{"product_id":"enzychrom-glycogen-assay-kit-bht15600105","title":"EnzyChrom™ Glycogen Assay Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eFor quantitative determination of glycogen and evaluation of drug effects on glycogen metabolism. The assay uses OD570nm, or FL530\/585nm for signal readout. Compatible sample input includes Biological. Typical stated assay timing is 30 min.\u003c\/p\u003e\n\n\u003ch2\u003eKey elements and design rationale\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReadout format:\u003c\/strong\u003e OD570nm, or FL530\/585nm supports plate-based signal acquisition and consistent comparison across matched samples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSample compatibility:\u003c\/strong\u003e The stated sample scope includes Biological, which is useful when aligning matrix type with calibration and control design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalytical range context:\u003c\/strong\u003e The supplied specifications include a stated detection limit of OD, FL: 2, 0.2 µg\/mL for interpreting low-signal samples.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable format information for this listing includes 100 Tests.\u003c\/p\u003e\n\n\u003ch2\u003eBiological background\u003c\/h2\u003e\n\u003cp\u003eThis product is centered on measurement of glycogen within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.\u003c\/p\u003e\n\n\u003ch2\u003eMore details\u003c\/h2\u003e\n\u003cp\u003e\u003ci\u003e GLYCOGEN \u003c\/i\u003eis a branched polysaccharide of glucose units linked by α-1,4 glycosidic bonds and α-1,6 glycosidic bonds. It is stored primarily in the liver and muscle and forms an energy reserve that can be quickly mobilized to meet a sudden need for glucose. The most common glycogen metabolism disorder is found in diabetes, in which, due to abnormal amounts of insulin, liver glycogen can be abnormally accumulated or depleted. Genetic glycogen storage diseases have been associated with various inborn errors of metabolism caused by deficiencies of enzymes necessary for glycogen synthesis or breakdown. Simple, direct, and automation-ready procedures for measuring glycogen concentrations find wide applications in research and drug discovery. BioAssay Systems glycogen assay uses a single Working Reagent that combines the enzymatic breakdown of glycogen and the detection of glucose in one step. The color intensity of the reaction product at 570nm or fluorescence intensity at λex\/em = 530\/585 nm is directly proportional to the glycogen concentration in the sample. This simple convenient assay is carried out at room temperature and takes only 30 min.\u003c\/p\u003e\n\n\u003ch2\u003eDetection method\u003c\/h2\u003e\n\u003cp\u003eColorimetric (OD 570 nm) or Fluorescent (FL 530\/585 nm).\u003c\/p\u003e\n\n\u003ch2\u003eDetection limit and analytical sensitivity\u003c\/h2\u003e\n\u003cp\u003eReported detection limit(s): Colorimetric: 2 µg\/mL \/ Fluorescent: 0.2 µg\/mL. Additional source wording: OD, FL: 2, 0.2 µg\/mL.\u003c\/p\u003e\n\n\u003ch2\u003eProcedures and timing\u003c\/h2\u003e\n\u003cp\u003eStated procedure or timing information: 30 min.\u003c\/p\u003e\n\n\u003ch2\u003eResearch relevance and current trends\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePlate-based quantification and side-by-side group comparison remain central use cases for this assay format.\u003c\/li\u003e\n  \u003cli\u003eThe description supports intervention-focused study designs in which researchers compare baseline and perturbed conditions.\u003c\/li\u003e\n  \u003cli\u003eShort assay timing and plate compatibility support time-course or repeated-measure collection plans when handling is kept consistent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCommon research applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eQuantify glycogen in biological by OD570 nm, or FL530\/585 nm readout.\u003c\/li\u003e\n  \u003cli\u003eCompare treatment or phenotype groups using matched biological handling.\u003c\/li\u003e\n  \u003cli\u003eMonitor time-course or pre\/post changes in biological across study conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInterpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.\u003c\/p\u003e\n\n\u003ch2\u003eNotes for experimental interpretation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMatrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.\u003c\/li\u003e\n  \u003cli\u003eUse appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Sources (internal):\n- Product Description column\n- Key Features column\n- More Details column\n- Method \/ Sample Type(s) \/ Assay Time \/ Detection Limit \/ Detection Method columns\n- Procedures column\n- Screening Services column\n--\u003e","brand":"BioAssay Systems","offers":[{"title":"100 Tests","offer_id":53238314205549,"sku":"E2GN-100","price":515.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/E2GNfig.jpg?v=1776668350","url":"https:\/\/www.ebiohippo.com\/products\/enzychrom-glycogen-assay-kit-bht15600105","provider":"BioHippo","version":"1.0","type":"link"}