202093,"sku":"DF990038-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/DF990038-standard-1_8663f2b3-b872-45f5-9223-33f03ee0e5ed.webp?v=1787688158"},{"product_id":"hsv-2-hhv-2-us8-ge-elisa-kit-bhe21400042","title":"HSV-2\/HHV-2 US8\/gE ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HSV-2\/HHV-2 US8\/gE ELISA Kit is a sandwich ELISA kit for quantitative measurement of HSV-2\/HHV-2 US8\/gE in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HSV-2\/HHV-2 US8\/gE is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HSV-2\/HHV-2 US8\/gE concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.55 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSV-2\/HHV-2 US8\/gE Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344300397,"sku":"VK697018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_e271e298-41e0-402a-933b-2cb344bb109d.jpg?v=1784823596"},{"product_id":"tau-pt181-elisa-kit-bhe21400002","title":"TAU pT181 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe TAU pT181 ELISA Kit is a sandwich ELISA kit for quantitative measurement of TAU pT181 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, TAU pT181 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the TAU pT181 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eMAPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP10636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e5.73 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e15.6 - 1,000 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTAU pT181 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344267629,"sku":"HY086018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_4b063741-407e-4fde-957a-e5a02bb85983.jpg?v=1784823599"},{"product_id":"hsv-2-hhv-2-gd-us6-elisa-kit-bhe21400043","title":"HSV-2\/HHV-2 gD\/US6 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HSV-2\/HHV-2 gD\/US6 ELISA Kit is a sandwich ELISA kit for quantitative measurement of HSV-2\/HHV-2 gD\/US6 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HSV-2\/HHV-2 gD\/US6 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HSV-2\/HHV-2 gD\/US6 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.14 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.313 - 20 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;10%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 2 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 3 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSamples samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the standard, Detection A, Detection B and microplate at -20 °C and the other reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344333165,"sku":"VK737018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_f448f68f-5284-4575-82ce-402ba9f48514.jpg?v=1784823597"},{"product_id":"treponema-pallidum-tpp17-elisa-kit-bhe21400034","title":"Treponema pallidum TPP17 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Treponema pallidum TPP17 ELISA Kit is a sandwich ELISA kit for quantitative measurement of Treponema pallidum TPP17 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Treponema pallidum TPP17 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Treponema pallidum TPP17 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.57 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreponema pallidum TPP17 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344365933,"sku":"JN980018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_599a2e8a-ea6f-455e-a360-53d336592df1.jpg?v=1784823597"},{"product_id":"hmpv-n-nucleoprotein-elisa-kit-bhe21400029","title":"HMPV N\/Nucleoprotein ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HMPV N\/Nucleoprotein ELISA Kit is a sandwich ELISA kit for quantitative measurement of HMPV N\/Nucleoprotein in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HMPV N\/Nucleoprotein is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HMPV N\/Nucleoprotein concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.03 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.63 - 40 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;10%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMPV N\/Nucleoprotein Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344398701,"sku":"VK571018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/VK571018-standard-1_45a6c868-0430-46cb-a3ce-d8a5b1eeb621.webp?v=1787688158"},{"product_id":"human-amyloid-1-40-elisa-kit-bhe21400003","title":"Human β-Amyloid (1-40) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Human β-Amyloid (1-40) ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human β Amyloid (1-40) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human β Amyloid (1-40) is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human β Amyloid (1-40) concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eAPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP05067\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.22 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman β Amyloid (1-40) Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344464237,"sku":"HY235028-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_20d6a038-d1e1-498b-8fd1-eff63fe3313d.jpg?v=1784823599"},{"product_id":"anti-marv-envelope-glycoprotein-gp-human-igg-elisa-kit-bhe21400054","title":"Anti-MARV Envelope glycoprotein (GP) Human IgG ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-MARV Envelope glycoprotein (GP) Human IgG ELISA Kit is an indirect ELISA kit for quantitative measurement of human IgG antibodies against MARV Envelope glycoprotein (GP) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, human IgG antibodies against MARV Envelope glycoprotein (GP) in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.73 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344431469,"sku":"AK669018-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_9e8f7461-0157-4171-8038-a2f923f4e888.jpg?v=1784823598"},{"product_id":"hmpv-f-fusion-glycoprotein-f0-elisa-kit-bhe21400031","title":"HMPV F\/Fusion glycoprotein F0 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HMPV F\/Fusion glycoprotein F0 ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human metapneumovirus fusion glycoprotein F in serum and plasma. