EnzyChrom Fumarase Assay Kit is designed for quantitative determination of fumarase enzyme activity. It uses OD565 nm readout; suited to plasma, serum, erythrocytes; typical assay time 40 min; detection limit 0.4 U/L.
Detection method Colorimetric (OD 565 nm)
Sample type Biological samples (e.g. plasma, serum, erythrocytes, tissue
Species All species
Procedure 40 min
Detection limit 0.4 U/L
Options selector
Catalog no. Size
EFMR-100 100 Tests
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 100 Tests
  • Lead time: varies by selected option; please contact us for current fulfillment timing.
  • Storage: -20°C — Store at -20°C (freezer). Avoid repeated freeze-thaw cycles.
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: store at the recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No EFMR-100
Assay Time
  • 40 min
Detection Method
  • Colorimetric (OD 565 nm)
Product Type
  • Assay Kits
  • Carbohydrate & Energy Metabolism
Sample Type(s) Biological samples (e.g. plasma, serum, erythrocytes, tissue, and culture media)
Shipping Cold pack (ICE) — Ships on ice (cold pack included). Store immediately upon receipt.
Species All
Storage -20°C — Store at -20°C (freezer). Avoid repeated freeze-thaw cycles.

Overview

For quantitative determination of fumarase enzyme activity. The assay uses OD565nm for signal readout. Compatible sample input includes Biological samples (e.g. plasma, serum, erythrocytes, tissue, and culture media). Typical stated assay timing is 40 min.

Key elements and design rationale

  • Readout format: OD565nm supports plate-based signal acquisition and consistent comparison across matched samples.
  • Sample compatibility: The stated sample scope includes Biological samples (e.g. plasma, serum, erythrocytes, tissue, and culture media), which is useful when aligning matrix type with calibration and control design.
  • Analytical range context: The supplied specifications include a stated detection limit of 0.4 U/L for interpreting low-signal samples.
  • Feature emphasis: Fast and sensitive. Linear detection range: 0.4 to 70 U/L for 30 min reaction at 37°C.

Additional feature notes highlight Convenient and high-throughput. Homogeneous “mix-incubate-measure” type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Available format information for this listing includes 100 Tests.

Biological background

This product is centered on measurement of fumarase within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.

More details

FUMARASE (or fumarate hydratase) (EC 4.2.1.2) is an enzyme that catalyzes the reversible hydration/dehydration reaction of fumarate to malate. Fumarase exists in two isoforms: a cytosolic and mitochondrial form. In the citric acid cycle, it facilitates a transition step in the production of energy in the form of NADH. Fumarase deficiency in humans results in early brain development problems and is characterized by poor feeding, hypotonia, failure to thrive, etc. BioAssay Systems’ non-radioactive, colorimetric fumarase assay is based on the reduction of the tetrazolium salt MTT in an NADH-coupled enzymatic reaction to a reduced form of MTT which exhibits an absorption maximum at 565 nm. The increase in absorbance at 565 nm is proportional to the enzyme activity.

Detection method

Colorimetric (OD 565 nm).

Detection limit and analytical sensitivity

Reported detection limit: 0.4 U/L.

Procedures and timing

Stated procedure or timing information: 40 min.

Research relevance and current trends

  • Plate-based quantification and side-by-side group comparison remain central use cases for this assay format.
  • The product notes emphasize multi-sample throughput, making it relevant for screening-oriented and larger batch comparison studies.
  • Short assay timing and plate compatibility support time-course or repeated-measure collection plans when handling is kept consistent.

Common research applications

  • Quantify fumarase in plasma, serum, erythrocytes by OD565 nm readout.
  • Compare treatment or phenotype groups using matched plasma, serum, erythrocytes handling.
  • Monitor time-course or pre/post changes in plasma, serum, erythrocytes across study conditions.

Interpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.

Notes for experimental interpretation

  • Matrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.
  • Use appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.

For laboratories requiring additional technical capacity, we provide scientific support services including assay execution, method guidance, product sourcing, and customization to align the assay with specific experimental objectives. If you need assistance selecting the appropriate kit configuration, adapting the workflow to your application, or identifying related research services, please click Talk to a Scientist, email support@biohippo.com, or review our Research Services; a member of our scientific team will follow up with recommendations tailored to your study.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today