| Field | Specification |
|---|---|
| Mfr No | |
| Alternative Names | A2AP; AAP; ALPHA-2-PI; API; PLI; OTTHUMP00000115656|alpha-2-antiplasmin|alpha-2-plasmin inhibitor|serine (or cysteine) proteinase inhibitor; clade F (alpha-2 antiplasmin; pigment epithelium derived |
| Product Type | |
| Sensitivity |
Scientific Background
An inherited hemorrhagic diathesis due to plasmin inhibitor deficiency was described by Koie et al. (1978) in a 25-year-old Okinawa man. He had suffered prolonged bleeding and ecchymoses after minor trauma, spontaneous joint hemorrhage, and one episode of hemothorax. The bleeding episodes were reduced in frequency and severity by an antiplasminic drug. Laboratory abnormalities were limited to shortened euglobulin-lysis time and whole blood clot lysis time. No circulating alpha-2-plasmin inhibitor was found in the plasma. Even though only one case was observed, autosomal recessive inheritance w.
Assay Principle
This assay employs a two-site sandwich ELISA to quantitate SERPINF2 in samples. An antibody specific for SERPINF2 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anySERPINF2 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for SERPINF2 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of SERPINF2 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Performance Specifications
| Sensitivity | 0.69 ng/mL |
|---|---|
| Detection Range | 1.56-100 ng/mL |
| Total Assay Time | 3.5–5 hours |
| Compatible Sample Types | serum, plasma, cell culture supernatant, tissue homogenate |
| Species Reactivity | Human |
| Detection Method | Colorimetric (TMB/HRP) |
| Storage | 4°C (short-term); -20°C (long-term) |
✓ Research-Grade Validation
Safety & Regulatory
Handle reagents in accordance with institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for complete hazard and handling information. Contains components that may require special disposal procedures per local regulations.
This kit is validated for use with serum, plasma, cell culture supernatant, tissue homogenate. For unlisted matrices (e.g., tissue lysate, urine), perform a spike-and-recovery experiment to confirm assay performance before generating reportable data. Sample dilution in the kit's provided diluent is recommended to minimize matrix interference.
The minimum detectable concentration (sensitivity) of this kit is 0.69 ng/mL. Values below this threshold should be reported as below the limit of detection (<LOD) and should not be extrapolated from the standard curve.
The total assay time from sample addition to absorbance reading is approximately 3.5–5 hours, including all incubation, wash, and substrate steps. Hands-on time is typically 1–2 hours; most steps involve passive plate incubation. Plan the assay as a single uninterrupted session for best results.
Standard components of this Sandwich ELISA Kit typically include: pre-coated microplate (96-well strip format), lyophilized or liquid recombinant SERPINF2 standard, detection antibody, streptavidin-HRP conjugate, TMB substrate, stop solution, wash buffer concentrate, and sample/standard diluent. Refer to the kit insert or datasheet for the exact component list and storage requirements.
This kit uses colorimetric (TMB/HRP) detection and requires a standard microplate absorbance reader capable of measuring at 450 nm. A reference wavelength of 570 nm or 630 nm is recommended to reduce background. No specialized fluorescence or luminescence reader is needed. Ensure the instrument is calibrated and the plate is clean and free of condensation before reading.
Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.