Human Sodium- and chloride-dependent taurine transporter (SLC6A6/TAUT) ELISA Kit

SKU:BHE11401647
Overview
Click light‑blue chips for details
SLC6A6 (Human) ELISA kit for quantitative measurement, in serum, plasma, cell culture supernatant (Sandwich format). HRP-colorimetric detection with standard-curve quantification. Sensitivity: 0.056 ng/mL.
Assay Type Sandwich ELISA
Sample Type serum
Sensitivity 0.056 ng/mL
Detection Range 0.156-10 ng/mL
Species Human
Assay Time 3.5–5 hours
Detection Method Colorimetric (TMB/HRP)
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size (2) - 48 T, 96 T
  • Lead time: varies by selected option.
  • Storage: 4°C (short-term); -20°C (long-term)
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: store at the recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Options selector
Catalog no. Size
AE18367HU-48T 48 T
AE18367HU-96T 96 T
Field Specification
Alternative Names MGC10619; MGC131729; TAUT;
Product Type
  • Sandwich ELISA Kit
Sensitivity 0.056 ng/mL
UniProt # P31641

Scientific Background

Taurine (2-aminoethanesulfonic acid) is a major intracellular amino acid in mammals. It is involved in a number of important physiologic processes, including bile acid conjugation in hepatocytes, modulation of calcium flux and neural excitability, osmoregulation, detoxification, and membrane stabilization. The cells of most organisms respond to hypertonicity by the intracellular accumulation of high concentrations of small organic solutes (osmolytes) that, in contrast to high concentrations of electrolytes, do not perturb the function of macromolecules. The renal medulla is normally the only t.

Assay Principle

This assay employs a two-site sandwich ELISA to quantitate SLC6A6 in samples. An antibody specific for SLC6A6 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anySLC6A6 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for SLC6A6 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of SLC6A6 bound in the initial step. The color development is stopped and the intensity of the color is measured.

Performance Specifications

Sensitivity 0.056 ng/mL
Detection Range 0.156-10 ng/mL
Total Assay Time 3.5–5 hours
Compatible Sample Types serum, plasma, cell culture supernatant, tissue homogenate
Species Reactivity Human
Detection Method Colorimetric (TMB/HRP)
Storage 4°C (short-term); -20°C (long-term)

✓ Research-Grade Validation

Safety & Regulatory

Research Use Only (RUO). This product is intended for research purposes only and is not approved for diagnostic, therapeutic, or clinical use.

Handle reagents in accordance with institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for complete hazard and handling information. Contains components that may require special disposal procedures per local regulations.

What sample types are compatible with this SLC6A6 ELISA kit?

This kit is validated for use with serum, plasma, cell culture supernatant, tissue homogenate. For unlisted matrices (e.g., tissue lysate, urine), perform a spike-and-recovery experiment to confirm assay performance before generating reportable data. Sample dilution in the kit's provided diluent is recommended to minimize matrix interference.

What is the detection limit for SLC6A6?

The minimum detectable concentration (sensitivity) of this kit is 0.056 ng/mL. Values below this threshold should be reported as below the limit of detection (<LOD) and should not be extrapolated from the standard curve.

How long does the complete assay take?

The total assay time from sample addition to absorbance reading is approximately 3.5–5 hours, including all incubation, wash, and substrate steps. Hands-on time is typically 1–2 hours; most steps involve passive plate incubation. Plan the assay as a single uninterrupted session for best results.

What reagents and materials are included in the kit?

Standard components of this Sandwich ELISA Kit typically include: pre-coated microplate (96-well strip format), lyophilized or liquid recombinant SLC6A6 standard, detection antibody, streptavidin-HRP conjugate, TMB substrate, stop solution, wash buffer concentrate, and sample/standard diluent. Refer to the kit insert or datasheet for the exact component list and storage requirements.

What instrument is required to read the assay?

This kit uses colorimetric (TMB/HRP) detection and requires a standard microplate absorbance reader capable of measuring at 450 nm. A reference wavelength of 570 nm or 630 nm is recommended to reduce background. No specialized fluorescence or luminescence reader is needed. Ensure the instrument is calibrated and the plate is clean and free of condensation before reading.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Supplier Ads Slides show

Add dynamic ads with slider