Rat BCL-2 (B-Cell Leukemia/Lymphoma 2) ELISA Kit

SKU:BHE10803086
Overview
Click light‑blue chips for details
Quantitative double-antibody sandwich ELISA kit for measuring rat BCL-2 (B-Cell Leukemia/Lymphoma 2) in Serum, Plasma, Cell Culture Supernatant, and cell or tissue lysate. Includes sensitivity 0.094ng/mL, detection range 0.156–10ng/mL for neuroscience research. Includes assay time 4 hours.
Target BCL-2
Species Rat
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Assay Type Sandwich ELISA, Double Antibody
Sensitivity 0.094ng/ml
Detection Range 0.156-10ng/ml
Assay Time 4 hours
Options selector
Catalog no. Size
ER0762-96T 96 T
Available Options

Select the variant options shown for this product and review lead time and shipping expectations before ordering.

  • Size: 96 tests (96T) kit.
  • Lead time: options listed as “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: 2-8 °C for 12 months; ships cold (typically with ice packs) is expected.
  • Please ensure someone is available to receive and store the shipment promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No ER0762
Alternative Names Apoptosis regulator Bcl-2|BCL2
Assay Time
  • 4 hours
Detection Method
  • Sandwich ELISA
  • Double Antibody
Detection Range 0.156-10ng/ml
Product Type
  • ELISA Kits
Reactivity
  • Rat
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Sensitivity 0.094ng/ml
Species Rat
Storage 2-8 °C for 12 months
Target BCL-2
UniProt # P49950

Background

rat BCL-2 (B-Cell Leukemia/Lymphoma 2) is a molecular target commonly studied in neuroscience, cancer, and immunology research. Many proteins are studied as molecular readouts that can change with cellular state, tissue remodeling, or stress responses.

Biological role and mechanism

The biological role of BCL-2 is typically understood in terms of its molecular category and interaction network. Depending on the model system, it may participate in cell–cell communication, intracellular signaling, enzymatic processing, or regulation of gene expression programs. Mechanistic interpretation is often strengthened by considering upstream regulators and downstream readouts rather than relying on a single marker.

Expression and abundance of BCL-2 can vary by tissue, cell type, and physiological state. In many systems, levels are influenced by factors such as developmental stage, immune activation, metabolic status, and cellular stress. Because sample matrix and pre-analytical handling can affect measured concentrations, interpretation is typically strongest when experiments keep collection and processing consistent across groups.

Nomenclature and related terms

BCL-2 (B-Cell Leukemia/Lymphoma 2) may also be referenced as Apoptosis regulator Bcl-2 and BCL2 in the literature or in databases. When comparing results across studies, confirm that the reported analyte refers to the same molecule, species context, and molecular form (e.g., precursor vs mature protein, or soluble vs membrane-associated forms).

Why it matters in research

  • Understanding how BCL-2 relates to neuronal signaling and synaptic function, neuroinflammation, neurodegeneration models, and brain–body communication in neuroscience, cancer, and immunology research.
  • Interpreting shifts in BCL-2 levels alongside other pathway components or complementary markers.
  • Connecting molecular changes to phenotypes such as inflammation, remodeling, metabolism shifts, or cell-state transitions (context-dependent).

Molecular forms and interpretation

For some targets, isoforms, proteolytic processing, or post-translational modifications (such as phosphorylation or glycosylation) can influence function and apparent abundance. If multiple molecular forms are expected in your model, align interpretation with the form most relevant to the biological question.

Disease and translational relevance

BCL-2 has been investigated across diverse physiological and disease contexts, and changes in its abundance have been reported in areas aligned with neuroscience, cancer, and immunology studies. These associations are interpreted as research findings rather than diagnostic or therapeutic claims, and they should be evaluated alongside model-specific covariates and study design.

?What?s the plate size in FineTest? ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
?How about the shelf life and stability of FineTest? ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest? ELISA Kits have been subject to strict quality test.
?Which cloned antibodies for FineTest? ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
?Can I mix reagents from different batches of FineTest? ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
?Can FineTest? ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
?How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
?Can standard curve be extended to any direction?
FineTest? can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
?Why does detection for serum/plasma sample by FineTest? ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
?What?s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest? can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
?What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

AMPK/mTOR-driven autophagy & Nrf2/HO-1 cascade modulation by amentoflavone ameliorates indomethacin-induced? gastric? ulcer

IF: 6.529 Journal: Biomedicine & Pharmacotherapy Cited Date: 2022-06-02

The potential ameliorating effect of vitamin E on bleomycin? induced lung fibrosis in adult albino rats

IF: 5.6 Journal: International Immunopharmacology Author: Department of Human Anatomy and Embryology, Faculty of Medicine, Alexandria University, Dr Fahmi Abdelmeguid St., Mowassah Campus, Alexandria 21561, Egypt. Cited Date: 2024-06-07

The protective effect of Saudi Arabian bee honey against excessive weight gain and obesity-related parameters in rats fed a high-fat diet

IF: 5.1 Journal: Frontiers in Nutrition Author: Department of Food Sciences and Nutrition, College of Food and Agricultural Sciences, King Saud University, Riyadh, Saudi Arabia. Cited Date: 2025-09-05

Oxidative Damage of Blood Platelets Correlates with the Degree of Psychophysical Disability in Secondary Progressive Multiple Sclerosis

IF: 5.076 Journal: Oxidative Medicine and Cellular Longevity Cited Date: 2020-07-17

Cinnamic Acid: A Shield Against High-Fat-Diet-Induced Liver Injury—Exploring Nrf2's Protective Mechanisms

IF: 4.9 Journal: International Journal of Molecular Sciences Author: Department of Food Science and Nutrition, College of Food and Agricultural Sciences, King Saud University, Riyadh 11451, Saudi Arabia. Cited Date: 2025-10-17

The Role of the SLC1A5 Transporter on Glutathione Homeostasis and Enterocyte Apoptosis in Chronic Treatment of Rats with Immunosuppressive Drugs

IF: 4.9 Journal: International Journal of Molecular Sciences Author: Department of Plastic, Endocrine and General Surgery, Pomeranian Medical University, 72-010 Szczecin, Poland. Cited Date: 2025-10-11

Policosanol ameliorates Post‐Myocardial Infarction-Induced neuronal damage and cognitive impairment in rats via suppressing miRNA-1

IF: 4.9 Journal: The Journal of Nutritional Biochemistry Author: Biochemistry Department, Faculty of Pharmacy, Zagazig University, Zagazig, 44519, Egypt. Cited Date: 2025-08-08

Zhumeria majdae essential oil attenuates TNBS-induced colitis in rats by regulating inflammatory and apoptotic pathways

IF: 4.6 Journal: Infl

Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today