| Field | Specification |
|---|---|
| Mfr No | |
| Accession Number | |
| Alternative Names | TNRC6C; FLJ20015; KIAA1582 |
| Assay Time | |
| Assay Type | |
| Detection Method | |
| Gene ID | |
| Product Type | |
| Reactivity | |
| Sample Type(s) | Cell culture supernatants, Serum, Plasma, Other biological fluids |
| Shipping | |
| Storage |
Features & Benefits
Mouse Trinucleotide repeat-containing gene 6C protein (TNRC6C) ELISA Kit has high sensitivity and excellent specificity for detection of Mouse TNRC6C. No significant cross-reactivity or interference between Mouse TNRC6C and analogues was observed.
Background
By sequencing clones obtained from a fetal brain cDNA library, Nagase et al. (2000) cloned TNRC6C, which they designated KIAA1582. The deduced 1,448-amino acid protein contains an RNA recognition motif and a ubiquitin-associated (UBA) domain. RT-PCR ELISA detected moderate expression in heart, kidney, testis, ovary, adult and fetal brain, and all specific adult brain regions examined. Low expression was detected in skeletal muscle, and no expression was detected in lung, liver, pancreas, spleen, and fetal liver.
Schneider et al. (2006) stated that the TNRC6C protein contains a glycine/tryptophan (GW)-rich N-terminal domain, followed by a UBA domain, a glutamine-rich region, and a C-terminal RNA recognition motif.
This Trinucleotide repeat-containing gene 6C protein (TNRC6C) ELISA kit is validated for use with Cell culture supernatants, Serum, Plasma, Other biological fluids. Samples should be collected, processed, and stored correctly to preserve analyte integrity — avoid repeated freeze-thaw cycles and centrifuge to remove particulates before use. Dilute samples exceeding the kit's detection range using the supplied assay diluent. Hemolytic, icteric, or lipemic samples may affect assay performance and should be tested with caution.
This is a sandwich ELISA kit employing an HRP (horseradish peroxidase)-conjugated secondary antibody paired with a TMB (3,3′,5,5′-tetramethylbenzidine) colorimetric substrate. In the sandwich format, the target analyte Trinucleotide repeat-containing gene 6C protein (TNRC6C) captured on the microplate surface is detected by the conjugated antibody, generating a colorimetric signal proportional to analyte concentration. The reaction is stopped and absorbance measured at 450 nm on a standard microplate reader.
The complete protocol, from sample addition to final plate reading, requires approximately 3–5 hours. This includes two incubation periods (analyte binding and detection antibody steps), intermediate wash cycles to remove unbound material, 15–30 minutes of TMB substrate development, and final stop-solution addition before absorbance reading. Exact timing will vary with experience level and the number of samples processed in parallel.
Required equipment: (1) a microplate spectrophotometer capable of reading absorbance at 450 nm (reference wavelength 540–570 nm recommended for background correction); (2) precision single-channel or multichannel pipettes; (3) a plate washer or multichannel aspirator; (4) a microcentrifuge for sample clarification; and (5) a 37°C incubator or stable room-temperature environment. No fluorescence or luminescence reader is required — standard colorimetric plate readers are fully compatible with this kit.
This ELISA kit is formally validated for Mouse. Cross-reactivity with species not listed in the specification has not been independently characterized. Variability in protein sequence homology across species means that performance in unlisted species cannot be guaranteed without additional validation. For cross-species detection requirements or non-standard sample matrices, please contact BioHippo support or refer to the manufacturer's technical team for guidance.
Can't Find What You're Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.