Human S100 calcium binding protein A8/A9, S100A8/A9 ELISA Kit

SKU:BHE12115841
Catalog / Quick links
    Overview
    Click light‑blue chips for details
    Quantitative sandwich ELISA kit for measuring human S100A8/A9 in Serum, Plasma, Urine, and Ascites. Key specs include sensitivity 0.32 ng/L, detection range 0.5–200ng/L, assay time 1 h 30m, supporting reproducible quantification in immunology research across time-course and treatment studies.
    Target S100A8/A9
    Species Human
    Reactivity Human
    Sample Type(s) Serum, Plasma, Urine, Ascites, Cerebrospinal fluid, Tissue
    Assay Type Sandwich
    Sensitivity 0.32ng/L
    Detection Range 0.5-200ng/L
    Assay Time 1h 30m
    Available Options

    Select from the available variant options shown for this product. Review lead time and shipping expectations before ordering.

    • Options: Size (48 tests (48T), 96 tests (96T)).
    • Lead time: typically ships in 5–7 business days; processing time may vary by selected option.
    • Storage: store at 2-8°C; ships cold (typically with ice packs) is expected.
    • Please ensure someone is available to receive and store the shipment promptly.
    • Sales terms and conditions: Please review prior to ordering.
    Options selector
    Catalog no. Size
    E4465Hu-96T 96T
    E4465Hu-48T 48T
    Field Specification
    Alternative Names S100A8;CAGA;CFAG;MRP8
    Assay Time
    • 1h 30m
    Assay Type
    • Sandwich
    Detection Range 0.5-200ng/L
    Gene ID 6279
    Product Type
    • ELISA Kits
    Reactivity
    • Human
    Sample Type(s) Serum, Plasma, Urine, Ascites, Cerebrospinal fluid, Tissue
    Sensitivity 0.32ng/L
    Species Human
    Storage 2-8°C
    Target S100A8/A9
    UniProt # P05109

    Background

    S100A8/A9 is a molecular target commonly studied in immunology, signal transduction, and cell biology research. This molecule is commonly investigated as part of broader signaling, regulatory, or homeostatic networks.

    UniProt: P05109

    Biological role and pathway context

    In the literature, S100A8/A9 is frequently examined in relation to innate and adaptive immune responses, cytokine signaling networks, and immune cell activation and trafficking. Depending on the model system, changes in abundance can be associated with shifts in signaling state, cellular composition, or tissue physiology.

    Expression and regulation

    Expression of S100A8/A9 can vary across tissues and cell types and may change under conditions such as immune activation, stress responses, injury, infection, or metabolic perturbation. Reported regulation may involve transcriptional control as well as post-translational processes that influence stability, localization, processing, or secretion.

    Research and disease relevance

    S100A8/A9 has been reported as a useful readout in studies of physiological regulation and disease-associated processes. These observations make it relevant for hypothesis-driven research and biomarker exploration, while interpretation should remain grounded in the specific species, sample matrix, and study design.

    Interpreting concentration measurements

    Measured levels of S100A8/A9 can reflect multiple biological factors, including production rate, turnover, compartmental distribution, and sample composition. As a result, conclusions are often supported by considering broader pathway context and complementary readouts rather than relying on a single analyte alone.

    Nomenclature

    S100A8/A9 may also be referred to as S100A8, CAGA, and CFAG in publications and databases. Nomenclature differences and species context can influence how results are compared across studies.

    What is a sample matrix effect?

    Matrix effects refer to the influence that other substances in your sample have on the detection of your specific target protein. They are most commonly observed with plasma and serum samples, where matrix components can interfere with antibody–antigen binding or alter the signal-to-noise ratio. If a matrix effect is suspected, perform a spike-and-recovery experiment and a dilution linearity test to confirm assay accuracy before reporting results.

    Why is there no signal in my sample when the standard curve looks good?

    Several causes can produce a valid standard curve but no measurable signal in samples:

    • The sample was prepared incorrectly and may not contain the target analyte at a detectable level.
    • A matrix effect is masking or suppressing detection — run a spike-and-recovery test to check.
    • The sample or a kit antibody component may be contaminated or degraded.
    • Analyte concentrations may exceed the assay range — select a kit with an appropriate dynamic range, or dilute the sample.
    How much sample volume is required for a BT Lab sandwich ELISA kit?

    BT Lab sandwich ELISA kits require 40 µL of sample per well. Always refer to the specific product datasheet for any exceptions, as sample volume requirements can vary by assay format.

    Can I use a protein standard from another manufacturer with this kit?

    No. We do not recommend mixing reagents from different ELISA kits or manufacturers. The calibrators, capture antibodies, and detection antibodies in BT Lab kits are matched and validated as a system. Substituting components from other sources can compromise assay accuracy and reproducibility, and voids the kit's performance guarantee.

    What sample types are validated for use with this kit?

    BT Lab kits are generally validated for serum, plasma, and cell culture supernatant. However, validated sample types vary by product — please consult the specific product datasheet and product page for confirmed matrices. Published literature may support additional sample types (e.g., tissue homogenate, urine, CSF), but independent validation is recommended before using non-listed matrices in your study.

    Can I use the ELISA plate partially and save the unused wells?

    Yes. BT Lab ELISA plates feature removable 8-well strip modules. Unused strips can be detached, returned to the original foil pouch with the desiccant, resealed, and stored at 2–8 °C for up to one month. Avoid exposing unused strips to moisture or direct light during storage.

    What is the shelf life of BT Lab ELISA kits?

    BT Lab kits are guaranteed to be stable until the expiration date printed on the label, provided they are stored and handled under the conditions specified in the product datasheet. For recombinant proteins, the minimum guaranteed shelf life is 12 months from the date of receipt by the end-user. Do not use any components beyond their expiration date.

    Can?t Find What You?re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

    Get a Quote

    Please use this form for bulk quantity requests or customized products.

    Contact Information

    Product Information

    Supplier Ads Slides show

    Add dynamic ads with slider