{"product_id":"cd52-unconjugated-bha19900508","title":"CD52 Unconjugated","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\u003cp\u003eCD52 Unconjugated is a Mouse monoclonal targeting CD52, supplied as a Unconjugated format for FC workflows. It supports measurement of African Green, Pigtailed Macaque, Baboon, Human, Rhesus target expression in common experimental systems.\u003c\/p\u003e\u003ch2\u003eKey elements and design rationale\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClone:\u003c\/strong\u003e CF-1D12 — consistent clone identity can support panel reproducibility and cross-study comparisons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsotype:\u003c\/strong\u003e IgG3, k — informs selection of matched controls and secondary reagents when relevant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConjugate:\u003c\/strong\u003e Unconjugated — enables direct detection in fluorescence-based assays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost species:\u003c\/strong\u003e Mouse — useful for panel design and control strategy planning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReactivity:\u003c\/strong\u003e African Green, Pigtailed Macaque, Baboon, Human, Rhesus — interpret staining in the context of species-specific sequence and expression differences.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eKey specifications such as clone identity, isotype, and fluorophore conjugation help researchers align panel design, control selection, and instrument configuration with the biological question and sample type.\u003c\/p\u003e\u003ch2\u003eBiological background\u003c\/h2\u003e\u003cp\u003eThe clone CF-1D12 recognizes human CD52, a 21-28 kDa glycoprotein whose C-terminus is glycophosphatidylinositol (GPI) anchored within the membrane. It is also known as Cambridge pathology antigen 1 (CAMPATH-1). Binding of CF-1D12 with CD52 induces a potent complement-mediated cytolytic immune response of matured lymphocytes. It is widely expressed on the surface of thymocytes and mature lymphocytes, on monocytes, dendritic cells, eosinophils and epithelial cells of the epididymis and seminal vesicles but not on neutrophils, plasma cells, platelets or erythrocytes.\u003c\/p\u003e\u003ch2\u003eResearch relevance and current trends\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHigh-parameter immunophenotyping: combining CD52 with complementary lineage and activation markers to resolve complex cell states.\u003c\/li\u003e\n\u003cli\u003ePanel standardization and data comparability: increasing emphasis on consistent reagents, compensation-aware fluorophore choices, and shared gating strategies.\u003c\/li\u003e\n\u003cli\u003eIntegration with single-cell multi-omics: pairing surface marker profiling with transcriptomic or proteomic readouts to connect phenotype to function.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon research applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFlow cytometry: quantify CD52-positive populations and compare expression distributions across conditions or time points.\u003c\/li\u003e\n\u003cli\u003eCell sorting: enrich CD52-defined subsets for downstream RNA\/protein assays or functional readouts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eChanges in measured signal are typically interpreted in the context of cell subset frequency, activation\/differentiation state, and sample processing effects rather than as a standalone readout.\u003c\/p\u003e\u003ch2\u003eNotes for experimental interpretation\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFluorophore selection: consider brightness, spectral overlap, and instrument configuration; compensation and spillover can affect apparent population boundaries.\u003c\/li\u003e\n\u003cli\u003eBiology-driven confounders: activation state, differentiation, and isoform\/PTM variation can shift epitope accessibility and apparent expression.\u003c\/li\u003e\n\u003cli\u003eControl concepts: include matched isotype and fluorescence-minus-one (FMO) controls where appropriate, and interpret results alongside biological positive\/negative reference samples.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor antibody-based assays, monoclonal versus polyclonal format can influence epitope recognition breadth and signal consistency. Conjugated antibodies support direct detection and can simplify multicolor panel design when paired with appropriate controls and instrument settings.\u003c\/p\u003e\u003c!-- Sources (internal): - UniProt Knowledgebase — UniProt — https:\/\/www.uniprot.org\/ - NCBI Gene — NCBI — https:\/\/www.ncbi.nlm.nih.gov\/gene\/ - HGNC gene nomenclature — HUGO Gene Nomenclature Committee — https:\/\/www.genenames.org\/ - Flow cytometry basics — NIH\/NCI (overview resources) — https:\/\/www.cancer.gov\/research\/resources - High-dimensional cytometry overview — Nature Methods (journal) — https:\/\/www.nature.com\/nmeth\/ --\u003e","brand":"Caprico","offers":[{"title":"100 ug","offer_id":53072767975789,"sku":"108501","price":110.0,"currency_code":"USD","in_stock":true},{"title":"500 ug","offer_id":53072837443949,"sku":"108503","price":390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/caprico_logo_b3327fc7-399c-4de5-b63d-a73dc4405d84.png?v=1772634881","url":"https:\/\/www.ebiohippo.com\/products\/cd52-unconjugated-bha19900508","provider":"BioHippo","version":"1.0","type":"link"}