Human sICAM-1/CD54 (Soluble Intercellular Adhesion Molecule 1) ELISA Kit

SKU:BHE10802694
Overview
Click light‑blue chips for details
Quantitative double-antibody sandwich ELISA kit for measuring human sICAM-1/CD54 (Soluble Intercellular Adhesion Molecule 1) in Serum, Plasma, Cell Culture Supernatant, and cell or tissue lysate. Includes sensitivity 0.469ng/mL, detection range 0.781–50ng/mL for stem cells research.
Target sICAM-1/CD54
Species Human
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Assay Type Sandwich ELISA, Double Antibody
Sensitivity 0.469ng/ml
Detection Range 0.781-50ng/ml
Assay Time 4 hours
Options selector
Catalog no. Size
EH0161-96T 96 T
Available Options

Select the variant options shown for this product and review lead time and shipping expectations before ordering.

  • Size: 96 tests (96T) kit.
  • Lead time: options listed as “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: 2-8 °C for 12 months; ships cold (typically with ice packs) is expected.
  • Please ensure someone is available to receive and store the shipment promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No EH0161
Alternative Names Intercellular adhesion molecule 1|ICAM-1|Major group rhinovirus receptor|ICAM1
Assay Time
  • 4 hours
Detection Method
  • Sandwich ELISA
  • Double Antibody
Detection Range 0.781-50ng/ml
Product Type
  • ELISA Kits
Reactivity
  • Human
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Sensitivity 0.469ng/ml
Species Human
Storage 2-8 °C for 12 months
Target sICAM-1/CD54
UniProt # P05362

Background

human sICAM-1/CD54 (Soluble Intercellular Adhesion Molecule 1) is a molecular target commonly studied in stem cells, immunology, and cardiovascular research. Many proteins are studied as molecular readouts that can change with cellular state, tissue remodeling, or stress responses.

Biological role and mechanism

The biological role of sICAM-1/CD54 is typically understood in terms of its molecular category and interaction network. Depending on the model system, it may participate in cell–cell communication, intracellular signaling, enzymatic processing, or regulation of gene expression programs. Mechanistic interpretation is often strengthened by considering upstream regulators and downstream readouts rather than relying on a single marker.

Expression and abundance of sICAM-1/CD54 can vary by tissue, cell type, and physiological state. In many systems, levels are influenced by factors such as developmental stage, immune activation, metabolic status, and cellular stress. Because sample matrix and pre-analytical handling can affect measured concentrations, interpretation is typically strongest when experiments keep collection and processing consistent across groups.

Nomenclature and related terms

sICAM-1/CD54 (Soluble Intercellular Adhesion Molecule 1) may also be referenced as Intercellular adhesion molecule 1, ICAM-1, and Major group rhinovirus receptor in the literature or in databases. When comparing results across studies, confirm that the reported analyte refers to the same molecule, species context, and molecular form (e.g., precursor vs mature protein, or soluble vs membrane-associated forms).

Why it matters in research

  • Understanding how sICAM-1/CD54 relates to innate and adaptive immune responses, cytokine signaling networks, host–pathogen interactions, and immune cell activation and trafficking in stem cells, immunology, and cardiovascular research.
  • Interpreting shifts in sICAM-1/CD54 levels alongside other pathway components or complementary markers.
  • Connecting molecular changes to phenotypes such as inflammation, remodeling, metabolism shifts, or cell-state transitions (context-dependent).

Molecular forms and interpretation

For some targets, isoforms, proteolytic processing, or post-translational modifications (such as phosphorylation or glycosylation) can influence function and apparent abundance. If multiple molecular forms are expected in your model, align interpretation with the form most relevant to the biological question.

Disease and translational relevance

sICAM-1/CD54 has been investigated across diverse physiological and disease contexts, and changes in its abundance have been reported in areas aligned with stem cells, immunology, and cardiovascular studies. These associations are interpreted as research findings rather than diagnostic or therapeutic claims, and they should be evaluated alongside model-specific covariates and study design.

?What?s the plate size in FineTest? ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
?How about the shelf life and stability of FineTest? ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest? ELISA Kits have been subject to strict quality test.
?Which cloned antibodies for FineTest? ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
?Can I mix reagents from different batches of FineTest? ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
?Can FineTest? ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
?How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
?Can standard curve be extended to any direction?
FineTest? can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
?Why does detection for serum/plasma sample by FineTest? ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
?What?s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest? can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
?What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Are Selected Cytokines and Epstein–Barr Virus DNA Load Predictors of Hepatological Complications of Epstein–Barr Virus Infection in Children?

IF: 3.9 Journal: Journal of Clinical Medicine Author: Department of Infectious Diseases and Hepatology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, 87-100 Toruń, Poland Cited Date: 2023-09-28

Treatment of Class II Malocclusion With Orthodontic Microimplant Anchorage

IF: 3.3 Journal: International Dental Journal Author: Dental Clinic, Cangzhou Central Hospital, Cangzhou, Hebei, China Cited Date: 2023-12-15

Atorvastatin ameliorates chronic subdural hematomas by interrupting the 'chronic subdural hematoma cycle'via inhibition of the inflammatory response

IF: 2.3 Journal: Experimental and Therapeutic Medicine Author: Department of Critical Care Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710061, P.R. China. Cited Date: 2025-11-28

Assessment of Serum Endocan and sICAM-1 Levels as Markers of Endothelial Dysfunction and Systemic Inflammation and Their Relationship with Comorbidities in COPD Patients

IF: Journal: Journal of Izmir Chest Hospital Cited Date: 2021-05-06

The Influence of Obstructive Sleep Apnea/Hypopnea Syndrome on the Levels of Proinflammatory and Profibrotic Cytokines in Patients with Gastroesophageal Reflux Disease

IF: Journal: Health and environmental issues Cited Date: 2019-08-15

The concentration of IL-6, TNF-α, s-ICAM-1, and EBV DNA load – predictive factors of hepatological complications in children with infectious mononucleosis. A pilot study

IF: Journal: Polish Journal of Paediatrics Cited Date: 2023-03-31

Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today