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human metapneumovirus fusion glycoprotein F is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human metapneumovirus fusion glycoprotein F concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.87 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman metapneumovirus fusion glycoprotein F Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344497005,"sku":"VK430018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_55cade0c-c5ae-4b97-99fc-b4e59b92557f.jpg?v=1784823597"},{"product_id":"insulin-aspart-elisa-kit-bhe21400018","title":"Insulin Aspart ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Insulin Aspart ELISA Kit is a sandwich ELISA kit for quantitative measurement of insulin aspart in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, insulin aspart is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the insulin aspart concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e13.32 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulin aspart Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344529773,"sku":"DF990028-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_611ed1be-3d5e-4f31-b01b-651920aed33b.jpg?v=1784823598"},{"product_id":"retatrutide-elisa-kit-bhe21400023","title":"Retatrutide ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Retatrutide ELISA Kit is a competitive ELISA kit for quantitative measurement of retatrutide in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, retatrutide in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the retatrutide concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eLY3437943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e26.24 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e156.25 - 10,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the standard, Detection A, Detection B and microplate at -20 °C and the other reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344562541,"sku":"DW328058-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/DW328058-standard-1_ceeb6bb9-3765-4071-ba35-12fed554ab3c.webp?v=1787688158"},{"product_id":"sars-cov-2-surrogate-virus-neutralization-test-kit-kp-2-bhe21400012","title":"SARS-CoV-2 Surrogate Virus Neutralization Test Kit (KP.2)","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe SARS-CoV-2 Surrogate Virus Neutralization Test Kit (KP.2) is a competitive ELISA kit for quantitative measurement of neutralizing antibodies against SARS-CoV-2 (KP.2) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, neutralizing antibodies in the sample block the interaction between the SARS-CoV-2 RBD and ACE2 on the plate, so the optical density falls as neutralizing activity rises. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e9.57 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e15.63 - 1,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 15 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the standard, Detection A and microplate at -20 °C and the other reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344595309,"sku":"AK565108-96T","price":1698.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/AK565108-standard-1_49c7c6e1-3f35-4e36-877e-37dd0e4f3d34.webp?v=1787688158"},{"product_id":"anti-sars-cov-2-nucleocapsid-np-mouse-igg-elisa-kit-bhe21400071","title":"Anti-SARS-CoV-2 Nucleocapsid (NP) Mouse IgG ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-SARS-CoV-2 Nucleocapsid (NP) Mouse IgG ELISA Kit is an indirect ELISA kit for quantitative measurement of mouse IgG antibodies against SARS-CoV-2 Nucleocapsid (NP) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, mouse IgG antibodies against SARS-CoV-2 Nucleocapsid (NP) in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.26 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344660845,"sku":"AK805018-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_f962ea73-4b22-4531-ae43-d615399daf32.jpg?v=1784823607"},{"product_id":"weev-spike-glycoprotein-e2-elisa-kit-bhe21400041","title":"WEEV Spike glycoprotein E2 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe WEEV Spike glycoprotein E2 ELISA Kit is a sandwich ELISA kit for quantitative measurement of WEEV Spike glycoprotein E2 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, WEEV Spike glycoprotein E2 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the WEEV Spike glycoprotein E2 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.75 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEV Spike glycoprotein E2 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344628077,"sku":"VK634018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_61d9e5e4-034d-4adc-930a-2fe621d21d98.jpg?v=1784823597"},{"product_id":"protein-a-elisa-kit-bhe21400005","title":"Protein A ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Protein A ELISA Kit is a sandwich ELISA kit for quantitative measurement of Protein A in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Protein A is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Protein A concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e7.43 