| Field | Specification |
|---|---|
| Mfr No | |
| Form | liquid |
| Product Type | |
| Shipping | |
| Storage |
Description
Hieff NGSTM DNA Selection Beads are magnetic beads based on the Solid Phase Reversible Immobilization (SPRI) principle, designed for DNA purification and size selection during next-generation sequencing (NGS) library preparation. The beads are compatible with a wide range of DNA and RNA library preparation kits.
Features
- Premium Quality: High-quality raw materials ensure excellent recovery rates and precise size selection.
- High Compatibility: Compatible with all major DNA and RNA library preparation kits.
- Batch Consistency: Strict quality control ensures stable and reliable lot-to-lot performance.
Specifications
|
Product Line |
DNA clean and selection Beads |
|
Starting Material |
DNA |
|
Compatibility |
DNA |
|
Isolation Technology |
Magnetic Bead |
|
Final Product Type |
DNA |
|
For Use With (Application) |
DNA clean up, DNA size slection |
Storage
This product should be stored at 2~8℃ for 18 months.
Figures
1.Workflow
Figure 1. The workflow of DNA size selection.
2.High purification recovery efficiency

Figure 1. The workflow of DNA size selection.
High-ratio DNA purification: Comparable DNA recovery efficiency observed across different brands of magnetic beads. Low-ratio DNA purification: Yeasen magnetic beads demonstrate higher DNA recovery efficiency.
3.Highly consistent size selection precision

Figure 3. Comparison of DNA bead separation performance. Consistent separation precision observed across different separation ratio conditions.
FAQ
Q: Can 12601 be used for DNA purification?
A: It can purify DNA fragments of 150bp or longer. If the purified DNA contains a large amount of fragments shorter than 150bp, please use product number 12600, which can purify DNA fragments of 50bp or longer.
Q: Can 12601 separate DNA fragments of 1Kb or larger?
A: You need to figure out the system on your own. The currently selected system for the selected fragments is the one described in the manual. For other fragment selections, you can refer to the selection system in the manual for adjustment.
Q: I accidentally placed the magnetic beads at -20℃, but they did not freeze. Can I still use them?
A: It is not recommended to freeze for a long time, as the low temperature will damage the structure of the magnetic beads. Freezing and thawing once for NGS library sorting and purification does not significantly affect the performance for a short period of time. However, the actual result should be based on specific test results.
Q: If the magnetic beads are stored at 4℃ before opening, and then used at room temperature after opening, will this affect the recovery performance of the magnetic beads?
A: Keeping the magnetic beads at room temperature may have some impact on their recovery performance. It is not recommended to leave them at room temperature for too long. After use, it is advisable to store them at 4℃. The separation effect of PEG is easily affected by factors such as pH and temperature.
Q: Principle of Magnetic Bead Purification
A: The DNA sorting and purification magnetic beads are based on a technology called Solid Phase Reversible Immobilization (SPRI). The buffer of the magnetic beads generally contains: magnetic beads, DNA, PEG, salt ions (mainly Na+), etc. Under the action of PEG and NaCl, the DNA molecules will undergo dehydration condensation, resulting in a change in DNA conformation and aggregation precipitation. The negatively charged ones can be eluted from the bound DNA molecules when using buffer solutions without enzymes or TE (low salt and low PEG content).
Q: The principle of magnetic bead sorting
A: Under different PEG and salt ion concentrations, the conformations of different lengths of DNA are different. Moreover, longer DNA fragments carry more negative charges, so magnetic beads generally preferentially adsorb long DNA fragments. Sorting usually requires two rounds of magnetic bead separation. In the first round, magnetic beads bind to the DNA of larger molecular weight, and this part of the product is removed by discarding the magnetic beads. At this time, the target-sized DNA is in the supernatant; in the second round, magnetic beads bind to the larger molecular weight DNA in the remaining products, and the smaller molecular weight DNA is removed by discarding the supernatant. At this point, the target-sized DNA is on the magnetic beads, and through two rounds of magnetic bead separation, the sorting goal is achieved.
Q: Can 12601 be used to purify or recover fragments smaller than 150 base pairs?
A: It is not recommended to use 12601. Instead, 12600 should be used. The minimum fragment that can be recovered is about 100bp. The recovery rate of 50bp or above may be affected.
Q: Is it possible to purify single-stranded DNA? How many magnetic beads should be used?
A: Magnetic beads can adsorb both double-stranded DNA and single-stranded DNA, but they cannot distinguish between single-stranded or double-stranded DNA. The number of times single-stranded DNA can be purified by the magnetic beads can be referred to in the manual for double-stranded DNA.
