Assay Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human SOST. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human SOST and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human SOST, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human SOST. You can calculate the concentration of Human SOST in the samples by comparing the OD of the samples to the standard curve.
Performance Specifications
| Sensitivity | 37.5 pg/mL |
|---|---|
| Detection Range | 62.5-4000 pg/mL |
| Total Assay Time | 3 h 30 min |
| Compatible Sample Types | Serum, plasma and other biological fluids |
| Species Reactivity | Human |
| Detection Method | Sandwich |
| Precision (CV) | Both intra-CV and inter-CV are < 10%. |
| Recovery Rate | 80%-120% |
| Storage | 2-8℃,12 months |
✓ Research-Grade Validation
Specificity
This kit recognizes Human SOST in samples. No significant cross-reactivity or interference between Human SOST and analogues was observed
Safety & Regulatory
Handle reagents in accordance with institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for complete hazard and handling information. Contains components that may require special disposal procedures per local regulations.
This kit is validated for use with Serum, plasma and other biological fluids. For unlisted matrices (e.g., tissue lysate, urine), perform a spike-and-recovery experiment to confirm assay performance before generating reportable data. Sample dilution in the kit's provided diluent is recommended to minimize matrix interference.
The minimum detectable concentration (sensitivity) of this kit is 37.5 pg/mL. Values below this threshold should be reported as below the limit of detection (<LOD) and should not be extrapolated from the standard curve.
The total assay time from sample addition to absorbance reading is approximately 3 h 30 min, including all incubation, wash, and substrate steps. Hands-on time is typically 1–2 hours; most steps involve passive plate incubation. Plan the assay as a single uninterrupted session for best results.
Standard components of this Sandwich ELISA Kit typically include: pre-coated microplate (96-well strip format), lyophilized or liquid recombinant SOST standard, detection antibody, streptavidin-HRP conjugate, TMB substrate, stop solution, wash buffer concentrate, and sample/standard diluent. Refer to the kit insert or datasheet for the exact component list and storage requirements.
This kit uses colorimetric (TMB/HRP) detection and requires a standard microplate absorbance reader capable of measuring at 450 nm. A reference wavelength of 570 nm or 630 nm is recommended to reduce background. No specialized fluorescence or luminescence reader is needed. Ensure the instrument is calibrated and the plate is clean and free of condensation before reading.
Tissue samples may contain endogenous or exogenous proteases during processing, leading to degradation of extracted proteins. Therefore, it's necessary to add protease inhibitors during processing to ensure the integrity of target proteins. If customers can keep samples cold and handle them quickly during processing, omitting the protease inhibitor may not have a significant effect. After preparation, samples should be tested promptly or immediately aliquoted and frozen at -20°C or -80°C.
What is the range of enzyme activity of your IL-2 freeze-dried powder
What is the principle of adding stop solution to stop color reaction in ELISA experiment?
Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.
Colchicine Blocks Abdominal Aortic Aneurysm Development by Maintaining Vascular Smooth Muscle Cell Homeostasis (2024) International Journal of Biological Sciences. 10.7150/ijbs.93544
Evaluation of GCF IL-17, IL-10, TWEAK, and sclerostin levels after scaling and root planing and adjunctive use of diode laser application in patients with periodontitis (2021) JOURNAL OF PERIODONTOLOGY. 10.1002/JPER.21-0494
The serum level of sclerostin decreases in radiographic axial spondyloarthritis patients with fatty lesions (2025) ARTHRITIS RESEARCH & THERAPY. 10.1186/s13075-025-03479-x
The Role of Sclerostin in Rheumatic Diseases: A Review (2023) Journal of Clinical Medicine. 10.3390/jcm12196248
Evaluation of gingival crevicular fluid and peri-implant crevicular fluid levels of sclerostin, TWEAK, RANKL and OPG (2018) CYTOKINE. 10.1016/j.cyto.2018.10.021
Comparative Analysis of Vascular Calcification Risk Factors in Pre-Hemodialysis and Prevalent Hemodialysis Adult Patients: Insights into Calcification Biomarker Associations and Implications for Intervention Strategies in Chronic Kidney Disease (2024) Diagnostics. 10.3390/diagnostics14080824
Mountain Bike Racing Stimulates Osteogenic Bone Signaling and Ingesting Carbohydrate-Protein Compared With Carbohydrate-Only Prevents Acute Recovery Bone Resorption Dominance (2020) JOURNAL OF STRENGTH AND CONDITIONING RESEARCH. 10.1519/JSC.0000000000003928
Changes in Dickkopf-1, but Not Sclerostin, in Gingival Crevicular Fluid Are Associated with Peroral Statin Treatment in Patients with Periodontitis (2024) Medicina-Lithuania. 10.3390/medicina60030508
Evaluation of serum fibroblast growth factor-23 in patients with axial spondyloarthritis and its association with sclerostin, inflammation, and spinal damage (2019) RHEUMATOLOGY INTERNATIONAL. 10.1007/s00296-019-04298-5
Serum sclerostin levels as a diagnostic marker for osteoporosis (2024) Bioinformation. 10.6026/973206300200054
Is serum sclerostin a marker of atherosclerosis in patients with chronic kidney disease–mineral and bone disorder? (2018) INTERNATIONAL UROLOGY AND NEPHROLOGY. 10.1007/s11255-018-1935-5
The correlation between sclerostin and bone mineral density in renal transplant recipients (2020) NEFROLOGIA. 10.1016/j.nefro.2020.04.009
Inhibitors of osteoblastogenesis in early human milk and maternal serum: evidence for protective properties of mother’s milk on bone (2018) Journal of Maternal-Fetal & Neonatal Medicine. 10.1080/14767058.2018.1514383
Sclerostin and osteoprotegerin: new markers of chronic kidney disease mediated mineral and bone disease in children (2020) JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM. 10.1515/jpem-2020-0140
Significance of acPWV for Survival of Hemodialysis Patients (2020) Medicina-Lithuania. 10.3390/medicina56090435
Comparative Evaluation of Sclerostin Levels in Gingival Crevicular Fluid in the Treatment of Chronic Periodontitis Patients Using Diode Laser as an Adjunct to Scaling and Root Planing: A Clinico-biochemical Study (2021) Contemporary Clinical Dentistry. 10.4103/ccd.ccd_19_20
Serum Sclerostin Levels in Rheumatoid Arthritis and Correlation with Disease Activity and Bone Mineral Density (2019) Indian Journal of Rheumatology. 10.4103/injr.injr_113_18