| Field | Specification |
|---|---|
| Species | |
| Applications | |
| Sample type(s) | Chemicals with carbonyl groups (e.g. ketones, aldehydes) or protein carbonyls in biological samples (e.g. oxidized BSA, etc.) |
| Detection limit | |
| Detection method | |
| Plate format | |
| Assay time | |
| Storage | |
| Shelf life | |
| Shipping | |
| Catalog no. (Mfr.) | |
| Main SKU |
Overview
For quantitative determination of carbonyl groups or protein carbonyls and evaluation of drug modulators. The assay uses OD375nm for signal readout. Compatible sample input includes Chemicals with carbonyl groups (e.g. ketones, aldehydes) or protein carbonyls in biological samples (e.g. oxidized BSA, etc.). Typical stated assay timing is 30 min.
Key elements and design rationale
- Readout format: OD375nm supports plate-based signal acquisition and consistent comparison across matched samples.
- Sample compatibility: The stated sample scope includes Chemicals with carbonyl groups (e.g. ketones, aldehydes) or protein carbonyls in biological samples (e.g. oxidized BSA, etc.), which is useful when aligning matrix type with calibration and control design.
- Analytical range context: The supplied specifications include a stated detection limit of 12 µM for interpreting low-signal samples.
- Feature emphasis: Fast and sensitive. Use of 100 µL sample. Linear detection range from 12 to 250 µM carbonyl in 96-well plate assay.
Additional feature notes highlight Convenient. The procedure involves adding a single working reagent, and reading the absorbance after 30 min; High-throughput. Homogeneous “mix-incubate-measure” type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Available format information for this listing includes 100 Tests.
Biological background
This product is centered on measurement of carbonyl within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.
More details
CARBONYL groups, such as ketones and aldehydes, are a commonindicator of protein oxidation. Protein oxidation is caused as a result of exposure to reactive oxygen species (ROS) and is a common marker in various diseases as well as aging. BioAssay Systems’ Carbonyl Assay Kit is based on an improved method, where 2,4-dinitrophenylhydrazine (DNPH) reacts with carbonyl groups to produce a colored compound at 375 nm. The intensity of this colored compound is directly proportional to the carbonyl groups in the sample.
Detection method
Colorimetric (OD 375 nm).
Detection limit and analytical sensitivity
Reported detection limit: 12 µM.
Procedures and timing
Stated procedure or timing information: 30 min.
Research relevance and current trends
- Plate-based quantification and side-by-side group comparison remain central use cases for this assay format.
- The product notes emphasize multi-sample throughput, making it relevant for screening-oriented and larger batch comparison studies.
- The description supports intervention-focused study designs in which researchers compare baseline and perturbed conditions.
Common research applications
- Quantify carbonyl in chemicals with carbonyl groups (ketones by OD375 nm readout.
- Compare treatment or phenotype groups using matched chemicals with carbonyl groups (ketones handling.
- Monitor time-course or pre/post changes in chemicals with carbonyl groups (ketones across study conditions.
Interpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.
Notes for experimental interpretation
- Matrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.
- Use appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.
The background is very high. Is this normal?
The background absorbance is typically ~ 0.5. This is completely normal.
Can I store the diluted standards (250 µM, 150 µM, 75 µM, and 0 µM) to use for later?
We recommend preparing the standards fresh from the 50 mM each day.
Do I need to run a standard curve with every assay?
Yes.
How should I store the kit?
The kit is shipped at room temperature. Upon delivery, store at -20°C.
Precipitate formed when I added the reagent to the sample. What should I do?
The Reagent is acidic and may cause precipitation in samples that have significant amounts of protein. You may need to dilute your sample, repeat the assay, and correct for the dilution factor in the calculation.
What is the Carbonyl Standard?
The standard is pyruvate, which has two carbonyl groups per molecule. So the 50 mM Carbonyl Standard is actually 25 mM pyruvate.
My sample has high levels of nucleic acids. Will this interfere?
Nucleic acids can artificially increase the carbonyl count if they are present in high levels. If the ratio of 280/260 nm is less than 1, samples should be mixed with 1% streptomycin sulfate to denature the nucleic acids. Mix well, incubate the samples at room temperature for 15 minutes and then centrifuge at 5000xg for 10 minutes. Use the supernatant in the assay.
For laboratories requiring additional technical capacity, we provide scientific support services including assay execution, method guidance, product sourcing, and customization to align the assay with specific experimental objectives. If you need assistance selecting the appropriate kit configuration, adapting the workflow to your application, or identifying related research services, please click Talk to a Scientist, email support@biohippo.com, or review our Research Services; a member of our scientific team will follow up with recommendations tailored to your study.