| Field | Specification |
|---|---|
| Assay Type | |
| Detection Instrument(s) | HTRF®-certified Microplate Reader (e.g. Tecan M1000, Tecan Spark) |
| Detection Method | |
| Product Type | |
| Shipping | |
| Storage |
Background
Kras is a member of the RAS protein family, which are a class of small GTPases involved in cell signaling pathways. The Ras signaling pathway plays an important role in cell proliferation and differentiation. Conversion of Kras from the inactive GDP-bound state to the active GTP-bound state triggers the downstream effector and promotes cell growth. RAS genes are frequently mutated in various human tumors. These mutations block the GTPase activity of RAS and lock RAS in the GTP- bound state, resulting in constitutively active signals through the downstream cascades leading to cancer cell proliferation.
Assay Principle
The Kras (G13D) nucleotide exchange assay is a TR-FRET based assay. The assay kit is designed to detect the GTP binding status of Kras mutant (G13D). The Tag2-Kras (G13D) in this assay kit is recognized by a Terbium-labeled anti-Tag2 antibody (HTRF donor). If Kras binds to a fluorescence- labeled GTP (HTRF acceptor), the donor and the acceptor will be brought in close proximity. Excitation of Terbium (340 nm) generates fluorescence resonance energy transfer (FRET) to the fluorescence- labeled GTP acceptor, which consequently fluoresces at 665 nm (figure below). Thus, GTP binding to Kras can be quantitively measured by calculation of the fluorescent ratio of 665 nm/620 nm. The inhibitor blocking the nucleotide exchange will reduce the HTRF signal.
Application
High throughput screening of compounds that inhibit Kras activation for drug discovery. Aurora Biolabs LLC, San Diego, CA 92121; www.aurorabiolabs.com; 1
Instrument Required
A HTRF® certified microplate reader capable of measuring Time Resolved Fluorescence Resonance Energy Transfer (TR-FRET) is required.
Kit Components
| Catalog No. | Item | Amount | Storage |
|---|---|---|---|
| 5727-NK-B | 25 mL | -20°C | |
| 384-well microplate, White | Room temperature |
Materials Not Supplied
- Microplate reader, HTRF® certified microplate reader (such as Tecan M1000 or Tecan Spark, etc.)
- 0.5 M DTT
- Adjustable micro-pipettor
- Sterile Tips
Assay Protocol
- Step 1. Prepare 1X assay buffer containing 1 mM DTT (1X DTT-containing assay buffer) For example, mix 996 µl distilled water with 1000 µl of 2X assay Buffer (Catalogue number: 5727- NK-B) and 4 µl of 0.5 M DTT. Make only enough 1X DTT-containing assay buffer as needed for the assay. Store the remaining 2X assay buffer at -20°C.
- Step 2. Prepare the inhibitor compound solution
- Step 3. Prepare Kras solution Thaw Kras (G13D) protein on ice. Upon first thaw, briefly spin tube to recover the full contents at the bottom of the tube. Make aliquots of the enzyme for single use. Store remaining undiluted enzyme at -80°C. Note: Kras protein is sensitive to freeze/thaw cycles. Limit number freeze-thaw cycles for best results. Do not re-use the diluted protein. Dilute the Kras protein to 800-fold (1 µL Kras G13D + 799 µL 1X assay buffer containing DTT). Add 8 µl of diluted protein solution to the positive control and inhibitor test wells. Add 8 µl of 1X assay buffer containing DTT) to the negative control wells.
- Step 4. Add inhibitor Add 2 µl of diluted compound solution to each inhibitor test well. Add 2 µl of inhibitor solvent solution to each of negative and positive control well. Incubate at room temperature for 30 minutes (optional).
- Step 5. Prepare dye solution Dilute Terbium-labeled anti-Tag2 antibody 1:200 and dilute fluorescence-labeled GTP 1:40 in 1X DTT-containing assay buffer. For example: 1 µl of Terbium-labeled anti-Tag2 antibody + 5 µl of fluorescence-labeled GTP + 194 µl of 1X DTT-containing assay buffer. Add 10 µl of this dye mixture to each well.
