Sea Lion Tri-iodothyronine (T3) ELISA Kit

SKU:BHE11401207
Overview
Click light‑blue chips for details
T3 (Sea Lion) ELISA kit for quantitative measurement, in serum, plasma, cell culture supernatant (Sandwich format). HRP-colorimetric detection with standard-curve quantification. Sensitivity: Request Information.
Assay Type Sandwich ELISA
Sample Type serum
Sensitivity Request Information
Detection Range Request Information
Species Sea Lion
Assay Time 3.5–5 hours
Detection Method Colorimetric (TMB/HRP)
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size (2) - 48 T, 96 T
  • Lead time: varies by selected option.
  • Storage: 4°C (short-term); -20°C (long-term)
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: store at the recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Options selector
Catalog no. Size
AE16222SE-48T 48 T
AE16222SE-96T 96 T
Field Specification
Product Type
  • Sandwich ELISA Kit
Sensitivity Request Information

Assay Principle

This assay employs a two-site sandwich ELISA to quantitate T3 in samples. An antibody specific for T3 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyT3 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for T3 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of T3 bound in the initial step. The color development is stopped and the intensity of the color is measured.

Performance Specifications

Sensitivity Request Information
Detection Range Request Information
Total Assay Time 3.5–5 hours
Compatible Sample Types serum, plasma, cell culture supernatant, tissue homogenate
Species Reactivity Sea Lion
Detection Method Colorimetric (TMB/HRP)
Storage 4°C (short-term); -20°C (long-term)

✓ Research-Grade Validation

Safety & Regulatory

Research Use Only (RUO). This product is intended for research purposes only and is not approved for diagnostic, therapeutic, or clinical use.

Handle reagents in accordance with institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for complete hazard and handling information. Contains components that may require special disposal procedures per local regulations.

What sample types are compatible with this T3 ELISA kit?

This kit is validated for use with serum, plasma, cell culture supernatant, tissue homogenate. For unlisted matrices (e.g., tissue lysate, urine), perform a spike-and-recovery experiment to confirm assay performance before generating reportable data. Sample dilution in the kit's provided diluent is recommended to minimize matrix interference.

What is the detection limit for T3?

The minimum detectable concentration (sensitivity) of this kit is Request Information. Values below this threshold should be reported as below the limit of detection (<LOD) and should not be extrapolated from the standard curve.

How long does the complete assay take?

The total assay time from sample addition to absorbance reading is approximately 3.5–5 hours, including all incubation, wash, and substrate steps. Hands-on time is typically 1–2 hours; most steps involve passive plate incubation. Plan the assay as a single uninterrupted session for best results.

What reagents and materials are included in the kit?

Standard components of this Sandwich ELISA Kit typically include: pre-coated microplate (96-well strip format), lyophilized or liquid recombinant T3 standard, detection antibody, streptavidin-HRP conjugate, TMB substrate, stop solution, wash buffer concentrate, and sample/standard diluent. Refer to the kit insert or datasheet for the exact component list and storage requirements.

What instrument is required to read the assay?

This kit uses colorimetric (TMB/HRP) detection and requires a standard microplate absorbance reader capable of measuring at 450 nm. A reference wavelength of 570 nm or 630 nm is recommended to reduce background. No specialized fluorescence or luminescence reader is needed. Ensure the instrument is calibrated and the plate is clean and free of condensation before reading.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Supplier Ads Slides show

Add dynamic ads with slider