Human Adiponectin ELISA Kit PicoKine®

SKU:BHE21000540
Overview
Click light‑blue chips for details
Human Adiponectin (ADIPOQ) PicoKine® Quick ELISA kit is designed for quantitative detection of Adiponectin. Suitable for cell culture supernatants, serum, plasma (heparin, EDTA) and urine. Optimized for a streamlined sandwich ELISA workflow with high signal-to-noise and reproducible results. Reported sensitivity: <60 pg/ml.
Target ADIPOQ
Reactivity Human
Sample Type(s) cell culture supernatants, serum, plasma (heparin, EDTA) and urine.
Assay Type Sandwich ELISA
Sensitivity <60 pg/ml
Detection Range 1.56 ng/ml - 100 ng/ml
Assay Time ~3.5 hours
Options selector
Catalog no. Size
EK0595 96 wells/kit, with removable strips.
Available Options

Select from the available variant options shown for this product. Availability and lead time may vary by option.

  • Options: Size: 96 wells/kit, with removable strips..
  • Lead time: items “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: Store at 4℃ for 6 months, at -20℃ for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.); cold-chain shipment (typically with ice packs) is expected.
  • Please ensure someone is available to receive temperature-sensitive deliveries promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No EK0595
Alternative Names Adiponectin ;Adiponectin, C1Q and collagen domain containing ;cDNA FLJ78108, highly similar to Homo sapiens adiponectin, C1Q and collagen domain containing (ADIPOQ), mRNA ;ADIPOQ ;hCG_1784052 ;
Assay Time
  • ~3.5 hours
Assay Type
  • Sandwich ELISA
Detection Range 1.56 ng/ml - 100 ng/ml
Expression System
  • NS0
Gene ID 9370
Immunogen Expression system for standard: NS0; Immunogen sequence: E19-N244
Product Type
  • ELISA Kits
  • PicoKine® ELISA Kitss
Reactivity
  • Human
Sample Type(s) cell culture supernatants, serum, plasma (heparin, EDTA) and urine.
Sensitivity <60 pg/ml
Storage Store at 4℃ for 6 months, at -20℃ for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Target ADIPOQ
UniProt # A8K660

Background

Also known as: Adiponectin, C1Q and collagen domain containing, cDNA FLJ78108, highly similar to Homo sapiens adiponectin, C1Q and collagen domain containing (ADIPOQ), mRNA, ADIPOQ, hCG_1784052.

Human Adiponectin (ADIPOQ) is a commonly measured biological analyte that can provide insight into cellular state and tissue physiology. This target is frequently investigated in Molecular & Cellular Biology research contexts. Proteases and extracellular matrix (ECM) components are central to tissue architecture and remodeling. In many experimental contexts, changes in ECM-related proteins reflect shifts in cell adhesion, migration, barrier integrity, or matrix turnover.

Biological function and remodeling context

Matrix remodeling is influenced by the balance between synthesis and degradation, often regulated by inflammatory cues, mechanical stress, and growth-factor signaling. Protease activity can unmask or release bioactive fragments, while altered ECM composition can feed back on cell behavior through mechanotransduction and receptor engagement.

Why it matters in research

  • Remodeling readout: Quantification can support studies of fibrosis, wound repair, and invasion models.
  • Microenvironment state: Levels may reflect stromal activation, barrier disruption, or matrix turnover.
  • Mechanistic linkage: Pairing with inflammatory and growth-factor markers can clarify drivers of remodeling.

Disease and translational relevance

ECM remodeling and protease regulation are frequently discussed in the literature across oncology, cardiovascular, pulmonary, and inflammatory disease models. Interpretation of abundance should consider whether the measured analyte represents pro-forms, active forms, or fragments, and whether binding partners in the matrix influence detectability.

