{"product_id":"quantichrom-cobalt-assay-kit-bht15600030","title":"QuantiChrom™ Cobalt Assay Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eDirect Assays: cobalt in aqueous samples. The assay uses OD485nm for signal readout. Compatible sample input includes Aqueous samples. Typical stated assay timing is 10 min.\u003c\/p\u003e\n\n\u003ch2\u003eKey elements and design rationale\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReadout format:\u003c\/strong\u003e OD485nm supports plate-based signal acquisition and consistent comparison across matched samples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSample compatibility:\u003c\/strong\u003e The stated sample scope includes Aqueous samples, which is useful when aligning matrix type with calibration and control design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalytical range context:\u003c\/strong\u003e The supplied specifications include a stated detection limit of 1.4µM for interpreting low-signal samples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeature emphasis:\u003c\/strong\u003e Sensitive and accurate. Linear detection range from 1.4 µM to 200 µM cobalt ions in a 96-well plate assay.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional feature notes highlight Simple and high-throughput. The procedure involves the addition of a single working reagent with immediate color development. Can be readily automated as a high-throughput assay for thousands of samples per day; Improved reagent stability and versatility. The optimized formulation has greatly enhanced reagent stability. Cuvette or 96-well plate assay. Available format information for this listing includes 100 Tests in 96-well plate.\u003c\/p\u003e\n\n\u003ch2\u003eBiological background\u003c\/h2\u003e\n\u003cp\u003eThis product is centered on measurement of cobalt within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.\u003c\/p\u003e\n\n\u003ch2\u003eMore details\u003c\/h2\u003e\n\u003cp\u003eCobalt is an essential micronutrient for all multicellular organisms as the active center of cobalamin, such as vitamin B-12, which is essential for plants and animals. Cobalt is also a micronutrient for bacteria, algae, and fungi. Despite being an important micronutrient, excess cobalt in the environment can be deleterious to life leading to cardiomyopathy in humans and necrosis in plants.Simple, direct, and automation-ready procedures for measuring cobalt concentrations find wide applications in research and environmental monitoring. BioAssay Systems’ cobalt assay kit is designed to measure total cobalt directly in aqueous samples without any pretreatment. The intensity of the color, measured at 485nm, is directly proportional to the cobalt concentration in the sample.\u003c\/p\u003e\n\n\u003ch2\u003eDetection method\u003c\/h2\u003e\n\u003cp\u003eColorimetric (OD 485 nm).\u003c\/p\u003e\n\n\u003ch2\u003eDetection limit and analytical sensitivity\u003c\/h2\u003e\n\u003cp\u003eReported detection limit: 1.4µM.\u003c\/p\u003e\n\n\u003ch2\u003eProcedures and timing\u003c\/h2\u003e\n\u003cp\u003eStated procedure or timing information: 10 min.\u003c\/p\u003e\n\n\u003ch2\u003eResearch relevance and current trends\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePlate-based quantification and side-by-side group comparison remain central use cases for this assay format.\u003c\/li\u003e\n  \u003cli\u003eThe product notes emphasize multi-sample throughput, making it relevant for screening-oriented and larger batch comparison studies.\u003c\/li\u003e\n  \u003cli\u003eShort assay timing and plate compatibility support time-course or repeated-measure collection plans when handling is kept consistent.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCommon research applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eQuantify cobalt in aqueous samples by OD485 nm readout.\u003c\/li\u003e\n  \u003cli\u003eCompare treatment or phenotype groups using matched aqueous samples handling.\u003c\/li\u003e\n  \u003cli\u003eMonitor time-course or pre\/post changes in aqueous samples across study conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInterpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.\u003c\/p\u003e\n\n\u003ch2\u003eNotes for experimental interpretation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMatrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.\u003c\/li\u003e\n  \u003cli\u003eUse appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Sources (internal):\n- Product Description column\n- Key Features column\n- More Details column\n- Method \/ Sample Type(s) \/ Assay Time \/ Detection Limit \/ Detection Method columns\n- Procedures column\n- Screening Services column\n--\u003e","brand":"BioAssay Systems","offers":[{"title":"100 Tests in 96-well plate","offer_id":53238314631533,"sku":"DCBT-100","price":549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/DCBTfig.jpg?v=1776668351","url":"https:\/\/www.ebiohippo.com\/products\/quantichrom-cobalt-assay-kit-bht15600030","provider":"BioHippo","version":"1.0","type":"link"}