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e15.625 - 1,000 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtein A Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344726381,"sku":"JN856018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_ce12f063-af55-45d1-9c65-4309ab70575f.jpg?v=1784823596"},{"product_id":"hmpv-m-matrix-protein-elisa-kit-bhe21400030","title":"HMPV M\/Matrix protein ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HMPV M\/Matrix protein ELISA Kit is a sandwich ELISA kit for quantitative measurement of HMPV M\/Matrix protein in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HMPV M\/Matrix protein is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HMPV M\/Matrix protein concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.75 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMPV M\/Matrix protein Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344693613,"sku":"VK777018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_623dea7b-a600-42e5-af52-d3ad3e8c6eab.jpg?v=1784823598"},{"product_id":"camp-elisa-kit-bhe21400008","title":"cAMP ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe cAMP ELISA Kit is a competitive ELISA kit for quantitative measurement of cAMP in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, cAMP in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the cAMP concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e9.52 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecAMP Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344759149,"sku":"YP051018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_46f1ef4f-f54e-47a0-a5e5-597a3c5416e5.jpg?v=1784823598"},{"product_id":"sars-cov-2-rbd-kp-2-elisa-kit-bhe21400068","title":"SARS-CoV-2 RBD (KP.2) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe SARS-CoV-2 RBD (KP.2) ELISA Kit is a sandwich ELISA kit for quantitative measurement of SARS-CoV-2 RBD (KP.2) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, SARS-CoV-2 RBD (KP.2) is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the SARS-CoV-2 RBD (KP.2) concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e5.92 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e12.5 - 800 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSARS-CoV-2 RBD (KP.2) Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344791917,"sku":"VK565058-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_714a1676-28a6-4f86-9943-694ed6c0852a.jpg?v=1784823598"},{"product_id":"hsv-2-hhv-2-gc-ul44-elisa-kit-bhe21400045","title":"HSV-2\/HHV-2 gC\/UL44 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HSV-2\/HHV-2 gC\/UL44 ELISA Kit is a sandwich ELISA kit for quantitative measurement of HSV-2\/HHV-2 gC\/UL44 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HSV-2\/HHV-2 gC\/UL44 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HSV-2\/HHV-2 gC\/UL44 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.38 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSV-2\/HHV-2 gC\/UL44 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344824685,"sku":"VK701018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_d4c3f99d-eb39-42ec-baf6-d86375c7771f.jpg?v=1784823597"},{"product_id":"hsv-1-hhv-1-gd-elisa-kit-bhe21400047","title":"HSV-1\/HHV-1 gD ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HSV-1\/HHV-1 gD ELISA Kit is a sandwich ELISA kit for quantitative measurement of HSV-1\/HHV-1 gD in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HSV-1\/HHV-1 gD is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HSV-1\/HHV-1 gD concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.34 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.78 - 50 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSV-1\/HHV-1 gD Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344857453,"sku":"VK413018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_08b115bf-310b-4941-b0f9-890ba5b67363.jpg?v=1784823596"},{"product_id":"marv-nucleoprotein-np-elisa-kit-bhe21400051","title":"MARV Nucleoprotein (NP) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe MARV Nucleoprotein (NP) ELISA Kit is a sandwich ELISA kit for quantitative measurement of MARV Nucleoprotein (NP) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, MARV Nucleoprotein (NP) is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the MARV Nucleoprotein (NP) concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.04 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.07 - 50 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMARV Nucleoprotein (NP) Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344890221,"sku":"VK660018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_bfd02fd3-c9be-4998-989d-430a9aa3af03.jpg?v=1784823608"},{"product_id":"pedv-spike-glycoprotein-rbd-elisa-kit-bhe21400011","title":"PEDV Spike glycoprotein (RBD) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe PEDV Spike glycoprotein (RBD) ELISA Kit is a sandwich ELISA kit for quantitative measurement of PEDV Spike glycoprotein (RBD) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, PEDV Spike glycoprotein (RBD) is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the PEDV Spike glycoprotein (RBD) concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.64 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEDV Spike glycoprotein (RBD) Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344922989,"sku":"VK564018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_ed5ba9a4-6e04-4e9b-af6d-ad7e3b890465.jpg?v=1784823598"},{"product_id":"aldafermin-elisa-kit-bhe21400015","title":"Aldafermin ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Aldafermin