Streptavidin Plates

SKU:BHU14200009
Overview
Click light‑blue chips for details
Streptavidin-coated microplate for oriented biotinylated ligand capture in ELISA.
Surface Streptavidin
Plate Format Breakable · Strip · Solid
Well Volume 350 µl, 360 µl, 400 µl
Material Polystyrene
Binding Capacity Biotin = ~ 12 – 14 pmol/well (200 μl), IgG-b = 100 ng/ well
Uniformity CV < 5 %
Blocking Standard · Non-Proteic
Available Options

Configure Your Order

Color
Clear: Recommended for colorimetric/UV readout (450 nm). Transparent bottom allows transmitted-light imaging.
White: Maximises reflectance — preferred for luminescence assays (LIA, CLIA).
Black: Minimises optical background — preferred for fluorescence assays (FIA).
Plate Format
Breakable Strips (350 µl/well): 12 individual breakable strips of 8 wells — ideal for testing variable sample numbers or running assays in multiple batches.
Strip Frame (360 µl/well): Strips on a rigid 12×8 frame that prevent misorientation — recommended for automation-assisted liquid handling and plate washers.
Solid Plate (400 µl/well): Standard solid 96-well plate — preferred for high-throughput uniform assays and large sample batches.
Blocking
Standard (Proteic): BSA-based blocking — suitable for the majority of ELISA, LIA, FIA, and CLIA assay formats.
Non-Proteic (BlockerWell): Protein-free blocking — essential when BSA or animal-derived proteins would generate background or interfere with analyte detection (e.g., total protein assays, anti-BSA antibody panels).
Order Details
Minimum order: 10 pcs. Unit: 5 pcs per unit. Storage: 2 – 8 °C. Each plate is packaged in an individual sealed barrier bag with desiccant to ensure stability until first use.
Options selector
Catalog no. Color & Well Volume Blocking Packaging
MG0STF-SA5/200 Clear & 350 µl (Breakable Strip)
MGW0STF-SA5/200 White & 350 µl (Breakable Strip)
MGB0STF2-SA5/200 Black & 350 µl (Breakable Strip)
MT0STF4-SA5/200 Clear & 360 µl (Strip Frame)
MTW0STF4-SA5/200 White & 360 µl (Strip Frame)
MTB0STF4-SA5/200 Black & 360 µl (Strip Frame)
MC0STF-SA5/200 Clear & 400 µl (Solid Plate)
MCW0STF-SA5/200 White & 400 µl (Solid Plate)
MCB0STF-SA5/200 Black & 400 µl (Solid Plate)
Field Specification
Product Type
  • Coated Microplate

The Streptavidin Plates are ideal for binding a wide range of biotinylated molecules, making them highly recommended for ELISA and other immunoassays. Streptavidin is one of the most popular biotin-binding proteins in research, with each of its four subunits capable of binding a biotin molecule, resulting in enhanced assay sensitivity and reliability. The streptavidin-coated surface provides a versatile and powerful platform for capturing biotinylated antibodies, antigens, proteins, peptides, polysaccharides, oligonucleotides, DNA fragments, and more. This coating is especially useful for molecules that may not adhere reliably through passive adsorption or that require specific orientation f

Streptavidin Coated Plates are pre-blocked in order to minimize any non-specific binding and to ensure long-term stability.

Key Features

  • Streptavidin-coated surface: Versatile platform for capturing a wide range of biotinylated molecules, including antibodies, antigens, proteins, peptides, polysaccharides, oligonucleotides, and DNA fragments.Ideal for binding molecules that: do not adhere reliably through passive adsorption require specific orientation for optimal binding.
    • do not adhere reliably through passive adsorption
    • require specific orientation for optimal binding.
  • Blocking: Plates are pre blocked with standard proteic blocking (ELISA Blocking) or with non proteic blocking (BlockerWell)
  • Low Fluorescence Polystyrene: Manufactured with pure high-quality polystyrene, minimizing background noise and improving optical clarity.
  • Wells design: flat bottom.
  • Multiple Formats: Available in breakable strip plates, non-breakable strip plates, and solid plates for flexibility in applications.
  • Colors: Available in clear, white, and black. Customizable upper rim colors upon request. Reduced Crosstalk: White and black plates minimize well-to-well light scatter, improving signal accuracy in luminescence and fluorescence assays. Uniform Optical Properties: Clear plates are ideal for spectrophotometric readings and imaging, providing consistent and accurate light transmission.
    • Reduced Crosstalk: White and black plates minimize well-to-well light scatter, improving signal accuracy in luminescence and fluorescence assays.
    • Uniform Optical Properties: Clear plates are ideal for spectrophotometric readings and imaging, providing consistent and accurate light transmission.
  • Automation-Compatible: Easily integrated with high-throughput automated systems for liquid handling, washing, and analysis.
  • Alphanumeric Coding: For easy and accurate well identification during experiments.
  • Recommended working volume: of 75 to 200 μl
  • Packaging: Each coated plate is packed in a single barrier bag with desiccant
  • Unit: Contains 5 plates
  • Minimum order: 10 plates.
  • Ready to use

Key Benefits

  • Plates Design: The mould design provides optical quality, important to reduce the background signal. The rim protects the external face of the bottom from scratches
    • The mould design provides optical quality, important to reduce the background signal.
    • The rim protects the external face of the bottom from scratches
  • Improved Washing Efficiency: Radius-edged well bottoms enhance washing, reducing residual materials and improving assay consistency.
  • Reduced Cross-Contamination: Designed to minimize the risk of cross-contamination between wells, ensuring precise sample isolation.
  • Enhanced Imaging: The flat surface provides a clear focal plane, essential for high-quality imaging in microscopy, especially for fluorescence and phase-contrast analysis.
  • Improved Mixing: The flat-bottom design facilitates better sample mixing, ensuring consistent results across assays.

Applications

  • Specific and sterically oriented bond of antibodies
  • Purification and detection of mouse monoclonal IgG antibodies and for purification of macaque IgG
  • Highest specificity and capacity
  • Retains antibody activity and orients antibody for maximum binding
  • ELISA Assays: For competitive and sandwich ELISA, detecting a wide range of targets such as steroid hormones and antibodies.
  • Luminescence Assays (LIA): Optimized for high-sensitivity luminescence detection.
  • Fluorescence Assays (FIA): Ensures strong signal detection with minimal interference.
  • Chemiluminescent Assays (CLIA): Ideal for highly sensitive and quantitative analyses.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Supplier Ads Slides show

Add dynamic ads with slider