Rabies virus (RABV) Glycoprotein (G) ELISA Kit

SKU:BHE21400064
Suppliers
Biohippo Inc
Biohippo Inc
Details Products
Overview
Click light‑blue chips for details
Quantitative Colorimetric ELISA kit for quantitative measurement of Glycoprotein in Rabies virus (RABV) from Plasma, Serum samples. Designed for research assay development and biomarker studies; detection range 0.07 - 50 ng/mL, sensitivity 0.05 ng/mL.
Target Glycoprotein
Detection Range 0.07 - 50 ng/mL
Sensitivity 0.05 ng/mL
Detection Range 0.07 - 50 ng/mL
Species Rabies virus (RABV)
Options selector
Catalog no. Size
VK584018-96T 96 T
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 96 T
  • Lead time: options listed as "in stock at manufacturer" typically ship in 5-7 business days; other statuses may take longer.
  • Storage: The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: follow the product datasheet storage instructions.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No VK584018
Assay Type
  • Quantitative
Detection Method
  • Colorimetric
Detection Range 0.07 - 50 ng/mL
Product Type
  • ELISA Kits
Sample Type(s) Plasma, Serum
Sensitivity 0.05 ng/mL
Shipping 2-8 ℃
Species Rabies virus (RABV)
Storage The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
Target Glycoprotein

Overview

Rabies virus (RABV) Glycoprotein (G) ELISA Kit is an ELISA-based immunoassay designed for quantitative measurement of Glycoprotein (Rabies virus (RABV)) in research samples. It is commonly used to generate traceable concentration data for biomarker discovery, pathway studies, and comparative analyses across experimental conditions.

Key elements and design rationale

  • Assay format: Quantitative Colorimetric ELISA. The format defines how signal scales with analyte abundance and how results are interpreted across a standard curve.
  • Working range and sensitivity: dynamic range 0.07 - 50 ng/mL; analytical sensitivity 0.05 ng/mL. Use these values to plan dilutions and keep readouts within the linear portion of the calibration curve.
  • Sample compatibility: Intended for Plasma, Serum matrices. As with most immunoassays, matrix composition can influence apparent signal and should be evaluated with dilution linearity and spike-recovery concepts.
  • Recovery reference: Typical recovery is reported as 80-120%. Recovery helps assess whether the sample matrix interferes with detection of spiked analyte.

This kit is supplied for research use in laboratory settings where defined, quantitative readouts are needed for experimental interpretation.

Biological background

Glycoprotein is a commonly studied research analyte. Its biological roles and regulation can be context-dependent (cell type, tissue state, and experimental perturbation). For authoritative gene/protein function summaries and nomenclature, researchers typically consult curated databases.

Research relevance and current trends

  • Biomarker translation in RUO settings: Increasing use of quantitative immunoassays to stratify experimental cohorts, track longitudinal changes, and benchmark model systems.
  • Matrix-aware assay design: Greater emphasis on dilution linearity, spike-recovery, and control concepts to reduce matrix-driven artifacts in serum/plasma and complex lysates.
  • Integration with multi-omics: ELISA measurements are often used alongside transcriptomics and proteomics to connect abundance changes with pathway activity and phenotype.

Common research applications

  • Comparative quantification: Measure relative changes in analyte levels across treatments, time points, or genotypes to support mechanistic hypotheses.
  • Assay development and standardization: Generate reproducible concentration inputs for method qualification, inter-operator comparisons, or bridging studies across platforms.
  • Model and sample characterization: Profile baseline and stimulated levels to help interpret immune, endocrine, neurodegenerative, or metabolic phenotypes (as relevant to the target).

Interpretation typically focuses on direction and magnitude of change in the context of controls and sample handling metadata, rather than single-point absolute values.

Notes for experimental interpretation

  • Matrix effects: Hemolysis, lipemia, and high protein content can alter background and apparent concentration. Consider consistent collection/processing and evaluate dilution behavior.
  • Isoforms and modified forms: Some targets exist as isoforms, fragments, or post-translationally modified species. Ensure the measured form aligns with the biological question and the kit’s intended analyte definition.
  • Control concepts: Use negative/blank controls, replicate wells, and—when feasible—orthogonal confirmation (e.g., WB or MS) to strengthen conclusions.

What does this ELISA kit measure?

This sandwich ELISA kit is designed to quantitatively measure Glycoprotein in biological samples. It uses a validated antibody pair with high specificity for the target antigen, making it suitable for research in Infectious Disease applications.

What sample types are compatible with this kit?

This kit has been validated for use with Plasma and Serum. Samples should be diluted as recommended in the protocol to fall within the standard curve range. Cross-reactivity with other matrices has not been systematically evaluated and should be tested by the user.

What is the detection range and sensitivity of this kit?

The standard curve covers 0.07 - 50 ng/mL. The minimum detectable concentration (sensitivity/LLOD) is 0.05 ng/mL. Samples with expected concentrations outside this range should be diluted or concentrated accordingly.

How should I prepare my samples before running the assay?

Samples should be collected, processed, and stored according to established best practices for the matrix type. Avoid repeated freeze-thaw cycles. Centrifuge samples containing particulates at 2,000?3,000 ? g for 10 minutes. Dilute samples in the provided assay diluent and run in duplicate. Refer to the kit insert for recommended dilution factors.

Can this kit be used for clinical diagnostic purposes?

No. This kit is intended for research use only (RUO) and is not approved or validated for clinical diagnosis, patient management, or therapeutic monitoring. Results obtained with this kit should not be used to make clinical decisions.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today