Scientific Background
This ELISA kit applies to the in vitro quantitative determination of Human HO1 concentrations in serum, plasma and other biological fluids.
Assay Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human HO1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human HO1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human HO1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human HO1. You can calculate the concentration of Human HO1 in the samples by comparing the OD of the samples to the standard curve.
Performance Specifications
| Sensitivity | 0.19 ng/mL |
|---|---|
| Detection Range | 0.31-20 ng/mL |
| Total Assay Time | 3 h 30 min |
| Compatible Sample Types | Serum, plasma and other biological fluids |
| Species Reactivity | Human |
| Detection Method | Sandwich |
| Precision (CV) | Both intra-CV and inter-CV are < 10%. |
| Recovery Rate | 80%-120% |
| Storage | 2-8℃,12 months |
✓ Research-Grade Validation
Specificity
This kit recognizes Human HO1 in samples. No significant cross-reactivity or interference between Human HO1 and analogues was observed
Safety & Regulatory
Handle reagents in accordance with institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for complete hazard and handling information. Contains components that may require special disposal procedures per local regulations.
This kit is validated for use with Serum, plasma and other biological fluids. For unlisted matrices (e.g., tissue lysate, urine), perform a spike-and-recovery experiment to confirm assay performance before generating reportable data. Sample dilution in the kit's provided diluent is recommended to minimize matrix interference.
The minimum detectable concentration (sensitivity) of this kit is 0.19 ng/mL. Values below this threshold should be reported as below the limit of detection (<LOD) and should not be extrapolated from the standard curve.
The total assay time from sample addition to absorbance reading is approximately 3 h 30 min, including all incubation, wash, and substrate steps. Hands-on time is typically 1–2 hours; most steps involve passive plate incubation. Plan the assay as a single uninterrupted session for best results.
Standard components of this Sandwich ELISA Kit typically include: pre-coated microplate (96-well strip format), lyophilized or liquid recombinant HO1 standard, detection antibody, streptavidin-HRP conjugate, TMB substrate, stop solution, wash buffer concentrate, and sample/standard diluent. Refer to the kit insert or datasheet for the exact component list and storage requirements.
This kit uses colorimetric (TMB/HRP) detection and requires a standard microplate absorbance reader capable of measuring at 450 nm. A reference wavelength of 570 nm or 630 nm is recommended to reduce background. No specialized fluorescence or luminescence reader is needed. Ensure the instrument is calibrated and the plate is clean and free of condensation before reading.
Tissue samples may contain endogenous or exogenous proteases during processing, leading to degradation of extracted proteins. Therefore, it's necessary to add protease inhibitors during processing to ensure the integrity of target proteins. If customers can keep samples cold and handle them quickly during processing, omitting the protease inhibitor may not have a significant effect. After preparation, samples should be tested promptly or immediately aliquoted and frozen at -20°C or -80°C.
What is the range of enzyme activity of your IL-2 freeze-dried powder
What is the principle of adding stop solution to stop color reaction in ELISA experiment?
Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.
Mesenchymal stromal cells plus basiliximab improve the response of steroid-refractory acute graft-versus-host disease as a second-line therapy: a multicentre, randomized, controlled trial (2024) BMC Medicine. 10.1186/s12916-024-03275-5
Identification of Penexanthone A as a Novel Chemosensitizer to Induce Ferroptosis by Targeting Nrf2 in Human Colorectal Cancer Cells (2024) Marine Drugs. 10.3390/md22080357
The promoter T-413A variant and elevated enzyme levels of heme oxygenase-1 associated with an increased risk of polycystic ovarian syndrome (2025) Frontiers in Endocrinology. 10.3389/fendo.2025.1644373
Zinc oxide nanoparticle-induced atherosclerotic alterations in vitro and in vivo (2017) International Journal of Nanomedicine. 10.2147/IJN.S134897
Multifunctional pectin derivatives as anticancer agents in colorectal cancer via synthesis, computational insights, and modulation of NRF2/HO-1,?HIF-1α, and VEGF/PDGF-D signaling pathways (2026) Scientific Reports. 10.1038/s41598-025-32107-6
Relationship between Brain Tissue Changes and Blood Biomarkers of Cyclophilin A, Heme Oxygenase-1, and Inositol-Requiring Enzyme 1 in Patients with Alzheimer’s Disease (2021) Diagnostics. 10.3390/diagnostics11050740
Overexpression of the transcription factor FOXP3 in lung adenocarcinoma sustains malignant character by promoting G1/S transition gene CCND1 (2015) TUMOR BIOLOGY. 10.1007/s13277-015-4616-3
KDM3A promotes inhibitory cytokines secretion by participating in TLR4 regulation of Foxp3 transcription in lung adenocarcinoma cells (2017) Oncology Letters. 10.3892/ol.2017.5949
Heme oxygenase-1 in osteosarcoma (2020) Journal of Cancer Research and Therapeutics. 10.4103/jcrt.JCRT_419_17
Evaluation of Oxidative Stress, Antioxidant Capacity, Thiol/Disulfide Homeostasis, and HO-1 Levels in Neonates with Cyanotic Congenital Heart Disease: A Prospective Case-Control Study (2025) AMERICAN JOURNAL OF PERINATOLOGY. 10.1055/a-2656-9689