Anti-CD15 antibody from Mouse Monoclonal, clone FUT4/815 isotype IgM, k conjugated to FITC reactive with Human for FC applications. Commonly used in immunology & inflammation studies, including workflows such as flow cytometry.
Target CD15
Clone number FUT4/815
Host Mouse
Reactivity Human
Isotype IgM, k
Conjugate(s) FITC
Application(s) FC
Excitation Laser Blue (488nm)
Options selector
Catalog no. Size
4050012 50 Tests
4050015 100 Tests
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size (2) - 50 Tests, 100 Tests
  • Lead time: typically ships in ~2-3 business days; timing may vary by selected option.
  • Storage: 2-8°C
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: refrigerate upon receipt.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No 4050012; 4050015
Clonality
  • Monoclonal
Conjugate
  • FITC
Host Mouse
Isotype
  • IgM
  • k
Product Type
  • Antibodies
  • Primary Antibodies
  • Flow Cytometry Antibodies
Reactivity
  • Human
Storage 2-8°C
Target CD15

Overview

CD15 FITC is a Mouse monoclonal targeting CD15, supplied as a FITC format for FC workflows. It supports measurement of Human target expression in common experimental systems.

Key elements and design rationale

  • Clone: FUT4/815 — consistent clone identity can support panel reproducibility and cross-study comparisons.
  • Isotype: IgM, k — informs selection of matched controls and secondary reagents when relevant.
  • Conjugate: FITC — enables direct detection in fluorescence-based assays. Excitation is typically matched to Blue (488nm) lasers in cytometer configurations.
  • Host species: Mouse — useful for panel design and control strategy planning.
  • Reactivity: Human — interpret staining in the context of species-specific sequence and expression differences.

Key specifications such as clone identity, isotype, and fluorophore conjugation help researchers align panel design, control selection, and instrument configuration with the biological question and sample type.

Biological background

The clone FUT4/815 recognizes CD15, a cell surface protein (~220kDa) abundantly expressed by granulocytes and monocytes. CD15 plays important role in mediating phagocytosis, bactericidal activity, and also chemotaxis. CD15 is also expressed by Reed-Sternberg cells and some other epithelial cells. CD15 is very useful in the identification of Hodgkin s disease and also large cell lymphomas of both B and T phenotypes.

Research relevance and current trends

  • High-parameter immunophenotyping: combining CD15 with complementary lineage and activation markers to resolve complex cell states.
  • Panel standardization and data comparability: increasing emphasis on consistent reagents, compensation-aware fluorophore choices, and shared gating strategies.
  • Integration with single-cell multi-omics: pairing surface marker profiling with transcriptomic or proteomic readouts to connect phenotype to function.

Common research applications

  • Flow cytometry: quantify CD15-positive populations and compare expression distributions across conditions or time points.
  • Cell sorting: enrich CD15-defined subsets for downstream RNA/protein assays or functional readouts.

Changes in measured signal are typically interpreted in the context of cell subset frequency, activation/differentiation state, and sample processing effects rather than as a standalone readout.

Notes for experimental interpretation

  • Fluorophore selection: consider brightness, spectral overlap, and instrument configuration; compensation and spillover can affect apparent population boundaries.
  • Biology-driven confounders: activation state, differentiation, and isoform/PTM variation can shift epitope accessibility and apparent expression.
  • Control concepts: include matched isotype and fluorescence-minus-one (FMO) controls where appropriate, and interpret results alongside biological positive/negative reference samples.

For antibody-based assays, monoclonal versus polyclonal format can influence epitope recognition breadth and signal consistency. Conjugated antibodies support direct detection and can simplify multicolor panel design when paired with appropriate controls and instrument settings.

Customization & Add-ons: Can’t find the antibody you need—or require a custom format for your assay? We can help you source the best match or support custom antibody solutions for diverse research needs, including species and isotype selection, conjugations and labeling (e.g., HRP/AP, biotin, fluorophores), purification grade options (Protein A/G, affinity purified), formulation preferences (buffer selection, carrier-free, glycerol-free), custom concentrations and aliquoting, low-endotoxin options for cell-based work, and application-focused QC/validation support (project dependent). Click Talk to a Scientist to submit a request, email us at support@biohippo.com, or explore our Research Services for additional support—our team will follow up with feasibility details and next steps.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today