Assay Principle
This sandwich ELISA quantifies human cartilage oligomeric matrix protein (gene COMP) in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Strips are pre-coated with a capture antibody. After the sample is added, a biotinylated detection antibody binds the captured protein, and an avidin–biotin–peroxidase complex supplies the enzyme. TMB develops color in proportion to the bound target; the reaction is stopped and read at 450 nm, and concentrations are read from the standard curve.
Cartilage oligomeric matrix protein (COMP, thrombospondin-5) is a pentameric extracellular matrix glycoprotein abundant in cartilage, tendon and ligament. It binds collagens and fibronectin to stabilize the matrix, mutations cause pseudoachondroplasia, and COMP is often measured as a marker of cartilage turnover in arthritis research.
Kit Components
| Anti-Human COMP Pre-coated 96-well strip microplate | 1 plate (96 wells) |
|---|---|
| Human COMP Standard | 2 vials, 10 ng/tube |
| Human COMP Biotinylated antibody (100x) | 100 µL |
| Avidin-Biotin-Peroxidase Complex (100x) | 100 µL |
| Sample Diluent | 30 mL |
| Antibody Diluent | 12 mL |
| Avidin-Biotin-Peroxidase Diluent | 12 mL |
| Color Developing Reagent (TMB) | 10 mL |
| Stop Solution | 10 mL |
| Wash Buffer (25x) | 20 mL |
| Adhesive plate sealers | 4 |
Also required (not supplied): microplate reader for 450 nm; incubator; automated plate washer (optional); precision pipettes for 0.5 µL through 1 mL volumes of aqueous solutions; multichannel pipettes (recommended for many samples); deionized or distilled water; 500 mL graduated cylinders; test tubes for dilution.
Kit components are not sold separately.
Performance Data
| Species | Human |
|---|---|
| Sample types | Cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA) |
| Assay range | 156 pg/mL–10,000 pg/mL |
| Sensitivity | <10 pg/mL |
| Standard | Recombinant human COMP (Gln21–Ala757), expressed in NS0 |
| Cross-reactivity | None detected against related proteins in supplier testing |
| Intra-assay CV | 4.2–6.9% (3 samples, n = 16 each) |
| Inter-assay CV | 4.9–7.3% (3 samples, n = 24 each) |
| Format | 96 wells, removable strips |
Sample dilution: start at 1:5000. In the supplier’s tests, serum samples measured about 4000 ng/mL.
Example standard curve (OD450, pg/mL): 0 = 0.02; 156 = 0.066; 312 = 0.12; 625 = 0.231; 1250 = 0.462; 2500 = 0.918; 5000 = 1.816; 10000 = 2.572. Run a new standard curve on every plate.
Storage & Handling
Store at 4 °C for up to 6 months or −20 °C for up to 12 months. Avoid repeated freeze–thaw cycles. Ships on gel ice and tolerates up to 3 days at room temperature; freeze on arrival.
Safety
Sample data
| Concentration (pg/ml) | 0 | 156 | 312 | 625 | 1250 | 2500 | 5000 | 10000 |
| O.D. | 0.02 | 0.066 | 0.12 | 0.231 | 0.462 | 0.918 | 1.816 | 2.572 |
Intra/inter assay consistency
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 233 | 1997 | 4935 | 255 | 1893 | 5413 |
| Standard deviation | 9.78 | 137.79 | 246.75 | 12.49 | 138.18 | 281.47 |
| CV (%) | 4.2% | 6.9% | 5% | 4.9% | 7.3% | 5.2% |
Kit components
Description|Quantity Pre-coated 96-well strip microplate|1 Standard|2 vials Biotinylated antibody (100x)|100ul Avidin-Biotin-Peroxidase Complex (100x)|100ul Sample Diluent|30ml Antibody Diluent|12ml Avidin-Biotin-Peroxidase Diluent|12ml Color Developing Reagent (TMB)|10ml Stop Solution|10ml Wash Buffer (25x)|20ml Adhesive plate sealers|4Materials required but not provided
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.
Matthew S. Harkey et al. (2020) Sex-Specific Associations between Cartilage Structure and Metabolism at Rest and Acutely Following Walking and Drop-Landing. Cartilage. 10.1177/1947603520959386
Akinmade Akinola et al. (2021) Serum cartilage oligomeric matrix protein as a biomarker for predicting development and progression of knee osteoarthritis. International Orthopaedics. 10.1007/s00264-021-04943-4
Domen Plut et al. (2020) Detection and evaluation of haemophilic arthropathy: Which tools may be considered more reliable. Haemophilia. 10.1111/hae.14153
Jian Wu et al. (2017) Platelet-rich plasma inhibits Wnt/β-catenin signaling in rabbit cartilage cells activated by IL-1β. International Immunopharmacology. 10.1016/j.intimp.2017.12.031
Pu Wang et al. (2015) Effects of Whole Body Vibration Exercise associated with Quadriceps Resistance Exercise on functioning and quality of life in patients with knee osteoarthritis: a randomized controlled trial. Clinical Rehabilitation. 10.1177/0269215515607970
Brittney A. Luc-Harkey et al. (2018) Lesser lower extremity mechanical loading associates with a greater increase in serum cartilage oligomeric matrix protein following walking in individuals with anterior cruciate ligament reconstruction. Clinical Biomechanics. 10.1016/j.clinbiomech.2018.09.024