ELISA Kit is a competitive ELISA kit for quantitative measurement of aldafermin in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, aldafermin in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the aldafermin concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eNGM282; 1616639-03-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e16.41 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAldafermin Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344955757,"sku":"DF862018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_dda0fcce-37a3-4ecb-aa77-7741626bc643.jpg?v=1784823604"},{"product_id":"anti-tirzepatide-ly3298176-human-igg-elisa-kit-bhe21400014","title":"Anti-Tirzepatide (LY3298176) Human IgG ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-Tirzepatide (LY3298176) Human IgG ELISA Kit is an indirect ELISA kit for quantitative measurement of human IgG antibodies against tirzepatide (LY3298176) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, human IgG antibodies against tirzepatide (LY3298176) in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eTirzepatide; LY3298176; 2023788-19-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.85 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047344988525,"sku":"AP899028-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_77b17465-8e48-44ad-a642-054bd79f2709.jpg?v=1784823597"},{"product_id":"albiglutide-elisa-kit-bhe21400022","title":"Albiglutide ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Albiglutide ELISA Kit is a competitive ELISA kit for quantitative measurement of albiglutide in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this competitive format, albiglutide in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the albiglutide concentration rises. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eCompetitive (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e13.99 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e31.25 - 2,000 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlbiglutide Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345021293,"sku":"DW328068-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_b9e02fd7-f7fe-4a38-b4e8-c9fdbb6f9887.jpg?v=1784823598"},{"product_id":"anti-mpxv-a29l-human-iga-elisa-kit-bhe21400084","title":"Anti-MPXV A29L Human IgA ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-MPXV A29L Human IgA ELISA Kit is an indirect ELISA kit for quantitative measurement of human IgA antibodies against MPXV A29L in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, human IgA antibodies against MPXV A29L in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.83 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345054061,"sku":"AK415048-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_56e42397-83a1-4feb-9357-25574fb5c45a.jpg?v=1784823607"},{"product_id":"human-atp7b-elisa-kit-bhe21400036","title":"Human ATP7B ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Human ATP7B ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human ATP7B in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human ATP7B is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human ATP7B concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eATP7B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP35670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.06 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.156 - 10 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman ATP7B Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345086829,"sku":"HW635018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_9612f04b-199c-4862-bd6a-180d8b48572d.jpg?v=1784823604"},{"product_id":"human-erbb2-elisa-kit-bhe21400067","title":"Human ERBB2 (HER2) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Human ERBB2 (HER2) ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human ERBB2 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human ERBB2 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human ERBB2 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eERBB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP04626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e14.9 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e78.1 - 5,000 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman ERBB2 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345119597,"sku":"HY286028-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_79500551-9269-46b8-8171-e86c9ec0fd8c.jpg?v=1784823596"},{"product_id":"eeev-spike-glycoprotein-e2-elisa-kit-bhe21400039","title":"EEEV Spike glycoprotein E2 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe EEEV Spike glycoprotein E2 ELISA Kit is a sandwich ELISA kit for quantitative measurement of EEEV Spike glycoprotein E2 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, EEEV Spike glycoprotein E2 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the EEEV Spike glycoprotein E2 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.37 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEEEV Spike glycoprotein E2 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345152365,"sku":"VK634038-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_98dd07ed-3d56-40e8-8070-b8883817a1ed.jpg?v=1784823604"},{"product_id":"anti-mpxv-m1r-human-igm-elisa-kit-bhe21400089","title":"Anti-MPXV M1R Human IgM ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-MPXV M1R Human IgM ELISA Kit is an indirect ELISA kit for quantitative measurement of human IgM antibodies against MPXV M1R in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, human IgM antibodies against MPXV M1R