- Step 6. Incubate the reaction at room temperature for 30 minutes.
- Step 7. Measure fluorescent intensity HTRF compatible microplate reader is needed to measure fluorescent intensity of the samples. Fluorescent intensity should be measured twice:
- Step 8. Excitation wavelength at 340 nm and emission at 620 nm.
- Step 9. Excitation wavelength at 340 nm and emission at 665 nm. Negative Control Positive Control Inhibitor Test
Data Analysis
HTRF = (Fluorescence at 665 nm / Fluorescence at 620 nm) × 10,000
% Activity = (S − N) / (P − N) × 100S = sample signal | P = positive control (100%) | N = negative control (0%)
Calculate the HTRF signal (ratio of the fluorescent intensity at 665 mm/620 mm) of each well. Calculate percentage activity In the absence of the compound (positive control), the sample signal (P) is defined as 100% activity. In the absence of enzyme (negative control), the sample signal (N) is defined as 0% activity. The percent activity in the presence of each compound is calculated according to the following equation: % activity = (S-N)/(P-N) X100, where S= the sample signal in the presence of the compound.
Assay Validation
Assay: Kras (G13D) Nucleotide Exchange Activity
▶▼What biological event does this assay detect?
This kit detects GTP loading (nucleotide exchange) of Kras G13D in the presence of SOS1 or related GEFs, using TR-FRET. It quantifies the GTP-bound (active) state of the GTPase, enabling screening of nucleotide exchange inhibitors.
▶▼What instrument or plate reader is required?
An HTRF®-certified microplate reader capable of Time-Resolved Fluorescence Resonance Energy Transfer (TR-FRET) measurements is required. Compatible readers include the Tecan Spark, Tecan M1000, BMG PHERAstar, and PerkinElmer EnVision. The reader must support dual-emission measurement at excitation 340 nm and emission at 620 nm and 665 nm.
▶▼How many reactions are included, and is bulk ordering available?
This kit is available in 384 reactions. Each reaction is conducted in a 384-well / 96-well format, making it directly compatible with standard liquid-handling robotics for HTS applications. For bulk orders or custom quantities, please contact BioHippo or submit a quote request — distributor pricing is available.
▶▼Has the assay performance been validated?
Yes. Aurora Biolabs validates each kit using reference compounds to confirm assay window, signal-to-background ratio, and reproducibility prior to release. Specific validation data are provided in the product datasheet. Users are encouraged to determine the Z′ factor under their own experimental conditions.
▶▼What are the storage and shipping requirements?
The kit ships on Dry Ice and should be stored at -80°C upon receipt. Individual components may have different storage requirements — please refer to the component table in the datasheet. Protein components are sensitive to freeze–thaw cycles; aliquot on first thaw and avoid repeated freeze–thaw.
Need a different assay kit format or extra support beyond the catalog item? We offer customization and add-on services for assay kits to better fit your target, workflow, and detection platform. Options may include assay format customization (biochemical, binding, or cell-based), detection method selection such as TR-FRET, fluorescence polarization, luminescence, or colorimetric readout, target-specific reagent development including recombinant proteins, conjugates, antibodies, substrates, tracers, and controls, as well as protocol optimization for sensitivity, specificity, signal window, and reproducibility. We can also support kit component adjustments, plate format and scale options, QC and validation packages, bulk or custom packaging, and related assay development services when a standard kit does not fully meet your needs. Click Talk to a Scientist to submit a request, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.
Research budgets are tight — we get it. That's why we've put together a fresh round of exclusive promotions designed to help you stock up on the reagents, kits, and consumables your lab depends on, without stretching your budget.
🔬 What's on offer right now:
10% Off Pre-Designed siRNA Sets — use code SIRNA10
20% Off Transmembrane Proteins — use code TM20
$50 Off All ELISA Kits — auto-applied at checkout (code ELISA50)
50% Off Lab Consumables + Free Shipping on orders $500+
15% Off Proteins from Trusted Suppliers — use code PROTEIN15
$99 Pipette Filler Promotion Package (reg. $236)
Save 10% on your first order of any R&D grade DENARASE® with code DENARASE10 at checkout.