Mouse NOS2/iNOS (Nitric Oxide Synthase 2, Inducible) ELISA Kit

SKU:BHE10802409
Overview
Click light‑blue chips for details
Quantitative double-antibody sandwich ELISA kit for measuring mouse NOS2/iNOS (Nitric Oxide Synthase 2, Inducible) in Serum, Plasma, Cell Culture Supernatant, and cell or tissue lysate. Includes sensitivity 0.188ng/mL, detection range 0.313–20ng/mL for signal transduction research.
Target NOS2/iNOS
Species Mouse
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Assay Type Sandwich ELISA, Double Antibody
Sensitivity 0.188ng/ml
Detection Range 0.313-20ng/ml
Assay Time 4 hours
Options selector
Catalog no. Size
EM0272-96T 96 T
Available Options

Select the variant options shown for this product and review lead time and shipping expectations before ordering.

  • Size: 96 tests (96T) kit.
  • Lead time: options listed as “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: 2-8 °C for 12 months; ships cold (typically with ice packs) is expected.
  • Please ensure someone is available to receive and store the shipment promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No EM0272
Alternative Names Nitric oxide synthase, inducible|Hepatocyte NOS|HEP-NOS|Inducible NO synthase|Inducible NOS, iNOS|NOS type II|Peptidyl-cysteine S-nitrosylase NOS2|NOS2|NOS2A
Assay Time
  • 4 hours
Detection Method
  • Sandwich ELISA
  • Double Antibody
Detection Range 0.313-20ng/ml
Product Type
  • ELISA Kits
Reactivity
  • Mouse
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Sensitivity 0.188ng/ml
Species Mouse
Storage 2-8 °C for 12 months
Target NOS2/iNOS
UniProt # P29477

Background

mouse NOS2/iNOS (Nitric Oxide Synthase 2, Inducible) is a molecular target commonly studied in signal transduction, neuroscience, and metabolism research. Many proteins are studied as molecular readouts that can change with cellular state, tissue remodeling, or stress responses.

Biological role and mechanism

The biological role of NOS2/iNOS is typically understood in terms of its molecular category and interaction network. Depending on the model system, it may participate in cell–cell communication, intracellular signaling, enzymatic processing, or regulation of gene expression programs. Mechanistic interpretation is often strengthened by considering upstream regulators and downstream readouts rather than relying on a single marker.

Expression and abundance of NOS2/iNOS can vary by tissue, cell type, and physiological state. In many systems, levels are influenced by factors such as developmental stage, immune activation, metabolic status, and cellular stress. Because sample matrix and pre-analytical handling can affect measured concentrations, interpretation is typically strongest when experiments keep collection and processing consistent across groups.

Nomenclature and related terms

NOS2/iNOS (Nitric Oxide Synthase 2, Inducible) may also be referenced as Nitric oxide synthase, inducible, Hepatocyte NOS, and HEP-NOS in the literature or in databases. When comparing results across studies, confirm that the reported analyte refers to the same molecule, species context, and molecular form (e.g., precursor vs mature protein, or soluble vs membrane-associated forms).

Why it matters in research

  • Understanding how NOS2/iNOS relates to neuronal signaling and synaptic function, neuroinflammation, neurodegeneration models, and brain–body communication in signal transduction, neuroscience, and metabolism research.
  • Interpreting shifts in NOS2/iNOS levels alongside other pathway components or complementary markers.
  • Connecting molecular changes to phenotypes such as inflammation, remodeling, metabolism shifts, or cell-state transitions (context-dependent).

Molecular forms and interpretation

For some targets, isoforms, proteolytic processing, or post-translational modifications (such as phosphorylation or glycosylation) can influence function and apparent abundance. If multiple molecular forms are expected in your model, align interpretation with the form most relevant to the biological question.

Disease and translational relevance

NOS2/iNOS has been investigated across diverse physiological and disease contexts, and changes in its abundance have been reported in areas aligned with signal transduction, neuroscience, and metabolism studies. These associations are interpreted as research findings rather than diagnostic or therapeutic claims, and they should be evaluated alongside model-specific covariates and study design.

?What?s the plate size in FineTest? ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
?How about the shelf life and stability of FineTest? ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest? ELISA Kits have been subject to strict quality test.
?Which cloned antibodies for FineTest? ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
?Can I mix reagents from different batches of FineTest? ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
?Can FineTest? ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
?How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
?Can standard curve be extended to any direction?
FineTest? can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
?Why does detection for serum/plasma sample by FineTest? ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
?What?s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest? can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
?What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

CXCL16/CXCR6/TGF‐β Feedback Loop Between M‐MDSCs and Treg Inhibits Anti‐Bacterial Immunity During Biofilm Infection

IF: 14.1 Journal: Advanced Science Author: Department of Joint Surgery, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, Guangdong, 510080, China. Cited Date: 2025-10-24

Identification of potential anti-pneumonia pharmacological components of Glycyrrhizae Radix et Rhizoma after the treatment with Gan An He Ji oral liquid

IF: 14.026 Journal: Journal of Pharmaceutical Analysis Cited Date: 2022-08-11

Bioengineered chondrocyte membrane-camouflaged anti-ferroptotic drug-loaded liposomes: A highly effective cartilage-targeted drug delivery system for osteoarthritis treatment

IF: 13.3 Journal: Chemical Engineering Journal Author: National & Local Joint Engineering Research Center of Orthopaedic Biomaterials, Peking University Shenzhen Hospital, Shenzhen, Guangdong, PR China Cited Date: 2024-09-20

Fe-Capsaicin Nanozymes Attenuate Sepsis-Induced Acute Lung Injury via NF-κB Signaling

IF: 8 Journal: International Journal of Nanomedicine Author: Emergency Department, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, People’s Republic of China Cited Date: 2024-01-12

Paeonol inhibits ACSL4 to protect chondrocytes from ferroptosis and ameliorates osteoarthritis progression

IF: 5.9 Journal: Journal of Orthopaedic Translation Author: National & Local Joint Engineering Research Centre of Orthopaedic Biomaterials, Peking University Shenzhen Hospital, Shenzhen, Guangdong, China Cited Date: 2024-12-06

Schisandrin A restrains osteoclastogenesis by inhibiting reactive oxygen species and activating Nrf2 signalling

IF: 5.753 Journal: Cell Proliferation Cited Date: 2020-09-01

Inhibition of RAC1 activator DOCK2 ameliorates cholestatic liver injury via regulating macrophage polarisation and hepatic stellate cell activation

IF: 5.7 Journal: Biology Direct Author: Department of Pediatrics, The First Affiliated Hospital of Henan University of Chinese Medicine, Zhengzhou, Henan, China. Cited Date: 2025-04-25

Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today