in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.58 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345185133,"sku":"AK785038-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_a855eec9-ddfd-48b5-ac64-d334af04e4e8.jpg?v=1784823607"},{"product_id":"human-scd14-elisa-kit-bhe21400122","title":"Human sCD14 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Human sCD14 ELISA Kit is a sandwich ELISA kit for quantitative measurement of Human sCD14 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, Human sCD14 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the Human sCD14 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eTarget\u003c\/th\u003e\n\u003ctd\u003eCD14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUniProt\u003c\/th\u003e\n\u003ctd\u003eP08571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternative Names\u003c\/th\u003e\n\u003ctd\u003eMyeloid cell-specific leucine-rich glycoprotein; CD14; Monocyte differentiation antigen CD14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e42.4 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e125 - 8,000 pg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman sCD14 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345217901,"sku":"HY038018-96T","price":646.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_67890d74-3181-4fd8-a51e-d5d33ed4f9d1.jpg?v=1784823607"},{"product_id":"dsrna-elisa-kit-bhe21400037","title":"dsRNA ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe dsRNA ELISA Kit is a sandwich ELISA kit for quantitative measurement of dsRNA in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, dsRNA is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the dsRNA concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.09 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.16 - 10 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;10%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the standard, Detection A, Detection B and microplate at -20 °C and the other reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345250669,"sku":"YP150018-96T","price":848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/YP150018-standard-1_126340f6-0b65-4a3a-a902-0bee78ea8227.webp?v=1787688158"},{"product_id":"anti-sars-cov-2-spike-protein-beta-b-1-351-human-igg-elisa-kit-bhe21400081","title":"Anti-SARS-CoV-2 Spike Protein (Beta\/B.1.351) Human IgG ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-SARS-CoV-2 Spike Protein (Beta\/B.1.351) Human IgG ELISA Kit is an indirect ELISA kit for quantitative measurement of human IgG antibodies against SARS-CoV-2 Spike Protein (Beta\/B.1.351) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, human IgG antibodies against SARS-CoV-2 Spike Protein (Beta\/B.1.351) in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.67 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345283437,"sku":"AK474028-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_42ffddb4-bce3-4826-bab1-f37425e8c9d9.jpg?v=1784823603"},{"product_id":"marv-envelope-glycoprotein-gp-elisa-kit-bhe21400055","title":"MARV Envelope glycoprotein (GP) ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe MARV Envelope glycoprotein (GP) ELISA Kit is an indirect ELISA kit for quantitative measurement of MARV Envelope glycoprotein (GP) in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, MARV Envelope glycoprotein (GP) in the sample binds in the pre-coated wells and is then detected with an enzyme-labeled reagent, so the optical density rises with the MARV Envelope glycoprotein (GP) level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.04 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.07 - 50 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMARV Envelope glycoprotein (GP) Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345316205,"sku":"VK669018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_65dd61fb-2f3c-4cdf-a475-d6bccf18e9f5.jpg?v=1784823606"},{"product_id":"hmpv-g-major-surface-glycoprotein-g-elisa-kit-bhe21400032","title":"HMPV G\/Major surface glycoprotein G ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe HMPV G\/Major surface glycoprotein G ELISA Kit is a sandwich ELISA kit for quantitative measurement of HMPV G\/Major surface glycoprotein G in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, HMPV G\/Major surface glycoprotein G is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the HMPV G\/Major surface glycoprotein G concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.02 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e0.07 - 50 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMPV G\/Major surface glycoprotein G Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345348973,"sku":"VK673018-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_e0da0e85-3613-4c26-8436-61f868a80d64.jpg?v=1784823596"},{"product_id":"anti-mpxv-m1r-human-iga-elisa-kit-bhe21400088","title":"Anti-MPXV M1R Human IgA ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Anti-MPXV M1R Human IgA ELISA Kit is an indirect ELISA kit for quantitative measurement of human IgA antibodies against MPXV M1R in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this indirect format, human IgA antibodies against MPXV M1R in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003cp\u003eValues are expressed relative to the antibody standard supplied with the kit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eIndirect (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.74 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: dilute in Standard Diluent before the assay and confirm the dilution in a pilot run