General Nicotinic Acid Adenine Dinucleotide Phosphate (NAADP) ELISA Kit

SKU:BHE13504144
Overview
Click light‑blue chips for details
Quantitative competitive ELISA kit for measuring NAADP in serum and plasma (range 0.156-10ng/mL) with 0.055ng/mL sensitivity Includes all reagents for standard-curve quantification..
Assay Type Competitive ELISA
Detection Method Colorimetric (OD450)
Detection Range 0.156-10ng/mL
Sensitivity 0.055ng/mL
Species General
Assay Validation QC Passed
Options selector
Catalog no. Format Size
DL-NAADP-Ge-48T Traditional
DLR-NAADP-Ge-48T Ready-to-use
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Format (2) - Traditional | Ready-to-use; Size (2) - 48 T | 96 T
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: Store at 2–8 °C short-term; freeze reconstituted standards at −20 °C.
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: store at recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No DL-NAADP-Ge, DLR-NAADP-Ge
Detection Range 0.156-10ng/mL
Product Type
  • Competitive ELISA Kit
Sample Type(s) serum, plasma or other biological fluids.
Sensitivity 0.055ng/mL
Species General

Assay Principle

Nicotinic Acid Adenine Dinucleotide Phosphate (NAADP) is a biomarker protein expressed in mammalian tissues and biological fluids. Dysregulation of NAADP has been implicated in cellular signaling and fundamental cell biology, making it a relevant biomarker for investigational studies.

Quantitative measurement of NAADP enables researchers to characterize its abundance in Serum, Plasma and correlate levels with experimental conditions. Studies investigating NAADP have contributed to the understanding of cell signaling pathways, disease pathogenesis, and therapeutic target validation.

This competitive ELISA kit provides a validated, reproducible format for NAADP quantification within the inhibition range of 0.156-10ng/mL. The assay supports experimental workflows in Cell Biology research.

Kit Components

Each kit contains sufficient reagents for one 96-well plate (approximately 40 samples in duplicate with standard curve):

Pre-coated microplate (96 wells), HRP-conjugated antigen, standard protein, sample diluent, wash buffer, TMB substrate solution, stop solution, and product manual.

Validated Lot

Performance Data

Assay Type Competitive ELISA
Detection Range 0.156-10ng/mL
Sensitivity (LLOD) 0.055ng/mL
Validated Sample Types Serum, Plasma
Detection Method Colorimetric (450 nm / 540–570 nm reference)
Plate Format 96-well microplate
Shelf Life Traditional: 12 months | Ready-to-use: 16 months

Assay Procedure Summary

Add samples and HRP-conjugated antigen simultaneously to pre-coated wells and incubate. Wash, add TMB substrate, and read at 450 nm. Signal is inversely proportional to Nicotinic Acid Adenine Dinucleotide Phosphate concentration. Construct a standard inhibition curve from the provided reference antigen to calculate sample concentrations.

Pre-warm all kit components to room temperature (18–25 °C) for 30 minutes before starting. Run all samples in duplicate. Centrifuge samples at ≥1,000 × g before use to remove particulates.

Safety & Intended Use

Research Use Only. For Research Use Only (RUO). Not for diagnostic, therapeutic, or clinical use. Handle in accordance with good laboratory practice.

Intended UseResearch Use Only (RUO)VendorDLdevelopCatalog No.DL-NAADP-Ge, DLR-NAADP-GeSpeciesSee title

What sample types are compatible with this Nicotinic ELISA kit?

This kit is validated for serum and plasma. Centrifuge samples at ≥1,000 × g for 15 min to remove particulates. Avoid hemolyzed, lipemic, or heat-inactivated samples. As a competitive format, higher analyte concentration produces lower signal — dilute proportionally. Pre-dilute samples within the linear range before committing full plates.

What is the detection limit and range for this Nicotinic assay?

Minimum detectable concentration: 0.055ng/mL. Quantitative standard curve range: 0.156-10ng/mL. Samples above the upper limit must be diluted; near-lower-limit samples require duplicate measurement.

How long does the complete assay protocol take?

A typical sandwich ELISA protocol for this kit requires 3.5–5 hours. Pre-warm reagents to room temperature (18–25 °C) for at least 30 minutes before starting and prepare standard dilutions while the capture plate equilibrates.

What instrument is required to read this assay?

A standard microplate spectrophotometer set to 450 nm (reference: 540–570 nm) is required. An automated plate washer reduces wash-step variability. Calibrate and warm up your reader before measuring. Blank using the zero-standard or buffer-only well before constructing the standard curve.

How should I store this kit, and what is its shelf life?

Store the unopened kit at 2–8 °C until the expiry date. Shelf life: Traditional: 12 months | Ready-to-use: 16 months from date of manufacture. Reconstituted standard is stable at 4 °C for ≤1 week; prepare fresh for critical experiments.

Looking for a custom format, bulk quantity, or specialized formulation? We offer flexible sourcing options. Contact us to discuss your specific requirements.

Matches this product
$50 OFF
$50 Off All ELISA Kits
Limited time ELISA50
15%OFF
15% Off Cancer Antibodies
Ends Sep 30 ONCO15
10% OFF
10% OFF CELL LINES-Limited-Time Offer
Ends Sep 30 CELL10
FREE SAMPLE
Free Sample – CellTrypase Recombinant Trypsin-Like Enzyme
Limited time offer – availa... FREESAMPLE
FREE SAMPLE
Free Sample – MycoFold™ Growth Factors
Limited time offer – availa... Request Free Sample

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today