COR (Cortisol) ELISA Kit

SKU:BHE10802440
Overview
Click light‑blue chips for details
Quantitative competitive ELISA kit for measuring universal COR (Cortisol) in Serum, Plasma, Cell Culture Supernatant, and cell or tissue lysate. Includes sensitivity 0.234ng/mL, detection range 0.391–25ng/mL for signal transduction research. Includes assay time 2 hours.
Target Cortisol
Species Universal
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Assay Type Competitive ELISA, Coated with Antigen
Sensitivity 0.234ng/ml
Detection Range 0.391-25ng/ml
Assay Time 2 hours
Options selector
Catalog no. Size
EU0391-96T 96 T
Available Options

Select the variant options shown for this product and review lead time and shipping expectations before ordering.

  • Size: 96 tests (96T) kit.
  • Lead time: options listed as “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: 2-8 °C for 12 months; ships cold (typically with ice packs) is expected.
  • Please ensure someone is available to receive and store the shipment promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No EU0391
Alternative Names Cortisol|COR
Assay Time
  • 2 hours
Detection Method
  • Competitive ELISA
  • Coated with Antigen
Detection Range 0.391-25ng/ml
Product Type
  • ELISA Kits
Reactivity
  • Universal
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Sensitivity 0.234ng/ml
Species Universal
Storage 2-8 °C for 12 months
Target Cortisol

Background

universal COR (Cortisol) is a molecular target commonly studied in signal transduction and metabolism research. Hormones and endocrine mediators support long-range communication between organs and help maintain physiological homeostasis.

Biological role and mechanism

The biological role of COR is typically understood in terms of its molecular category and interaction network. Depending on the model system, it may participate in cell–cell communication, intracellular signaling, enzymatic processing, or regulation of gene expression programs. Mechanistic interpretation is often strengthened by considering upstream regulators and downstream readouts rather than relying on a single marker.

Expression and abundance of COR can vary by tissue, cell type, and physiological state. In many systems, levels are influenced by factors such as developmental stage, immune activation, metabolic status, and cellular stress. Because sample matrix and pre-analytical handling can affect measured concentrations, interpretation is typically strongest when experiments keep collection and processing consistent across groups.

Nomenclature and related terms

COR (Cortisol) may also be referenced as Cortisol and COR in the literature or in databases. When comparing results across studies, confirm that the reported analyte refers to the same molecule, species context, and molecular form (e.g., precursor vs mature protein, or soluble vs membrane-associated forms).

Why it matters in research

  • Understanding how COR relates to energy homeostasis, glucose and lipid metabolism, insulin sensitivity and endocrine regulation, and adipose–liver crosstalk in signal transduction and metabolism research.
  • Interpreting shifts in COR levels alongside other pathway components or complementary markers.
  • Connecting molecular changes to phenotypes such as inflammation, remodeling, metabolism shifts, or cell-state transitions (context-dependent).

Molecular forms and interpretation

For some targets, isoforms, proteolytic processing, or post-translational modifications (such as phosphorylation or glycosylation) can influence function and apparent abundance. If multiple molecular forms are expected in your model, align interpretation with the form most relevant to the biological question.

Disease and translational relevance

COR has been investigated across diverse physiological and disease contexts, and changes in its abundance have been reported in areas aligned with signal transduction and metabolism studies. These associations are interpreted as research findings rather than diagnostic or therapeutic claims, and they should be evaluated alongside model-specific covariates and study design.

?What?s the plate size in FineTest? ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
?How about the shelf life and stability of FineTest? ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest? ELISA Kits have been subject to strict quality test.
?Which cloned antibodies for FineTest? ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
?Can I mix reagents from different batches of FineTest? ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
?Can FineTest? ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
?How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
?Can standard curve be extended to any direction?
FineTest? can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
?Why does detection for serum/plasma sample by FineTest? ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
?What?s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest? can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
?What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Highly different effects of phage therapy and antibiotic therapy on immunological responses of chickens infected with Salmonella enterica serovar Typhimurium

IF: 8.786 Journal: Frontiers in Immunology Cited Date: 2022-10-13

Roe deer stress response to a wind farms: Methodological and practical implications

IF: 4.49 Journal: Ecological Indicators Cited Date: 2020-06-30

Proteomics analysis for key molecules in adrenal glands of Wenchang chickens for their resistance to heat stress

IF: 3.8 Journal: Poultry Science Author: Key Laboratory of Tropical Animal Breeding and Epidemic Disease Research of Hainan Province, School of Tropical Agriculture and Forestry, Hainan University, Haikou 570100, China Cited Date: 2024-08-09

Long-term, medium-term and acute stress response of urban populations of Eurasian red squirrels affected by different levels of human disturbance

IF: 2.74 Journal: PLOS ONE Author: Department of Forest Zoology and Wildlife Management, Warsaw University of Life Sciences, Warsaw, Poland. Cited Date: 2024-05-06

Stress hormone level and the welfare of captive European bison (Bison bonasus): the effects of visitor pressure and the social structure of herds

IF: 1.683 Journal: Acta Veterinaria Scandinavica Cited Date: 2021-06-17

Impact of thermal stress exposure on seminal quality, antioxidant defence system, TNF-α and TIMP-3 in Ossimi ram

IF: 1.641 Journal: Reproduction in Domestic Animals Cited Date: 2021-01-26

Adaptability of Barbados Blackbelly rams towards elevated temperature-humidity index assessed through reproductive physiology and behaviour

IF: 1.4 Journal: Small Ruminant Research Author: Institute of Biological Sciences, Faculty of Science, Universiti Malaya, 50603 Kuala Lumpur, Malaysia Cited Date: 2025-11-07

Effect of Sargassum Hystrix Extracts on Weight and Blood Biochemical Profile of Wistar Rats Under Condition of Swimming Stress and Fasting

IF: Journal: Proceeding of the 2nd International Conference on Tropical Agriculture Cited Date: 2018-12-05

Faecal glucocorticoid analysis as indicator of stress and its effect on the reproduction hormones of the female Malayan sun bear (Helarctus malayanus) in captivity

IF: Journal: IOP Conference Series: Earth and Environmental Science Author: Faculty of Applied Sciences, Universiti Teknologi MARA Sabah Branch, Kota Kinabalu campus, 88997, Kota Kinabalu, Sabah, Malaysia Cited Date: 2024-03-29

Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today