so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345414509,"sku":"AK785048-96T","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_ae7d7c5e-1ead-4dfe-968d-97b54196a06c.jpg?v=1784823604"},{"product_id":"weev-spike-glycoprotein-e1-elisa-kit-bhe21400040","title":"WEEV Spike glycoprotein E1 ELISA Kit","description":"\u003cdiv class=\"bhp-desc\"\u003e\n\u003cstyle\u003e.bhp-desc{font-size:16px;color:#1a1a1a;line-height:1.7}.bhp-desc h2{font-size:18px;font-weight:700;color:#003366;margin:24px 0 10px;padding-bottom:6px;border-bottom:2px solid #003366}.bhp-desc p{margin:0 0 12px}.bhp-desc .bhp-spec-table{width:100%;border-collapse:collapse;margin:12px 0 18px}.bhp-desc .bhp-spec-table th{width:36%;text-align:left;padding:8px 12px;background:#e8f0fb;color:#003366;font-weight:600;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-spec-table td{padding:8px 12px;vertical-align:top;border:1px solid #ccd9f0}.bhp-desc .bhp-warning-box{background:#fff8e6;border-left:4px solid #e6a817;padding:10px 14px;margin:10px 0 14px;border-radius:0 4px 4px 0}\u003c\/style\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe WEEV Spike glycoprotein E1 ELISA Kit is a sandwich ELISA kit for quantitative measurement of WEEV Spike glycoprotein E1 in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.\u003c\/p\u003e\n\u003cp\u003eIn this sandwich format, WEEV Spike glycoprotein E1 is captured in the pre-coated wells and then bound by a detection reagent, so the optical density rises with the WEEV Spike glycoprotein E1 concentration. Concentrations are calculated from the standard curve run on the same plate.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth\u003eAssay Type\u003c\/th\u003e\n\u003ctd\u003eSandwich (Quantitative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Method\u003c\/th\u003e\n\u003ctd\u003eColorimetric (OD 450 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Type\u003c\/th\u003e\n\u003ctd\u003eSerum, Plasma, Other Biological Fluid Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003e0.33 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003ctd\u003e1.56 - 100 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecovery\u003c\/th\u003e\n\u003ctd\u003e80-120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrecision\u003c\/th\u003e\n\u003ctd\u003eIntra-assay CV \u0026lt;15%; Inter-assay CV \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKit Size\u003c\/th\u003e\n\u003ctd\u003e96 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping\u003c\/th\u003e\n\u003ctd\u003e2-8 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Components\u003c\/h2\u003e\n\u003ctable class=\"bhp-spec-table\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:auto\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eQuantity\u003c\/th\u003e\n\u003cth style=\"width:auto\"\u003eStorage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-coated Microplate\u003c\/td\u003e\n\u003ctd\u003e1 plate\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEV Spike glycoprotein E1 Standard\u003c\/td\u003e\n\u003ctd\u003e2 bottles\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection A\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection B\u003c\/td\u003e\n\u003ctd\u003e1 vial\u003c\/td\u003e\n\u003ctd\u003e-20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Diluent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20× Wash Buffer\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Reagent\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop Solution\u003c\/td\u003e\n\u003ctd\u003e1 bottle\u003c\/td\u003e\n\u003ctd\u003e4 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlate Sealers\u003c\/td\u003e\n\u003ctd\u003e4 strips\u003c\/td\u003e\n\u003ctd\u003eRoom temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAssay Procedure (Summary)\u003c\/h2\u003e\n\u003cp\u003eBring all reagents to room temperature and prepare working solutions and the standard series before starting.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd 100 µL standard or sample; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection A working solution; incubate 1 h at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 3 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Detection B working solution; incubate 30 min at 37 °C.\u003c\/li\u003e\n\u003cli\u003eWash 5 times with 300 µL wash buffer per well.\u003c\/li\u003e\n\u003cli\u003eAdd 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.\u003c\/li\u003e\n\u003cli\u003eAdd 50 µL stop solution; the color turns from blue to yellow.\u003c\/li\u003e\n\u003cli\u003eRead the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eTotal incubation time is about 2 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.\u003c\/p\u003e\n\u003ch2\u003eSample Preparation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSerum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.\u003c\/li\u003e\n\u003cli\u003ePlasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.\u003c\/li\u003e\n\u003cli\u003eAssay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003eSerum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n\u003cdiv class=\"bhp-warning-box\"\u003eShips at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.\u003c\/div\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AtaGenix Laboratories","offers":[{"title":"96 T","offer_id":53047345381741,"sku":"VK634028-96T","price":1226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/abinScience_Kit_Placeholder_Image_a896bf5d-cf23-41b0-8d61-d5b6b9356104.jpg?v=1784823606"}],"url":"https:\/\/www.ebiohippo.com\/collections\/atagenix-elisa-kits.oembed?page=16","provider":"BioHippo","version":"1.0","type":"link"}