Mouse Eosinophil cationic protein (ECP) ELISA Kit

SKU:BHE13706718
Research Validated
Overview
Click light‑blue chips for details
Mouse Eosinophil cationic protein (ECP) ELISA Kit quantifies Mouse Eosinophil cationic protein (ECP) in serum, plasma, and cell culture supernatants using a sandwich ELISA format. Includes all components for standard-curve based quantification.
Assay Format Sandwich ELISA
Detection Method Colorimetric (HRP-TMB)
Compatible Sample Types Cell Culture Supernatant, Serum, Plasma
Species Reactivity Mouse
Assay Time 3–5 Hours
Options selector
Catalog no. Size
KTE71563-48T 48 T
KTE71563-96T 96 T
KTE71563-96TX5 96 T×5
KTE71563-96TX50 96 T×50
Available Options
Size (4) - 48 T, 96 T, 96 T×5, 96 T×50
Field Specification
Mfr No KTE71563
Alternative Names ECP
Assay Time
  • Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Assay Type
  • Sandwich ELISA (quantitative)
Detection Method
  • Colorimetric
Product Type
  • Sandwich ELISA Kit
Reactivity
  • Mouse
Sample Type(s) Cell culture supernatants, Serum, Plasma, Other biological fluids
Shipping Gel pack with blue ice.
Storage The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.

Features & Benefits

Mouse Eosinophil cationic protein (ECP) ELISA Kit has high sensitivity and excellent specificity for detection of Mouse ECP. No significant cross-reactivity or interference between Mouse ECP and analogues was observed.

Background

Three immunization procedures were compared for the production of antibodies to the minor components of a complex E. coli protein (ECP) mixture: a conventional protocol and two methods that allow for the selective in vitro (cascade) or in vivo (passive) depletion of highly immunogenic proteins.An E. coli protein, designated ω, has been purified at least 1000-fold. Treatment of a eovalently closed DNA duplex containing negative superhelical turns with ω results in the loss of most of the superhelical turns. The loss of superhelical turns follows a gradual course rather than a one-hit mechanism. This reaction does not require a cofactor. No other change in the physical properties of the DNA could be detected. ω is capable of introducing a “swivel” reversibly into a DNA. A plausible mechanism is postulated.

What sample types are compatible with this ELISA kit?

This Eosinophil cationic protein (ECP) ELISA kit is validated for use with Cell culture supernatants, Serum, Plasma, Other biological fluids. Samples should be collected, processed, and stored correctly to preserve analyte integrity — avoid repeated freeze-thaw cycles and centrifuge to remove particulates before use. Dilute samples exceeding the kit's detection range using the supplied assay diluent. Hemolytic, icteric, or lipemic samples may affect assay performance and should be tested with caution.

What is the assay format and detection principle?

This is a sandwich ELISA kit employing an HRP (horseradish peroxidase)-conjugated secondary antibody paired with a TMB (3,3′,5,5′-tetramethylbenzidine) colorimetric substrate. In the sandwich format, the target analyte Eosinophil cationic protein (ECP) captured on the microplate surface is detected by the conjugated antibody, generating a colorimetric signal proportional to analyte concentration. The reaction is stopped and absorbance measured at 450 nm on a standard microplate reader.

How long does the complete assay take?

The complete protocol, from sample addition to final plate reading, requires approximately 3–5 hours. This includes two incubation periods (analyte binding and detection antibody steps), intermediate wash cycles to remove unbound material, 15–30 minutes of TMB substrate development, and final stop-solution addition before absorbance reading. Exact timing will vary with experience level and the number of samples processed in parallel.

What equipment and instruments are required?

Required equipment: (1) a microplate spectrophotometer capable of reading absorbance at 450 nm (reference wavelength 540–570 nm recommended for background correction); (2) precision single-channel or multichannel pipettes; (3) a plate washer or multichannel aspirator; (4) a microcentrifuge for sample clarification; and (5) a 37°C incubator or stable room-temperature environment. No fluorescence or luminescence reader is required — standard colorimetric plate readers are fully compatible with this kit.

Can this kit detect Eosinophil cationic protein (ECP) in species not listed in the specification?

This ELISA kit is formally validated for Mouse. Cross-reactivity with species not listed in the specification has not been independently characterized. Variability in protein sequence homology across species means that performance in unlisted species cannot be guaranteed without additional validation. For cross-species detection requirements or non-standard sample matrices, please contact BioHippo support or refer to the manufacturer's technical team for guidance.

Can't Find What You're Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Inhibition of TLR4 inhibits allergic responses in murine allergic rhinitis by regulating the NF‑κB pathway(KTE71563-1.5)

Author:Hangyu Xu, Hairong Shu, Jie Zhu, Jianxin Song Publication name:Experimental and Therapeutic Medicine IF:1.5

Matches this product
$50 OFF
$50 Off All ELISA Kits
Limited time ELISA50
15%OFF
15% Off Cancer Antibodies
Ends Sep 30 ONCO15
10% OFF
10% OFF CELL LINES-Limited-Time Offer
Ends Sep 30 CELL10
FREE SAMPLE
Free Sample – CellTrypase Recombinant Trypsin-Like Enzyme
Limited time offer – availa... FREESAMPLE
FREE SAMPLE
Free Sample – MycoFold™ Growth Factors
Limited time offer – availa... Request Free Sample

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today