Hifair™ AdvanceFast One-step RT-gDNA Digestion SuperMix for qPCR

SKU:BHT20800056 PCR & qPCR
Overview
Click light‑blue chips for details
Hifair™ AdvanceFast One-step RT-gDNA Digestion SuperMix for qPCR represents an enhanced iteration of the Hifair™ Ⅲ 1st Strand cDNA Synthesis SuperMix for qPCR (gDNA Digester Plus). It is designed to fulfill the demands of conducting both reverse transcription and genome removal reactions within a si
Mix Type One-Step RT-qPCR Mix
Hot Start No
Grade RUO
Storage -80°C
Shipping Dry Ice
Available Options

Select the size format that best suits your experiment. Availability and lead time may vary by option.

  • Options: Size (2) — 10 T, 100 T
  • Lead time: varies by selected option; please contact us for current fulfillment timing.
  • Storage: -80°C
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: store at the recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Options selector
Catalog no. Size
11151ES10 10 T
11151ES60 100 T
Field Specification
Product Type
  • RT Kit
Shipping Dry Ice
Storage -80°C

Hifair™ AdvanceFast One-Step RT-gDNA Digestion SuperMix for qPCR performs reverse transcription and genomic DNA removal in a single tube, streamlining workflow and significantly reducing total reaction time while increasing cDNA yield. The 4× Hifair® AdvanceFast One-Step RT SuperMix contains all essential RT reagents — add gDNA Remover Mix, RNA template, and water to initiate. Suitable for complex RNA templates and effective for low-abundance transcripts.

Features

  • Single-tube simultaneous reverse transcription and gDNA elimination
  • Reduced workflow time vs. two-step approaches
  • Effective for complex RNA templates and low-abundance transcripts
  • Stable for 12 months at −15 to −25°C

Specifications

Parameter Value
End Product cDNA (First-Strand)
PCR Method RT-PCR
Sample Type RNA
Optimal Reaction Temperature 37°C
Reverse Transcriptase M-MLV (engineered)

Kit Components

Component 11151ES10 (10 rxn) 11151ES60 (100 rxn)
4× Hifair® AdvanceFast One-Step RT SuperMix (11151-A) 50 µL 500 µL
gDNA Remover Mix (11151-B) 10 µL 100 µL
RNase-Free Water (11151-C) 1 mL 2 × 1 mL

Reaction Setup

Component Volume (µL)
RNase-Free Water To 20
4× Hifair® AdvanceFast One-Step RT SuperMix 5
gDNA Remover Mix 1
Total RNA 10 pg – 5 µg*
or mRNA 10 pg – 500 ng*

* Do not exceed 2 µg total RNA per reaction.

The one-step format performs gDNA removal and reverse transcription in a single tube without intermediate steps or tube transfers. This significantly reduces total workflow time, minimizes RNA degradation risk during handling, and reduces the potential for cross-contamination between samples.

Total RNA input: 10 pg to 5 µg per reaction (do not exceed 2 µg for standard workflows). mRNA input: 10 pg to 500 ng. For low-expression targets, total RNA can be increased within the stated upper limit.

Shipped on dry ice. Store at −15 to −25°C for up to 12 months.

Yes. The AdvanceFast formulation is specifically designed for complex RNA templates and is validated for effective reverse transcription of low-abundance transcripts.

Both perform genomic DNA removal, but the gDNA Remover Mix in this one-step format is optimized for use in a combined RT + gDNA removal reaction at 37°C without requiring a separate digestion step. The separate 5× gDNA Digester Mix in Cat# 11141 operates in a distinct sequential digestion step before reverse transcription.

Yeasen Biotechnology supports custom formulation and scale-up services for reagent mixes and master mixes. Contact BioHippo to discuss project requirements and initiate an inquiry.

▶ GMP-Grade & Bulk Supply

Select Yeasen reagent mixes are available in GMP grade for IVD assay development. Manufactured in an ISO 13485-certified UCF.ME™ facility with FDA Drug Master File (DMF) support.

  • GMP release testing and CoA documentation
  • Scalable from milliliter to liter-scale quantities
  • Consistent lot-to-lot performance specifications

▶ Glycerol-Free & Lyophilization-Ready Formats

Glycerol-free and lyophilization-ready formats are available for reagents intended for cartridge-based point-of-care devices, liquid handling automation, or ambient-temperature distribution.

  • Glycerol-free liquid formulation
  • Lyophilization-compatible format with cryoprotectant
  • Custom reaction buffer optimization

▶ Molecular IVD RDC Service

Yeasen's Research and Development Contracting team provides end-to-end support for molecular diagnostic product development using Yeasen reagent mixes as a foundation.

  • Master mix selection and performance matching for target assay
  • Primer/probe design and assay buffer optimization
  • Sensitivity, specificity, and LOD validation
  • Instrument compatibility assessment

▶ Custom Formulation

Custom formulation services are available for researchers requiring modifications to standard reagent mix compositions, including ROX level adjustment, dye substitution, stabilizer optimization, and buffer modification.

  • ROX concentration customization (No / Low / High ROX)
  • Reference dye and indicator dye options
  • Buffer composition and pH optimization
  • Scale-up to commercial quantities on confirmation

ⓘ Customization services fulfilled by Yeasen Biotechnology. Contact BioHippo for project scoping and pricing.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Supplier Ads Slides show

Add dynamic ads with slider