Sample data

Concentration (ng/ml)01.563.126.2512.52550100
O.D.0.0560.1050.1480.2470.3820.6441.1031.878

Intra/inter assay consistency

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3726120584992736461147849590
Standard deviation182.57940.522346.56236.991033.022578.68
CV (%)4.9%7.8%4.7%6.5%9%5.2%

Kit components

Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x)|100ul Avidin-Biotin-Peroxidase Complex (100x)|100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB)|10ml Stop Solution|10ml Wash Buffer (25x)|20ml Adhesive plate sealers|4

Materials required but not provided

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.
How many samples can I run per plate?
Each PicoKine® kit (96-well format) typically accommodates a 7-point standard curve in duplicate, 2 non-specific binding wells, and up to 39 unknown samples in duplicate. Exact capacity may vary by kit — refer to the datasheet.
What sample dilution should I use?
Boster recommends performing a pilot study first: run serial dilutions of your samples (e.g. 1:2, 1:4, 1:8, 1:16) to identify the range that falls within the standard curve. This is important because sample matrix and protein expression levels vary significantly by experiment.
Why is my signal weak or absent?
The most common causes are: (1) target protein below the kit's detection limit — try concentrating samples or reducing dilution; (2) reagents not at room temperature before use; (3) insufficient incubation time; (4) expired or contaminated reagents. See Boster's full ELISA troubleshooting guide at bosterbio.com/protocol-and-troubleshooting/picokine-elisa-troubleshooting.
Why is my background signal high?
High background is typically caused by insufficient washing (ensure thorough plate draining after each wash step), excess antibody concentration, or contaminated TMB substrate. Increase the number of wash cycles or reduce antibody concentration. Always use fresh substrate solution.
Are the kit components sterile?
Components are bottled using aseptic techniques and heat-treated vials, but are not guaranteed sterile. If your experiment requires sterile material, filter through a 0.2 µm membrane designed for biological fluids before use.
How do I analyze my ELISA results?
Plot absorbance (OD 450 nm) against standard concentrations and fit a 4-parameter logistic (4PL) or sigmoidal curve. Read unknown sample concentrations from the curve. Boster provides a free online ELISA data analysis tool at bosterbio.com/biology-research-tools/elisa-data-analysis-online.
How should I store samples before running the assay?
Aliquot samples before freezing to avoid repeated freeze-thaw cycles, which can degrade the target protein. Store aliquots at -80°C for long-term use. Serum and plasma should be collected, processed, and stored under consistent conditions to minimise pre-analytical variability.
What positive and negative controls should I include?
Include a positive control (a sample known to contain the target protein at a measurable level) and a negative control (sample matrix without the target, or a sample from a species the kit does not cross-react with). Running controls in every assay validates the assay performance and flags plate-to-plate variability.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

