Uncoated Human TSP-2 (Thrombospondin-2) ELISA Kit

SKU:BHE10309750
Suppliers
Elabscience Biotechnology Co Ltd
Elabscience Biotechnology Co Ltd
Details Products
Overview
Click light‑blue chips for details
TSP-2 (Human) ELISA kit for quantitative measurement, in serum, plasma (Sandwich format). HRP-colorimetric detection with standard-curve quantification.
Assay Type Sandwich ELISA
Sample Type Serum
Detection Range 31.25-2000 pg/mL
Species Human
Assay Time 24 h
Detection Method Colorimetric (TMB/HRP)
Options selector
Catalog no. Size
E-UNEL-H0355_96T*5 96 T x 5
E-UNEL-H0355_96T*15 96 T x 15
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size (2) - 96 T x 5, 96 T x 15
  • Lead time: varies by selected option.
  • Storage: -20℃,12 months
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: store at the recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No E-UNEL-H0355
Assay Time
  • 24 h
Detection Method
  • Colorimetric method
  • ELISA
  • Sandwich
Detection Range 31.25-2000 pg/mL
Product Type
  • Sandwich ELISA Kit
Shipping Ice packs
Storage -20℃,12 months
UniProt # P35442

Scientific Background

This ELISA kit applies to the in vitro quantitative determination of Human TSP-2 concentrations in serum, plasma and other biological fluids.

Assay Principle

This Sandwich ELISA Kit uses a two-site sandwich immunoassay format. A capture antibody specific to TSP-2 is pre-coated on the microplate. Standards and samples are added and any TSP-2 present is captured. A biotinylated detection antibody is added, followed by Streptavidin–HRP conjugate. TMB substrate produces color proportional to TSP-2 concentration; the reaction is stopped and absorbance read at 450 nm. Sample concentrations are interpolated from a standard curve.

Performance Specifications

Detection Range 31.25-2000 pg/mL
Total Assay Time 24 h
Compatible Sample Types Serum, plasma
Species Reactivity Human
Detection Method Sandwich
Precision (CV) Both intra-CV and inter-CV are < 10%.
Recovery Rate 80%-120%
Storage -20℃,12 months

✓ Research-Grade Validation

Specificity

This kit recognizes Human TSP-2 in samples. No significant cross-reactivity or interference between Human TSP-2 and analogues was observed

Safety & Regulatory

Research Use Only (RUO). This product is intended for research purposes only and is not approved for diagnostic, therapeutic, or clinical use.

Handle reagents in accordance with institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for complete hazard and handling information. Contains components that may require special disposal procedures per local regulations.

What sample types are compatible with this TSP-2 ELISA kit?

This kit is validated for use with Serum, plasma. For unlisted matrices (e.g., tissue lysate, urine), perform a spike-and-recovery experiment to confirm assay performance before generating reportable data. Sample dilution in the kit's provided diluent is recommended to minimize matrix interference.

What is the detection limit for TSP-2?

The minimum detectable concentration (sensitivity) of this kit is specified in the kit datasheet. Values below this threshold should be reported as below the limit of detection (<LOD) and should not be extrapolated from the standard curve.

How long does the complete assay take?

The total assay time from sample addition to absorbance reading is approximately 24 h, including all incubation, wash, and substrate steps. Hands-on time is typically 1–2 hours; most steps involve passive plate incubation. Plan the assay as a single uninterrupted session for best results.

What reagents and materials are included in the kit?

Standard components of this Sandwich ELISA Kit typically include: pre-coated microplate (96-well strip format), lyophilized or liquid recombinant TSP-2 standard, detection antibody, streptavidin-HRP conjugate, TMB substrate, stop solution, wash buffer concentrate, and sample/standard diluent. Refer to the kit insert or datasheet for the exact component list and storage requirements.

What instrument is required to read the assay?

This kit uses colorimetric (TMB/HRP) detection and requires a standard microplate absorbance reader capable of measuring at 450 nm. A reference wavelength of 570 nm or 630 nm is recommended to reduce background. No specialized fluorescence or luminescence reader is needed. Ensure the instrument is calibrated and the plate is clean and free of condensation before reading.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today