CD38 PE-Cyanine5

SKU:BHA19901103
Suppliers
Caprico
Caprico
Details Products
Overview
Click light‑blue chips for details
Anti-CD38 antibody from Mouse Monoclonal, clone OKT10 isotype IgG1, k conjugated to PE-Cyanine5 reactive with Baboon, Cynomolgus monkey, Human, Rhesus for FC applications. Commonly used in immunology & inflammation studies, including workflows such as flow cytometry.
Target CD38
Clone number OKT10
Host Mouse
Reactivity Baboon, Cynomolgus monkey, Human, Rhesus
Isotype IgG1, k
Conjugate(s) PE-Cyanine5
Application(s) FC
Excitation Laser Blue (488nm)
Options selector
Catalog no. Size
4008072 50 Tests
4008075 100 Tests
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size (2) - 50 Tests, 100 Tests
  • Lead time: typically ships in ~2-3 business days; timing may vary by selected option.
  • Storage: 2-8°C
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: refrigerate upon receipt.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No 4008072; 4008075
Clonality
  • Monoclonal
Conjugate
  • PE-Cyanine5
Host Mouse
Immunogen Human acute lymphoblastic leukaemia cells
Isotype
  • IgG1
  • k
Product Type
  • Antibodies
  • Primary Antibodies
  • Flow Cytometry Antibodies
Reactivity
  • Baboon
  • Cynomolgus monkey
  • Human
  • Rhesus
Storage 2-8°C
Target CD38

Overview

CD38 PE-Cyanine5 is a Mouse monoclonal targeting CD38, supplied as a PE-Cyanine5 format for FC workflows. It supports measurement of Baboon, Cynomolgus monkey, Human, Rhesus target expression in common experimental systems.

Key elements and design rationale

  • Clone: OKT10 — consistent clone identity can support panel reproducibility and cross-study comparisons.
  • Isotype: IgG1, k — informs selection of matched controls and secondary reagents when relevant.
  • Conjugate: PE-Cyanine5 — enables direct detection in fluorescence-based assays. Excitation is typically matched to Blue (488nm) lasers in cytometer configurations.
  • Host species: Mouse — useful for panel design and control strategy planning.
  • Reactivity: Baboon, Cynomolgus monkey, Human, Rhesus — interpret staining in the context of species-specific sequence and expression differences.

Key specifications such as clone identity, isotype, and fluorophore conjugation help researchers align panel design, control selection, and instrument configuration with the biological question and sample type.

Biological background

The clone OKT10, a mouse monoclonal antibody, recognizes a 45 kDa, type II transmembrane cell surface glycoprotein known as CD38. The CD38 antigen is expressed on pre-B lymphocytes, plasma cells, thymocytes and monocytes. CD38 also presents on activated T lymphocytes, natural killer (NK) lymphocytes, myeloblasts, and erythroblasts. Antigen expression is detected during the early stage of T- and B-lymphocyte differentiation, then lost during the intermediate stage of maturation, only to reappear during the final stage of maturation. The CD38 antigen is expressed on 90% of CD34+ cells and is not expressed on pluripotent stem cells. CD38 is expressed in T- and B-acute lymphoblastic leukemia (ALL), Burkitt's lymphoma, multiple myeloma, acute myeloid leukemia (AML), and chronic lymphocytic leukemia (CLL).

Research relevance and current trends

  • High-parameter immunophenotyping: combining CD38 with complementary lineage and activation markers to resolve complex cell states.
  • Panel standardization and data comparability: increasing emphasis on consistent reagents, compensation-aware fluorophore choices, and shared gating strategies.
  • Integration with single-cell multi-omics: pairing surface marker profiling with transcriptomic or proteomic readouts to connect phenotype to function.

Common research applications

  • Flow cytometry: quantify CD38-positive populations and compare expression distributions across conditions or time points.
  • Cell sorting: enrich CD38-defined subsets for downstream RNA/protein assays or functional readouts.

Changes in measured signal are typically interpreted in the context of cell subset frequency, activation/differentiation state, and sample processing effects rather than as a standalone readout.

Notes for experimental interpretation

  • Fluorophore selection: consider brightness, spectral overlap, and instrument configuration; compensation and spillover can affect apparent population boundaries.
  • Biology-driven confounders: activation state, differentiation, and isoform/PTM variation can shift epitope accessibility and apparent expression.
  • Control concepts: include matched isotype and fluorescence-minus-one (FMO) controls where appropriate, and interpret results alongside biological positive/negative reference samples.

For antibody-based assays, monoclonal versus polyclonal format can influence epitope recognition breadth and signal consistency. Conjugated antibodies support direct detection and can simplify multicolor panel design when paired with appropriate controls and instrument settings.

Customization & Add-ons: Can’t find the antibody you need—or require a custom format for your assay? We can help you source the best match or support custom antibody solutions for diverse research needs, including species and isotype selection, conjugations and labeling (e.g., HRP/AP, biotin, fluorophores), purification grade options (Protein A/G, affinity purified), formulation preferences (buffer selection, carrier-free, glycerol-free), custom concentrations and aliquoting, low-endotoxin options for cell-based work, and application-focused QC/validation support (project dependent). Click Talk to a Scientist to submit a request, email us at support@biohippo.com, or explore our Research Services for additional support—our team will follow up with feasibility details and next steps.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today