{"product_id":"quantichrom-bcp-albumin-assay-kit-bht15600053","title":"QuantiChrom™ BCP Albumin Assay Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eFor quantitative determination of albumin and evaluation of drug effects on albumin metabolism. The assay uses OD610nm (BCP) for signal readout. Compatible sample input includes Serum, plasma, urine, biological preparations. Typical stated assay timing is 5 min.\u003c\/p\u003e\n\n\u003ch2\u003eKey elements and design rationale\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReadout format:\u003c\/strong\u003e OD610nm (BCP) supports plate-based signal acquisition and consistent comparison across matched samples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSample compatibility:\u003c\/strong\u003e The stated sample scope includes Serum, plasma, urine, biological preparations, which is useful when aligning matrix type with calibration and control design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalytical range context:\u003c\/strong\u003e The supplied specifications include a stated detection limit of 0.3 g\/dL for interpreting low-signal samples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeature emphasis:\u003c\/strong\u003e Sensitive and accurate. Use as little as 20 µL samples. Detection range 0.3 – 5 g\/dL (45 – 750 µM) albumin in a 96-well plate assay.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional feature notes highlight Simple and high-throughput. The procedure involves the addition of a single working reagent and incubation for 5 min. Can be readily automated as a high-throughput assay for thousands of samples per day; Improved reagent stability and versatility. The optimized formulation has greatly enhanced the reagent and signal stability. Cuvet or 96-well plate assay. Available format information for this listing includes 250 Tests.\u003c\/p\u003e\n\n\u003ch2\u003eBiological background\u003c\/h2\u003e\n\u003cp\u003eThis product is centered on measurement of bcp albumin within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.\u003c\/p\u003e\n\n\u003ch2\u003eMore details\u003c\/h2\u003e\n\u003cp\u003e\u003ci\u003eAlbumin\u003c\/i\u003eis the most abundant plasma protein in humans. It accounts for about 60% of the total serum protein. Albumin plays important physiological roles, including the maintenance of colloid osmotic pressure, and binding of key substances such as long-chain fatty acids, bile acids, bilirubin, haematin, calcium, and magnesium. It has anti-oxidant and anticoagulant effects, and also acts as a carrier for nutritional factors and drugs, as an effective plasma pH buffer. Serum albumin is a reliable prognostic indicator for morbidity and mortality, liver disease, nephritic syndrome, malnutrition, and protein-losing enteropathies. High levels are associated with dehydration. Simple, direct, and automation-ready procedures for measuring albumin concentration in biological samples are becoming popular in Research and Drug Discovery. BioAssay Systems BCP albumin assay kit is designed to measure albumin directly in biological samples without any pretreatment. The improved method utilizes bromcresol purple that forms a colored complex specifically with albumin. The intensity of the color, measured at 610nm, is directly proportional to the albumin concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw samples.\u003c\/p\u003e\n\n\u003ch2\u003eDetection method\u003c\/h2\u003e\n\u003cp\u003eColorimetric (OD 610 nm).\u003c\/p\u003e\n\n\u003ch2\u003eDetection limit and analytical sensitivity\u003c\/h2\u003e\n\u003cp\u003eReported detection limit: 0.3 g\/dL.\u003c\/p\u003e\n\n\u003ch2\u003eProcedures and timing\u003c\/h2\u003e\n\u003cp\u003eStated procedure or timing information: 5 min.\u003c\/p\u003e\n\n\u003ch2\u003eResearch relevance and current trends\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePlate-based quantification and side-by-side group comparison remain central use cases for this assay format.\u003c\/li\u003e\n  \u003cli\u003eThe product notes emphasize multi-sample throughput, making it relevant for screening-oriented and larger batch comparison studies.\u003c\/li\u003e\n  \u003cli\u003eThe description supports intervention-focused study designs in which researchers compare baseline and perturbed conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCommon research applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eQuantify bcp albumin in serum, plasma, urine, biological preparations by OD610 nm (BCP) readout.\u003c\/li\u003e\n  \u003cli\u003eCompare treatment or phenotype groups using matched serum, plasma, urine, biological preparations handling.\u003c\/li\u003e\n  \u003cli\u003eMonitor time-course or pre\/post changes in serum, plasma, urine, biological preparations across study conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInterpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.\u003c\/p\u003e\n\n\u003ch2\u003eNotes for experimental interpretation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMatrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.\u003c\/li\u003e\n  \u003cli\u003eUse appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Sources (internal):\n- Product Description column\n- Key Features column\n- More Details column\n- Method \/ Sample Type(s) \/ Assay Time \/ Detection Limit \/ Detection Method columns\n- Procedures column\n- Screening Services column\n--\u003e","brand":"BioAssay Systems","offers":[{"title":"250 Tests","offer_id":53238316106093,"sku":"DIAP-250","price":419.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/DIAPfig.jpg?v=1776668347","url":"https:\/\/www.ebiohippo.com\/products\/quantichrom-bcp-albumin-assay-kit-bht15600053","provider":"BioHippo","version":"1.0","type":"link"}