  1. Aleksandra et al. (2024). Biochemical markers and carotid intima-media thickness in relation to cardiovascular risk in young women. Scientific Reports.
  2. Huanyu et al. (2024). Increased serum carboxylesterase-1 levels are associated with metabolic dysfunction associated steatotic liver disease a…. Italian Journal of Pediatrics.
  3. Picchio et al. (2024). Exposure to serum from exclusive heated tobacco product smokers induces mTOR activation and fibrotic features in human c…. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR BASIS OF DISEASE.
  4. Yang et al. (2023). Associations of Three-Dimensional Anthropometric Body Surface Scanning Measurements and Coronary Artery Disease. Medicina-Lithuania.
  5. Islam et al. (2022). Altered serum adiponectin and interleukin-8 levels are associated in the pathophysiology of major depressive disorder: A…. PLoS One.
  6. Fang et al. (2022). Serum Cystatin C Levels Could Predict Rapid Kidney Function Decline in A Community-Based Population. Biomedicines.
  7. Erbaş et al. (2022). Low Complement C1q/TNF-related Protein-13 Levels are Associated with Childhood Obesity But not Binge Eating Disorder. Journal of Clinical Research in Pediatric Endocrinology.
  8. Chu et al. (2022). Relationships Between Metabolic Body Composition Status and Rapid Kidney Function Decline in a Community-Based Populatio…. Frontiers in Public Health.
  9. Silveira et al. (2022). Positive Effects of Extra-Virgin Olive Oil Supplementation and DietBra on Inflammation and Glycemic Profiles in Adults W…. Frontiers in Endocrinology.
  10. Yang et al. (2021). Artificial Intelligence-Assisted Identification of Genetic Factors Predisposing High-Risk Individuals to Asymptomatic He…. Cells.
  11. Mohamed et al. (2020). The Association of Pre-diagnostic Inflammatory Markers and Adipokines and the Risk of Non-Hodgkin Lymphoma Development i…. Indian Journal of Hematology and Blood Transfusion.
  12. Goldsmith et al. (2020). Protein and gene markers of metabolic dysfunction and inflammation together associate with functional connectivity in re…. BRAIN BEHAVIOR AND IMMUNITY.
  13. Ilhan et al. (2019). The emerging role of leptin, Adiponectin and Visfatin in Ischemic/Hemorrhagic stroke. BRITISH JOURNAL OF NEUROSURGERY.
  14. Li Juan, Shen Xingping (2019). Oxidative stress and adipokine levels were significantly correlated in diabetic patients with hyperglycemic crises. Diabetology & Metabolic Syndrome.
  15. Yang et al. (2019). Adiponectin protects against uric acid‑induced renal tubular epithelial inflammatory responses via the AdipoR1/AMPK sign…. INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE.
  16. Bekhbat et al. (2018). Glucose and lipid-related biomarkers and the antidepressant response to infliximab in patients with treatment-resistant …. PSYCHONEUROENDOCRINOLOGY.
  17. Liu et al. (2018). Protective effects of sarsasapogenin against early stage of diabetic nephropathy in rats. PHYTOTHERAPY RESEARCH.
  18. Azzini et al. (2017). Effect of Red Orange Juice Consumption on Body Composition and Nutritional Status in Overweight/Obese Female: A Pilot St…. Oxidative Medicine and Cellular Longevity.
  19. CHEN et al. (2017). CDH13 Genetic Polymorphisms, Adiponectin and Ischemic Stroke: a Chinese Family-based Sib-pair Study. BIOMEDICAL AND ENVIRONMENTAL SCIENCES.
  20. Küme et al. (2017). The Relationship between Serum Zonulin Level and Clinical and Laboratory Parameters of Childhood Obesity. Journal of Clinical Research in Pediatric Endocrinology.
  21. Çatlı et al. (2016). Relation of serum irisin level with metabolic and antropometric parameters in obese children. JOURNAL OF DIABETES AND ITS COMPLICATIONS.
  22. Buturak et al. (2016). Elective percutaneous coronary intervention leads to significant changes in serum resistin, leptin, and adiponectin leve…. Anatolian Journal of Cardiology.
  23. Mohammad-Shahi et al. (2015). Soy milk consumption, markers of inflammation and oxidative stress in women with rheumatoid arthritis: A randomised cros…. Nutrition & Dietetics.
  24. Jafari-Vayghan et al. (2015). Association Between Dietary Patterns and Serum Leptin-to-Adiponectin Ratio in Apparently Healthy Adults. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION.
  25. Serap et al. (2015). The Effect of Isotretinoin on Retinol-Binding Protein 4, Leptin, Adiponectin and Insulin Resistance in Acne Vulgaris Pat…. DERMATOLOGY.
  26. Saraf-Bank et al. (2014). Effect of non-soy legume consumption on inflammation and serum adiponectin levels among first-degree relatives of patien…. NUTRITION.
  27. Enli et al. (2014). Adipocytokine concentrations in children with different types of beta-thalassemia. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION.
  28. Serap et al. (2013). The Effect of Acitretin Treatment on Insulin Resistance, Retinol-Binding Protein-4, Leptin, and Adiponectin in Psoriasis…. DERMATOLOGY.
  29. BC et al. (2013). Maternal adiponectin and visfatin concentrations in normal and complicated pregnancies.. Clinical and Experimental Obstetrics & Gynecology.
  30. Liu et al. (2011). High salt intake fails to enhance plasma adiponectin in normotensive salt-sensitive subjects. NUTRITION.
Matches this product
$50 OFF
$50 Off All ELISA Kits
Limited time ELISA50
15%OFF
15% Off Cancer Antibodies
Ends Sep 30 ONCO15
10% OFF
10% OFF CELL LINES-Limited-Time Offer
Ends Sep 30 CELL10
FREE SAMPLE
Free Sample – CellTrypase Recombinant Trypsin-Like Enzyme
Limited time offer – availa... FREESAMPLE
FREE SAMPLE
Free Sample – MycoFold™ Growth Factors
Limited time offer – availa... Request Free Sample

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today