Human IGF-1 (Insulin-Like Growth Factor 1) ELISA Kit

SKU:BHE10804879
Overview
Click light‑blue chips for details
Quantitative double-antibody sandwich ELISA kit for measuring human IGF-1 (Insulin-Like Growth Factor 1) in Serum, Plasma, Cell Culture Supernatant, and cell or tissue lysate. Includes sensitivity 37.5pg/mL, detection range 62.5–4000pg/mL for signal transduction research. Includes assay time 4 hours.
Target IGF-1
Species Human
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Assay Type Sandwich ELISA, Double Antibody
Sensitivity 37.5pg/ml
Detection Range 62.5-4000pg/ml
Assay Time 4 hours
Options selector
Catalog no. Size
EH0165-96T 96 T
Available Options

Select the variant options shown for this product and review lead time and shipping expectations before ordering.

  • Size: 96 tests (96T) kit.
  • Lead time: options listed as “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: 2-8 °C for 12 months; ships cold (typically with ice packs) is expected.
  • Please ensure someone is available to receive and store the shipment promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No EH0165
Alternative Names Insulin-like growth factor I|IGF-I|Mechano growth factor|MGF|Somatomedin-C|IGF1|IBP1
Assay Time
  • 4 hours
Detection Method
  • Sandwich ELISA
  • Double Antibody
Detection Range 62.5-4000pg/ml
Product Type
  • ELISA Kits
Reactivity
  • Human
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Sensitivity 37.5pg/ml
Species Human
Storage 2-8 °C for 12 months
Target IGF-1
UniProt # P05019

Background

human IGF-1 (Insulin-Like Growth Factor 1) is a molecular target commonly studied in signal transduction, metabolism, and immunology research. Growth factors are signaling proteins that influence proliferation, differentiation, and tissue remodeling through receptor activation.

Biological role and mechanism

The biological role of IGF-1 is typically understood in terms of its molecular category and interaction network. Depending on the model system, it may participate in cell–cell communication, intracellular signaling, enzymatic processing, or regulation of gene expression programs. Mechanistic interpretation is often strengthened by considering upstream regulators and downstream readouts rather than relying on a single marker.

Expression and abundance of IGF-1 can vary by tissue, cell type, and physiological state. In many systems, levels are influenced by factors such as developmental stage, immune activation, metabolic status, and cellular stress. Because sample matrix and pre-analytical handling can affect measured concentrations, interpretation is typically strongest when experiments keep collection and processing consistent across groups.

Nomenclature and related terms

IGF-1 (Insulin-Like Growth Factor 1) may also be referenced as Insulin-like growth factor I, IGF-I, and Mechano growth factor in the literature or in databases. When comparing results across studies, confirm that the reported analyte refers to the same molecule, species context, and molecular form (e.g., precursor vs mature protein, or soluble vs membrane-associated forms).

Why it matters in research

  • Understanding how IGF-1 relates to energy homeostasis, glucose and lipid metabolism, insulin sensitivity and endocrine regulation, and adipose–liver crosstalk in signal transduction, metabolism, and immunology research.
  • Interpreting shifts in IGF-1 levels alongside other pathway components or complementary markers.
  • Connecting molecular changes to phenotypes such as inflammation, remodeling, metabolism shifts, or cell-state transitions (context-dependent).

Molecular forms and interpretation

For some targets, isoforms, proteolytic processing, or post-translational modifications (such as phosphorylation or glycosylation) can influence function and apparent abundance. If multiple molecular forms are expected in your model, align interpretation with the form most relevant to the biological question.

Disease and translational relevance

IGF-1 has been investigated across diverse physiological and disease contexts, and changes in its abundance have been reported in areas aligned with signal transduction, metabolism, and immunology studies. These associations are interpreted as research findings rather than diagnostic or therapeutic claims, and they should be evaluated alongside model-specific covariates and study design.

?What?s the plate size in FineTest? ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
?How about the shelf life and stability of FineTest? ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest? ELISA Kits have been subject to strict quality test.
?Which cloned antibodies for FineTest? ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
?Can I mix reagents from different batches of FineTest? ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
?Can FineTest? ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
?How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
?Can standard curve be extended to any direction?
FineTest? can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
?Why does detection for serum/plasma sample by FineTest? ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
?What?s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest? can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
?What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Chemosensory and cardiometabolic improvements after a fasting-mimicking diet: A randomized cross-over clinical trial

IF: 11.7 Journal: Cell Reports Medicine Author: Unit of Neuroscience, Rehabilitation and Sensory Organs, UNITER ONLUS, Rome, Italy. Cited Date: 2025-02-28

Permanent Pro-Tumorigenic Shift in Adipose Tissue-Derived Mesenchymal Stromal Cells Induced by Breast Malignancy

IF: 5.656 Journal: Cells Cited Date: 2020-03-01

The impact of local and systemic penicillin on antimicrobial properties and growth factor release in platelet-rich fibrin: In vitro study

IF: 3.4 Journal: Clinical Oral Investigations Author: Department of Periodontology, Faculty of Dentistry, Cukurova University, Adana, Turkey Cited Date: 2024-01-26

Prognostic Value of Serum Insulin‐Like Growth Factor‐1 in Patients With Anal Fistula Treated by Incision‐Thread‐Drawing Surgery

IF: 3.3 Journal: Annals of Gastroenterological Surgery Author: Department of Traditional Chinese Medicine, Zibo Central Hospital, Zibo, Shandong, China Cited Date: 2025-10-17

NNMT Enhances Invasive and Migratory Capacity of Keloid Fibroblasts and M2 Macrophage Polarization

IF: 3 Journal: Archives of Biochemistry and Biophysics Author: Department of Plastic Surgery, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, People's Republic of China. Cited Date: 2025-08-22

L-Ascorbic Acid (LAA) Supplementation as a Potential Treatment for Skin Aging: Regulation of Adipose Tissue Mesenchymal Stem Cells (AT-MSCs) Protein Secretion

IF: 3 Journal: Current Issues in Molecular Biology Author: Doctoral Program, Faculty of Medicine, Udayana University, Denpasar, Bali 80232, Indonesia Cited Date: 2025-06-27

Systemic Responses Towards Oxy-Inflammation, Hormones, and Mood in Breast Cancer Survivors: Preliminary Evidences from Dragon Boat Endurance Race

IF: 3 Journal: Journal of Clinical Medicine Author: Department of Human Sciences and Promotion of the Quality of Life, San Raffaele Roma Open University, 00166 Roma, Italy. Cited Date: 2025-04-18

Environmental study and stress-related biomarkers modifications in a crew during analog astronaut mission EMMPOL 6

IF: 2.8 Journal: European Journal of Applied Physiology Author: Department of Biomedical Sciences, University of Padova, Via Marzolo 3, 35131, Padua, Italy. Cited Date: 2024-10-08

Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today