| Field | Specification |
|---|---|
| Applications | |
| Storage | |
| Catalog no. (Mfr.) | |
| Main SKU |
Background
Mycoplasma contamination is one of the most common and serious problems in cell culture, in both research laboratories and industry. The manufacturer cites a conservative estimate that around 15–35% of all continuous cell cultures are contaminated. Mycoplasma are among the smallest and simplest self-replicating prokaryotes, cannot be seen by visual inspection of the culture, and gradually affect cell growth and alter DNA, RNA and protein synthesis in the host cells.
Product Description
Mycoplasma Prevention Solution is designed to prevent mycoplasma contamination in cultured cells when added to the culture medium. Its activity is stable in culture medium and is not affected by penicillin, streptomycin or serum, and the manufacturer states that the solution shows no toxicity to cultured cells.
Specifications
| Product Format | Ready-to-use solution at stock concentration |
|---|---|
| Working Dilution | 1:2000 from stock (0.25 mL into 500 mL medium) |
| Sterility | Sterilized and filtered with 0.2 µm filter |
| Compatibility | Activity not affected by penicillin, streptomycin or serum |
| Treatment Period | At least one week of continuous culture |
| Size | 2 x 1 mL |
| Storage | Store at -20°C on arrival for long-term use. The solution is stable for 2 weeks at 4°C and at least one year at -20°C. Avoid repeated freeze-thaw cycles. |
Contents and Sterility
Mycoplasma Prevention Solution supplied at a stock concentration, as 2 x 1 mL. The solution is sterilized and filtered through a 0.2 µm filter.
Suggested Protocol
Cells should already be mycoplasma free and the working environment cleaned with 70% ethanol before use.
- Decontaminate the outside of the tube by spraying with 70% ethanol.
- Add 0.25 mL of Mycoplasma Prevention Solution to 500 mL of culture medium, a 1:2000 dilution from the stock concentration, under aseptic conditions.
- Remove the old medium from the plate and replace it with fresh medium containing the solution, in the volume needed.
- Change the medium every other day. For stem cells or iPS cells, change it every day.
- Culture the cells in the solution for at least one week and test frequently by mycoplasma qPCR detection.
Applications
Prevention of mycoplasma contamination in cultured cells.
Safety & Handling
Can’t find the exact format you need? We can help you source or support mycoplasma control in cell culture — including bulk or repeat-order volumes, qPCR detection kits for routine monitoring, and reagents for treating a culture that is already contaminated. Click Talk to a Scientist, email support@biohippo.com, or explore our Research Services. Our team will be in contact shortly.