Q: Does it selectively adsorb DNA and thereby remove RNA from the sample?
A: 12601ES is a non-specific adsorption magnetic bead that can also bind to RNA. If you want to remove RNA, you need to treat it with RNase A.
Q: Can it be used for RNA purification and sorting?
It is not recommended to use it. Although magnetic beads can also adsorb RNA fragments, the magnetic bead buffer is designed based on DNA characteristics and is not conducive to the stability of RNA structure. For RNA purification, it is recommended to use RNA purification magnetic beads (item number 12602ES).
Q: What could be the possible reasons for the low recovery rate of magnetic beads?
A: 1) The magnetic beads and DNA were not thoroughly mixed, resulting in insufficient adsorption. It is recommended to ensure thorough mixing of the reaction system.
2) The proportion of magnetic beads is incorrect. It is recommended to select the appropriate proportion according to the instructions.
3) The incubation time is insufficient. Ensure that the incubation time is at least 5 minutes.
4) During magnetic bead separation, when the two wheels perform magnetic bead adsorption, the magnetic beads are collected. A 10 μL pipette can be connected in series before the 200 μL pipette for liquid transfer, which can prevent the collection of magnetic beads.
5) During the magnetic bead washing process, the ethanol solution was not prepared freshly, resulting in an insufficiently high ethanol concentration. It is recommended that the ethanol concentration be no less than 70%, and for small fragments, it should be no less than 80%.
6) Excessive drying: If the magnetic beads are dried for too long, the surface will crack, making it difficult to elute the DNA and resulting in a decrease in yield. It is recommended that the drying time should not be too long; the moment the surface begins to crack, drying should be stopped.
7) Insufficient volume of elution solution: The final elution solution should completely cover the magnetic beads within the tube.
8) Sample reasons: The sample purity is low and contains impurities. When there are a large amount of impurities in the sample, it may cause the magnetic beads to aggregate and harden, resulting in insufficient elution. Using a pipette, try to blow the magnetic beads apart as much as possible, extend the elution time, and increase the product recovery rate. If there are many large fragments in the sample, the large fragments will cause the magnetic beads to aggregate. During elution, you can prolong the time or, if necessary, incubate at 37 degrees to improve the yield.
Documents:
SPRI (Solid Phase Reversible Immobilization) beads bind DNA in the presence of polyethylene glycol (PEG) and salt. At higher bead:sample ratios, smaller DNA fragments bind; at lower ratios, only larger fragments bind. Unbound DNA is removed by washing, then the size-selected DNA is eluted with low-salt buffer or water. Adjusting the bead volume controls the fragment size cutoff.
These beads work with a broad range of DNA inputs from standard NGS library preparation workflows, including adapter-ligated fragments. They are compatible with all major DNA and RNA library prep kits from leading suppliers. Specific input recommendations are in the protocol manual (see Documents).
A 1.8× ratio (1.8 µL beads per 1 µL sample) is commonly used for removing adapter dimers and small fragments (<150 bp). For size selection windows (e.g., 300–600 bp), dual-sided selection using lower and higher ratios is recommended. Specific ratio guidance for each application is provided in the product manual.
Store at 2–8°C for up to 18 months. Do not freeze — freezing disrupts bead dispersion and can reduce size selection performance. Allow beads to equilibrate to room temperature (15–30 min) before use and vortex or swirl gently to resuspend. Do not use if the suspension appears aggregated or discolored.
Yes — Hieff NGS DNA Selection Beads are designed for magnetic separation without centrifugation, making them compatible with standard 96-well deep-well plates, magnetic separation plates, and automation platforms including liquid handlers. High lot-to-lot consistency ensures reproducible performance across automated runs.
The following customization and add-on services may be available for this product type through the supplier. For inquiries and pricing, contact support@biohippo.com.
Customization Options
- Bulk Quantities: Larger volumes and custom pack sizes beyond the standard catalog may be available for high-throughput core facilities and industrial customers. Contact us to inquire about bulk pricing.
- Custom Antibody Coupling (Magnetic Beads): Custom magnetic beads conjugated to your specific antibody or protein ligand may be available through Yeasen's OEM and custom services program. These services leverage the same bead platform used for catalog products.
- OEM Manufacturing: Custom bead formulations for diagnostic device development, including magnetic beads for nucleic acid isolation, IP-grade beads, and affinity capture beads, may be available at manufacturing scale.
To inquire about custom options or bulk pricing, contact support@biohippo.com.