| Field | Specification |
|---|---|
| Species | |
| Applications | |
| Sample type(s) | Plasmid DNA, genomic DNA, cDNA, DNA following polymerase chain reaction, and DNA extracted from gel and other matrices |
| Detection limit | |
| Detection method | |
| Plate format | |
| Assay time | |
| Storage | |
| Shelf life | |
| Shipping | |
| Catalog no. (Mfr.) | |
| Main SKU |
Overview
For quantitative determination of DNA. The assay uses FL350/450nm for signal readout. Compatible sample input includes Plasmid DNA, genomic DNA, cDNA, DNA following polymerase chain reaction, and DNA extracted from gel and other matrices. Typical stated assay timing is 5 min.
Key elements and design rationale
- Readout format: FL350/450nm supports plate-based signal acquisition and consistent comparison across matched samples.
- Sample compatibility: The stated sample scope includes Plasmid DNA, genomic DNA, cDNA, DNA following polymerase chain reaction, and DNA extracted from gel and other matrices, which is useful when aligning matrix type with calibration and control design.
- Analytical range context: The supplied specifications include a stated detection limit of 100 ng/mL for interpreting low-signal samples.
- Feature emphasis: Sensitive and accurate. Linear detection range 2 ng to 40 ng (100 – 2,000 ng/mL) calf thymus DNA in 96-well plate assay.
Additional feature notes highlight Simple and high-throughput. The “mix-and-read” procedure involves addition of a single working reagent and reading the fluorescence intensity. Can be readily automated as a high-throughput assay for thousands of samples per day; Low interference. RNA, salt (up to 3M NaCl), detergent (< 0.01% SDS) and common DNA extraction buffer do not interfere in the assay. Available format information for this listing includes 250 Tests.
Biological background
This product is centered on measurement of dna within the matrices described for the assay. In practice, datasets from this type of format are typically interpreted by comparing relative signal, activity, or abundance across matched control and experimental groups rather than relying on a single value in isolation. Careful alignment of sample matrix, incubation window, and calibration strategy is important when comparing results across plates, operators, or study days.
More details
DNA quantitation is a common practice in molecular biology. Very often DNA is available in minute quantities and the traditional UV 260 nm absorbance method requires microgram quantities for reliable results. Accurate determination of DNA concentration, especially when DNA is present at low concentrations, is crucial for reproducible results in sequencing, cloning, transfection and DNA labeling. Simple, direct and automation-ready procedures for measuring DNA concentration are very desirable. BioAssay Systems QuantiFluo™ DNA assay kit is designed to accurately measure nanogram quantities of plasmid DNA, cDNA, DNA following polymerase chain reaction and DNA eluted from gels. The improved method utilizes Hoechst dye that binds specifically with double-stranded DNA. The fluorescence intensity, measured at λex/em = 350/450nm, is directly proportional to the DNA concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw samples.
Detection method
Fluorescent (FL 350/450 nm).
Detection limit and analytical sensitivity
Reported detection limit: 100 ng/mL.
Procedures and timing
Stated procedure or timing information: 5 min.
Research relevance and current trends
- Plate-based quantification and side-by-side group comparison remain central use cases for this assay format.
- The product notes emphasize multi-sample throughput, making it relevant for screening-oriented and larger batch comparison studies.
- Short assay timing and plate compatibility support time-course or repeated-measure collection plans when handling is kept consistent.
Common research applications
- Quantify dna in plasmid DNA, genomic DNA, cDNA by FL350/450 nm readout.
- Compare treatment or phenotype groups using matched plasmid DNA, genomic DNA, cDNA handling.
- Monitor time-course or pre/post changes in plasmid DNA, genomic DNA, cDNA across study conditions.
Interpretation is usually strongest when signal changes are assessed alongside matrix-matched controls, replicate agreement, and the assay's stated analytical window.
Notes for experimental interpretation
- Matrix composition, background signal, and sample handling can influence apparent response; compare like-with-like whenever possible.
- Use appropriate blanks, controls, and replicate wells to distinguish biological differences from plate, reagent, or handling variability.
Can you guarrantee, that your kit enables an accurate estimation of cDNA concentration in RT reaction mixture, where high excess of total RNA is present? Is it a SYBR Green based method?
We are using Hoechst dye based DNA assay. It is very specific for DNA and not RNA. However, as we do not know the RNA content in your sample, we can not judge if it would meet your needs.
For laboratories requiring additional technical capacity, we provide scientific support services including assay execution, method guidance, product sourcing, and customization to align the assay with specific experimental objectives. If you need assistance selecting the appropriate kit configuration, adapting the workflow to your application, or identifying related research services, please click Talk to a Scientist, email support@biohippo.com, or review our Research Services; a member of our scientific team will follow up with recommendations tailored to your study.
Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells
Mayer-Wagner S, et al (2011). Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells. Bioelectromagnetics. 32(4):283-90. Assay: DNA in human stem cell.
Some Biochemical Characteristics and Preservation of Epididymal Camel Spermatozoa (Camelus dromedarius)
Waheed MM et al (2011). Some Biochemical Characteristics and Preservation of Epididymal Camel Spermatozoa (Camelus dromedarius). Theriogenology 2011 Jul 13. Assay: DNA in human cell line.
Metformin has adenosine-monophosphate activated protein kinase (AMPK)-independent effects on LPS-stimulated rat primary microglial cultures
Labuzek K, et al (2010). Metformin has adenosine-monophosphate activated protein kinase (AMPK)-independent effects on LPS-stimulated rat primary microglial cultures. Pharmacol Rep. 62(5):827-48. Assay: DNA in rat microglial cells.
Ambivalent effects of compound C (dorsomorphin) on inflammatory response in LPS-stimulated rat primary microglial cultures
Labuzek K, et al (2010). Ambivalent effects of compound C (dorsomorphin) on inflammatory response in LPS-stimulated rat primary microglial cultures. Naunyn Schmiedebergs Arch Pharmacol. 381(1):41-57. Assay: DNA in rat primary glial culture.
Membrane-based cultures generate scaffold-free neocartilage in vitro: influence of growth factors
Mayer-Wagner S et al. (2010). Membrane-based cultures generate scaffold-free neocartilage in vitro: influence of growth factors. Tissue Eng Part A. 16(2):513-21. Assay: DNA in human cell.
Structure activity relationships and differential interactions and functional activity of various equine estrogens mediated via estrogen receptors (ERs) ERalpha and ERbeta