Quantitative double-antibody sandwich ELISA kit for measuring rat Prlr (Prolactin receptor) in Serum, Plasma, Cell Culture Supernatant, and cell or tissue lysate. Includes sensitivity 9.375pg/mL, detection range 15.625–1000pg/mL. Includes assay time 4 hours. Supports quantitative comparison across sample groups.
Target Prolactin receptor
Species Rat
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Assay Type Sandwich ELISA, Double Antibody
Sensitivity 9.375pg/ml
Detection Range 15.625-1000pg/ml
Assay Time 4 hours
Options selector
Catalog no. Size
ER7070-96T 96 T
Available Options

Select the variant options shown for this product and review lead time and shipping expectations before ordering.

  • Size: 96 tests (96T) kit.
  • Lead time: options listed as “in stock at manufacturer” typically ship in 5–7 business days.
  • Storage: 2-8 °C for 12 months; ships cold (typically with ice packs) is expected.
  • Please ensure someone is available to receive and store the shipment promptly.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No ER7070
Alternative Names Prolactin receptor|PRL-R|PRLR|Lactogen receptor
Assay Time
  • 4 hours
Detection Method
  • Sandwich ELISA
  • Double Antibody
Detection Range 15.625-1000pg/ml
Product Type
  • ELISA Kits
Reactivity
  • Rat
Sample Type(s) Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
Sensitivity 9.375pg/ml
Species Rat
Storage 2-8 °C for 12 months
Target Prolactin receptor
UniProt # P05710

Background

rat Prlr (Prolactin receptor) (PRL) is a molecular target commonly studied in biomedical research. Receptors translate extracellular cues into intracellular signaling programs and may be regulated through expression, ligand binding, shedding, and endocytosis.

Biological role and mechanism

The biological role of Prlr is typically understood in terms of its molecular category and interaction network. Depending on the model system, it may participate in cell–cell communication, intracellular signaling, enzymatic processing, or regulation of gene expression programs. Mechanistic interpretation is often strengthened by considering upstream regulators and downstream readouts rather than relying on a single marker.

Expression and abundance of Prlr can vary by tissue, cell type, and physiological state. In many systems, levels are influenced by factors such as developmental stage, immune activation, metabolic status, and cellular stress. Because sample matrix and pre-analytical handling can affect measured concentrations, interpretation is typically strongest when experiments keep collection and processing consistent across groups.

Nomenclature and related terms

Prlr (Prolactin receptor) (PRL) may also be referenced as Prolactin receptor, PRL-R, and PRLR in the literature or in databases. When comparing results across studies, confirm that the reported analyte refers to the same molecule, species context, and molecular form (e.g., precursor vs mature protein, or soluble vs membrane-associated forms).

Why it matters in research

  • Understanding how Prlr relates to signal transduction, tissue homeostasis, stress responses, and disease-model biology in biomedical research.
  • Interpreting shifts in Prlr levels alongside other pathway components or complementary markers.
  • Connecting molecular changes to phenotypes such as inflammation, remodeling, metabolism shifts, or cell-state transitions (context-dependent).

Molecular forms and interpretation

For some targets, isoforms, proteolytic processing, or post-translational modifications (such as phosphorylation or glycosylation) can influence function and apparent abundance. If multiple molecular forms are expected in your model, align interpretation with the form most relevant to the biological question.

Disease and translational relevance

Prlr has been investigated across diverse physiological and disease contexts, and changes in its abundance have been reported in areas aligned with biomedical studies. These associations are interpreted as research findings rather than diagnostic or therapeutic claims, and they should be evaluated alongside model-specific covariates and study design.

?What?s the plate size in FineTest? ELISA Kits?
The ELISA plate follows the standard size of microplate: 127.64 mm x 85.60 mm x 14.22 mm(L x W x H).
?How about the shelf life and stability of FineTest? ELISA Kits?
Valid for 12 months since the production date. For the shelf life of specific batch number, please check the label printed on the kit. Before delivery, all FineTest? ELISA Kits have been subject to strict quality test.
?Which cloned antibodies for FineTest? ELISA Kits are used?
These information is proprietary. Please contact us to learn more about clonality (polyclonality or monoclonality) and host species.
?Can I mix reagents from different batches of FineTest? ELISA Kits?
Not suggested. ELISA reagents are optimized for specific batch.
?Can FineTest? ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
?How long can the diluted lyophilized standard be stored for continual use?
Used up within 12h.
?Can standard curve be extended to any direction?
FineTest? can't support validation of standard concentration outside of standard curve. Ranges of standard curve have been validated among many batches and experimenters, showing stable and accurate performance. The lowest standard concentration is the minimized range for reliable detection results. Adding higher or lower concentration of standard may cause inconsistent signal or false positive.
?Why does detection for serum/plasma sample by FineTest? ELISA Kits require for 1/2 dilution?
Matrix components in serum/plasma can affect detection results. Blocking components in sample dilution buffer can decrease or remove the interference. The dilution can reduce the matrix difference between sample and standard to get better accuracy.
?What?s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest? can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.
?What's the expected concentration for particularly analyzing my sample?
Due to the specificity of each sample, it's hard to forecast and depend on sample preparation as well as analytical characteristics. Please contact us to get detection data for reference.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Hematological changes, oxidative stress assessment, and dysregulation of aquaporin-3 channel, prolactin, and oxytocin receptors in kidneys of lactating Wistar rats treated with monosodium glutamate

IF: 3.6 Journal: Naunyn-Schmiedeberg's Archives of Pharmacology Author: Department of Human Physiology, Faculty of Basic Medical Sciences, College of Medical Sciences, Ahmadu Bello University, Zaria, Kaduna, Nigeria. Cited Date: 2024-03-15

Evaluation of Metoclopramide Hydrochloride-Induced Alterations in Prolactin Receptor Expression, Aquaporin-3, Oxytocin Receptors, and Other Key Biomarkers in the Mammary Glands of Lactating Wistar Rats

IF: 1.024 Journal: EC Pharmacology and Toxicology Author: Department of Human Physiology, College of Medical Sciences, Faculty of Basic Medical Sciences, Ahmadu Bello University, Zaria, Kaduna, Nigeria Cited Date: 2025-02-28

Preliminary monosodium glutamate-induced changes in mammary gland receptors and gene expression, water channel, oxidative stress, and some lactogenic biomarkers in lactating rats

IF: 0.9 Journal: The Journal of Basic and Applied Zoology Author: Department of Human Physiology, College of Medical Sciences, Faculty of Basic Medical Sciences, Ahmadu Bello University, Zaria, Kaduna, Nigeria Cited Date: 2024-02-18

Can FineTest® ELISA Kits be used partially?
Yes. The ELISA plate is dismounted. Enough component volumes are offered by 96T ELISA kit, supporting two groups of standard curve.
What’s the half-life of protein in serum/plasma/cell culture supernatant?
FineTest® can't determine the half-life of protein in the sample(e.g. serum, plasma or cell culture supernatant). Usually, it's suggested to detect prepared sample immediately or aliquot sample to refrigerate in a disposable container. Avoid freeze-thaw cycle to prevent protein degradation.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today