Anti-Romiplostim (Nplate) ELISA Kit

SKU:BHE21400132
Overview
Click light‑blue chips for details
Sandwich ELISA kit for quantitative measurement of anti-romiplostim (Nplate) antibodies in serum, plasma and other biological fluid samples. Pre-coated 96-well plate with colorimetric readout at 450 nm; detection range 31.25 - 2,000 ng/mL, sensitivity 17.08 ng/mL. For research use only.
Assay Type Sandwich (Quantitative)
Sample Type Serum, Plasma, Other Fluids
Detection Range 31.25 - 2,000 ng/mL
Sensitivity 17.08 ng/mL
Options selector
Catalog no. Size
AB762018-96T 96 T
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 96 T
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: When the kit was stored at the recommended temperature for 6 months, the signal intensity decreased by less than 20%. For unopened kits, if you want to prolong the storage time, please store the Standard, Detection A, Detection B and Microplate at -20 °C, the rest reagents should be stored at 4 °C.
  • Shipping: 2-8 °C
  • Upon receipt: store the components as listed on the datasheet.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Target Romiplostim
Reactivity
  • Human
Applications
  • ELISA
Assay type
  • Sandwich (Quantitative)
Sample type(s) Serum | Plasma | Other Biological Fluid Samples
Sensitivity 17.08 ng/mL
Detection range 31.25 - 2,000 ng/mL
Detection method
  • Colorimetric
Storage When the kit was stored at the recommended temperature for 6 months, the signal intensity decreased by less than 20%. For unopened kits, if you want to prolong the storage time, please store the Standard, Detection A, Detection B and Microplate at -20 °C, the rest reagents should be stored at 4 °C.
Shipping 2-8 ℃
Catalog no. (Mfr.) AB762018
Main SKU BHE21400132

Product Overview

The Anti-Romiplostim (Nplate) ELISA Kit is a sandwich ELISA kit for quantitative measurement of anti-romiplostim (Nplate) antibodies in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.

In this sandwich format, anti-romiplostim (Nplate) antibodies in the sample bind in the pre-coated wells and are then detected with an enzyme-labeled reagent, so the optical density rises with the antibody level. Results are calculated from the standard curve run on the same plate.

Values are expressed relative to the antibody standard supplied with the kit.

Specifications

Assay Type Sandwich (Quantitative)
Detection Method Colorimetric (OD 450 nm)
Sample Type Serum, Plasma, Other Biological Fluid Samples
Sensitivity 17.08 ng/mL
Detection Range 31.25 - 2,000 ng/mL
Recovery 80-120%
Precision Intra-assay CV <10%; Inter-assay CV <15%
Kit Size 96 T
Shipping 2-8 °C

Sample Preparation

  • Serum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.
  • Plasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.
  • Assay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.
  • Serum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.

Storage & Handling

Ships at 2-8 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.

For Research Use Only. Not for use in diagnostic procedures.

Q.Which sample types can be tested?
A.The kit is intended for serum, plasma and other biological fluid samples. Serum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve. Validate dilution and recovery before running a new matrix.
Q.What are the detection range and sensitivity?
A.The detection range is 31.25 - 2,000 ng/mL and the sensitivity is 17.08 ng/mL. Dilute samples so readings fall within the standard curve.
Q.Can the plate be used partially?
A.Yes. Unused strips can be removed from the frame, returned to the foil pouch with the desiccant and resealed for later use.
Q.How should the kit be stored?
A.Ships at 2-8 °C. Bring reagents to room temperature before use.
Q.Is this kit for diagnostic use?
A.No. This product is for research use only and is not intended for diagnostic or therapeutic procedures.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today