Human Anti-Hepatitis D Virus/HDV IgG ELISA Kit

SKU:BHE21400596
Overview
Click light‑blue chips for details
ELISA kit for quantitative measurement of human IgG antibodies against Hepatitis D Virus/HDV in serum and plasma. Pre-coated 96-well plate with colorimetric readout at 450 nm; detection range 1.56 - 100 ng/mL, sensitivity 0.25 ng/mL. For research use only.
Assay Type Quantitative
Sample Type Serum, Plasma
Detection Range 1.56 - 100 ng/mL
Sensitivity 0.25 ng/mL
Options selector
Catalog no. Size
VK175018-96T 96 T
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 96 T
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
  • Shipping: 2-8 °C
  • Upon receipt: store the components as listed on the datasheet.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Applications
  • ELISA
Assay type
  • Quantitative
Sample type(s) Serum | Plasma
Sensitivity 0.25 ng/mL
Detection range 1.56 - 100 ng/mL
Detection method
  • Colorimetric
Storage The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
Catalog no. (Mfr.) VK175018
Main SKU BHE21400596

Product Overview

The Human Anti-Hepatitis D Virus/HDV IgG ELISA Kit quantifies human IgG antibodies against Hepatitis D Virus/HDV in serum and plasma. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.

Values are expressed relative to the antibody standard supplied with the kit.

Specifications

Assay Type Quantitative
Detection Method Colorimetric (OD 450 nm)
Sample Type Serum, Plasma
Sensitivity 0.25 ng/mL
Detection Range 1.56 - 100 ng/mL
Recovery 80-120%
Kit Size 96 T
Shipping 2-8 °C

Kit Components

Component Quantity
ELISA Microtiter plate 96 wells
HRP Conjugate 12 mL
Sample Diluent 12 mL
20×Concentrated Wash Buffer 50 mL
Substrate Reagent A 6 mL
Substrate Reagent B 6 mL
Stop Solution 6 mL
Positive Control 1 mL
Negative Control 1 mL
Plate Sealer 3 pieces
Sealed Bag 1 piece
Manual 1 copy

Assay Procedure

Bring all reagents and samples to room temperature (25 °C) before use. All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. The unused ELISA Microtiter plate should be sealed as soon as possible and stored at 2-8 °C.

  1. Number the sample and control in order, and keep a record of control wells and sample wells. Set 1 well for blank control, 3 wells for negative control and 2 wells for positive control (A blank well is not needed with dual-wavelength reading). Run samples in duplicate.
  2. A) Add 100 µL positive/negative control to positive/negative control well, keep the blank control well empty. b) Dilute the tested Serum with Sample Diluent at 1:10 into sample well (add 100 µL of sample diluent and add 10 µL of serum sample), mix fully.
  3. Gently tap the plate to mix thoroughly. Cover the ELISA Microtiter plate with sealer. Incubate for 30 min at 37 °C protected from light.
  4. Remove the plate sealer and aspirate the liquid of each well. Repeat the washing procedure for 5 times with Wash Buffer and immerse for 30-60 s each time. Invert the plate and pat it against thick clean absorbent paper (If bubbles exist in the wells, clean tips can be used to prick them).
  5. Add 100 µL of HRP Conjugate to each well except the blank control well, mix fully.
  6. Gently tap the plate to mix thoroughly, cover the ELISA Microtiter plate with sealer. Incubate for 30 minutes at 37 °C protected from light.
  7. Repeat step 4.
  8. Add 50 µL of Substrate Reagent A and 50 µL of Substrate Reagent B to each well. Gently tap the plate to mix thoroughly. Cover with a new plate sealer. Incubate for 15 min at 37 °C protected from light.
  9. Add 50 µL of Stop Solution to each well, gently tap the plate to mix thoroughly.
  10. Set the microplate reader wavelength at 450 nm (it is recommended to set the dual wavelength at 450 nm/630 nm) to detect A value of each well. Blank well is not essential when using dual wavelength 450 nm/630 nm for detection. Note: Read the results within 10 min.

Required but not supplied: a microplate reader for 450 nm (dual wavelength 450 nm / 630 nm recommended), precision pipettes and tips, a 37 °C incubator or water bath, deionized or distilled water, and absorbent paper.

Storage & Handling

Ships at 2-8 °C. Store the kit at 2-8 °C and do not freeze. Once opened, keep the plate at 2-8 °C and use it within 1 month. Bring reagents to room temperature before use and do not mix components from different kit lots.

For Research Use Only. Not for use in diagnostic procedures.

Q.Which sample types can be tested?
A.The kit is intended for serum and plasma. Validate dilution and recovery before running a new matrix.
Q.What are the detection range and sensitivity?
A.The detection range is 1.56 - 100 ng/mL and the sensitivity is 0.25 ng/mL. Dilute samples so readings fall within the standard curve.
Q.Can the plate be used partially?
A.Yes. Unused strips can be removed from the frame, returned to the foil pouch with the desiccant and resealed for later use.
Q.How should the kit be stored?
A.Ships at 2-8 °C. Store the kit at 2-8 °C and do not freeze. Once opened, keep the plate at 2-8 °C and use it within 1 month. Bring reagents to room temperature before use.
Q.Is this kit for diagnostic use?
A.No. This product is for research use only and is not intended for diagnostic or therapeutic procedures.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today