Overview
UGT1A1 Antibody / Glucuronosyltransferase 1A1 is a research-use antibody directed against UGT1A1. It is supplied for use in common immunoassay contexts such as WB, IHC-P, ELISA (RUO).
Key elements and design rationale
- Target: UGT1A1.
- Description (provided): UDP-glucuronosyltransferase 1-1 also known as UGT-1A is an enzyme that in humans is encoded by the UGT1A1 gene.
- Antibody type: Rabbit, Polyclonal (rabbit origin), Rabbit IgG.
- Format: Antigen affinity purified; Antigen affinity purified.
- Reported/predicted localization: Cytoplasmic.
- Species reactivity: tested: Human, Mouse, Rat.
- Immunogen (if provided): A recombinant human partial protein corresponding to amino acids E316-H533 was used as the immunogen for the UGT1A1 antibody..
The information above helps you match the antibody format to your assay context, interpret species-dependent differences, and anticipate how epitope context (isoforms, PTMs, or conformational state) may influence signal.
Biological background
UDP-glucuronosyltransferase 1-1 also known as UGT-1A is an enzyme that in humans is encoded by the UGT1A1 gene. This gene encodes a UDP-glucuronosyltransferase, an enzyme of the glucuronidation pathway that transforms small lipophilic molecules, such as steroids, bilirubin, hormones, and drugs, into water-soluble, excretable metabolites. This gene is part of a complex locus that encodes several UDP-glucuronosyltransferases. The locus includes thirteen unique alternate first exons followed by four common exons. Four of the alternate first exons are considered pseudogenes. Each of the remaining nine 5' exons may be spliced to the four common exons, resulting in nine proteins with different N-termini and identical C-termini. Each first exon encodes the substrate binding site, and is regulated by its own promoter. The preferred substrate of this enzyme is bilirubin, although it also has moderate activity with simple phenols, flavones, and C18 steroids. Mutations in this gene result in Crigler-Najjar syndromes types I and II and in Gilbert syndrome.
For curated annotations (gene/protein naming, domains, isoforms, and pathway links) for UGT1A1, consult primary databases such as UniProt, NCBI Gene, and Ensembl.
Research relevance and current trends
- Context-dependent expression studies: researchers often examine UGT1A1 abundance and localization across perturbations (genetic, pharmacologic, or environmental) to connect phenotype to molecular changes.
- Reagent reproducibility: there is growing emphasis on antibody specificity checks using orthogonal approaches (e.g., genetic perturbation or independent antibodies) and transparent reporting of clone/lot information.
- Multi-modal datasets: antibody-based readouts are increasingly combined with transcriptomics and imaging to relate protein-level measurements to cell-state transitions.
Common research applications
- Western blotting (immunoblot) for relative detection of target protein abundance and apparent molecular weight.
- Immunohistochemistry for spatial mapping of target expression across tissues and cell types.
- ELISA-based detection or quantification in research assays (format- and epitope-dependent).
When comparing conditions, interpret changes in signal in the context of sample composition, expected localization, and any known isoform complexity for the target.
Notes for experimental interpretation
- Isoforms and PTMs: alternative splicing or post-translational modifications can change epitope accessibility and apparent molecular weight; interpret bands/signals accordingly.
- Cross-reactivity and matrix effects: background binding can vary by sample type, species, and blocking/detection chemistries; include appropriate negative controls.
- Control concepts: where feasible, use genetic perturbation (KO/KD/overexpression), orthogonal assays, or independent antibodies to support specificity claims.
Antibody considerations: Polyclonal reagents may recognize multiple epitopes and can increase sensitivity but may show broader binding profiles, while monoclonal clones provide a single-epitope readout that can improve consistency across experiments. If a conjugate is listed, the antibody supports more direct detection workflows; otherwise, it is typically used with a compatible secondary antibody.
Customization & Add-ons: Can’t find the antibody you need—or require a custom format for your assay? We can help you source the best match or support custom antibody solutions for diverse research needs, including species and isotype selection, conjugations and labeling (e.g., HRP/AP, biotin, fluorophores), purification grade options (Protein A/G, affinity purified), formulation preferences (buffer selection, carrier-free, glycerol-free), custom concentrations and aliquoting, low-endotoxin options for cell-based work, and application-focused QC/validation support (project dependent). Click Talk to a Scientist to submit a request, email us at support@biohippo.com, or explore our Research Services for additional support—our team will follow up with feasibility details and next steps.