{"product_id":"quantichrom-salicylate-assay-kit-bht15600088","title":"QuantiChrom™ Salicylate Assay Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eFor quantitative determination of salicylate in biological samples and beauty products, mouthwash, etc. The assay uses OD560nm for signal readout. Compatible sample input includes Serum, plasma, urine, food, beverage, agriculture, drugs, beauty, mouthwash samples, etc. Typical stated assay timing is 30 min.\u003c\/p\u003e\n\n\u003ch2\u003eKey elements and design rationale\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReadout format:\u003c\/strong\u003e OD560nm supports plate-based signal acquisition and consistent comparison across matched samples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSample compatibility:\u003c\/strong\u003e The stated sample scope includes Serum, plasma, urine, food, beverage, agriculture, drugs, beauty, mouthwash samples, etc, which is useful when aligning matrix type with calibration and control design.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorkflow timing:\u003c\/strong\u003e The listed assay time of 30 min helps frame batch planning, replicate handling, and plate throughput.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeature emphasis:\u003c\/strong\u003e Fast and sensitive. Linear detection range: 0.8 mM (10.9 mg\/dL) to 20 mM (274.2 mg\/dL) salicylate with 20 µL sample (96-well).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional feature notes highlight Convenient. The procedure involves adding a single working reagent; High-throughput. “Add-mix-read” type assay. Can be readily automated as a high-throughput 96-well or 384-well plate assay for thousands of samples per day. Available format information for this listing includes 100 Tests.\u003c\/p\u003e\n\n\u003ch2\u003eBiological background\u003c\/h2\u003e\n\u003cp\u003eThis product is centered on measurement of salicylate within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.\u003c\/p\u003e\n\n\u003ch2\u003eMore details\u003c\/h2\u003e\n\u003cp\u003e\u003ci\u003eSALICYLATE\u003c\/i\u003eis a salt or ester of salicylic acid and can be found naturally in some plants. It is also a metabolic byproduct of aspirin (acetylsalicylic acid) and salicylate concentrations are often tested in blood or urine in cases of suspected overdose. Salicylic acid is commonly used in skincare products as an exfoliating ingredient and in other consumer products as a preservative. BioAssay Systems’ salicylate detection kit provides a convenient and reliable means to measure salicylate. In the assay, salicylate complexes with ferric chloride create a colored compound that can be measured at 560 nm. This assay can be used with a variety of samples and is simple, sensitive, and adaptable to high-throughput screening.\u003c\/p\u003e\n\n\u003ch2\u003eDetection method\u003c\/h2\u003e\n\u003cp\u003eColorimetric (OD 560 nm).\u003c\/p\u003e\n\n\u003ch2\u003eProcedures and timing\u003c\/h2\u003e\n\u003cp\u003eStated procedure or timing information: 30 min.\u003c\/p\u003e\n\n\u003ch2\u003eResearch relevance and current trends\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePlate-based quantification and side-by-side group comparison remain central use cases for this assay format.\u003c\/li\u003e\n  \u003cli\u003eThe product notes emphasize multi-sample throughput, making it relevant for screening-oriented and larger batch comparison studies.\u003c\/li\u003e\n  \u003cli\u003eThe description supports intervention-focused study designs in which researchers compare baseline and perturbed conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCommon research applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eQuantify salicylate in serum, plasma, urine by OD560 nm readout.\u003c\/li\u003e\n  \u003cli\u003eCompare treatment or phenotype groups using matched serum, plasma, urine handling.\u003c\/li\u003e\n  \u003cli\u003eMonitor time-course or pre\/post changes in serum, plasma, urine across study conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInterpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.\u003c\/p\u003e\n\n\u003ch2\u003eNotes for experimental interpretation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMatrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.\u003c\/li\u003e\n  \u003cli\u003eUse appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- Sources (internal):\n- Product Description column\n- Key Features column\n- More Details column\n- Method \/ Sample Type(s) \/ Assay Time \/ Detection Limit \/ Detection Method columns\n- Procedures column\n- Screening Services column\n--\u003e","brand":"BioAssay Systems","offers":[{"title":"100 Tests","offer_id":53238313025901,"sku":"DSALY-100","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0949\/7424\/7277\/files\/DSALYfig.jpg?v=1776668351","url":"https:\/\/www.ebiohippo.com\/products\/quantichrom-salicylate-assay-kit-bht15600088","provider":"BioHippo","version":"1.0","type":"link"}