Tavolimab ELISA Kit

SKU:BHE21400269
Overview
Click light‑blue chips for details
Competitive ELISA kit for quantitative measurement of tavolimab in serum, plasma and other biological fluid samples. Pre-coated 96-well plate with colorimetric readout at 450 nm; detection range 31.25 - 2,000 ng/mL, sensitivity 6.32 ng/mL. For research use only.
Assay Type Competitive (Quantitative)
Sample Type Serum, Plasma, Other Fluids
Detection Range 31.25 - 2,000 ng/mL
Sensitivity 6.32 ng/mL
Options selector
Catalog no. Size
DW342038-96T 96 T
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 96 T
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
  • Shipping: 2-8 °C
  • Upon receipt: for longer storage of unopened kits, keep the microplate, standard and detection reagents at -20 °C and the other reagents at 4 °C (see the datasheet).
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Target Tavolimab
Alternative names Tavolixizumab | MEDI0562 | 1635395-25-3
Reactivity
  • Human
Applications
  • ELISA
Assay type
  • Competitive (Quantitative)
Sample type(s) Serum | Plasma | Other Biological Fluid Samples
Sensitivity 6.32 ng/mL
Detection range 31.25 - 2,000 ng/mL
Detection method
  • Colorimetric
Storage The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% prior to the expiration date under appropriate storage condition.
Shipping 2-8 ℃
Catalog no. (Mfr.) DW342038
Main SKU BHE21400269

Product Overview

The Tavolimab ELISA Kit is a competitive ELISA kit for quantitative measurement of tavolimab in serum, plasma and other biological fluid samples. The 96-well microplate is pre-coated, and the colorimetric signal is read at 450 nm.

In this competitive format, tavolimab in standards and samples competes for a limited number of binding sites in the pre-coated wells, so the optical density falls as the tavolimab concentration rises. Concentrations are calculated from the standard curve run on the same plate.

Specifications

Alternative Names Tavolixizumab; MEDI0562; 1635395-25-3
Assay Type Competitive (Quantitative)
Detection Method Colorimetric (OD 450 nm)
Sample Type Serum, Plasma, Other Biological Fluid Samples
Sensitivity 6.32 ng/mL
Detection Range 31.25 - 2,000 ng/mL
Recovery 80-120%
Precision Intra-assay CV <15%; Inter-assay CV <15%
Kit Size 96 T
Shipping 2-8 °C

Kit Components

Component Quantity Storage
Pre-coated Microplate 1 plate -20 °C
Tavolimab Standard 2 bottles -20 °C
Detection A 1 vial -20 °C
Detection B 1 vial -20 °C
Standard Diluent 1 bottle 4 °C
Assay Diluent 1 bottle 4 °C
20× Wash Buffer 1 bottle 4 °C
Color Reagent 1 bottle 4 °C
Stop Solution 1 bottle 4 °C
Plate Sealers 4 strips Room temperature

Assay Procedure (Summary)

Bring all reagents to room temperature and prepare working solutions and the standard series before starting.

  1. Add 100 µL standard or sample premixed with Detection A working solution (50 µL + 50 µL); incubate 1 h at 37 °C.
  2. Wash 3 times with 300 µL wash buffer per well.
  3. Add 100 µL Detection B working solution; incubate 30 min at 37 °C.
  4. Wash 5 times with 300 µL wash buffer per well.
  5. Add 100 µL Color Reagent; incubate 15 min at 37 °C, protected from light.
  6. Add 50 µL stop solution; the color turns from blue to yellow.
  7. Read the OD at 450 nm within 10 min (wavelength correction at 630 nm or 620 nm).

Total incubation time is about 1 h 45 min, plus washing steps. Required but not supplied: a microplate reader for 450 nm (correction at 630 nm or 620 nm), pipettes and tips, deionized or distilled water, a 500 mL graduated cylinder, a squirt bottle, manifold dispenser or plate washer, and tubes for standard dilutions.

Sample Preparation

  • Serum: use a serum separator tube, let the sample clot for 30 minutes at room temperature, and centrifuge for 15 minutes at 1000 × g.
  • Plasma: collect with EDTA, heparin or citrate as the anticoagulant and centrifuge for 15 minutes at 1000 × g within 30 minutes of collection.
  • Assay samples promptly or store aliquots at -20 °C or below; avoid repeated freeze-thaw cycles.
  • Serum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve.

Storage & Handling

Ships at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use and do not mix components from different kit lots.

For Research Use Only. Not for use in diagnostic procedures.

Q.Which sample types can be tested?
A.The kit is intended for serum, plasma and other biological fluid samples. Serum and plasma samples: a 10-fold starting dilution in Standard Diluent is suggested; adjust it so readings fall within the standard curve. Validate dilution and recovery before running a new matrix.
Q.What are the detection range and sensitivity?
A.The detection range is 31.25 - 2,000 ng/mL and the sensitivity is 6.32 ng/mL. Lot-specific values are also reported on the Certificate of Analysis supplied with each kit. Dilute samples so readings fall within the standard curve.
Q.How long does the assay take?
A.Incubations total about 1 h 45 min at 37 °C, plus washing, reagent preparation and plate reading. A microplate reader at 450 nm is required, with correction at 630 nm or 620 nm if available.
Q.Can the plate be used partially?
A.Yes. Unused strips can be removed from the frame, returned to the foil pouch with the desiccant and resealed for later use.
Q.How should the kit be stored?
A.Ships at 2-8 °C. For longer storage of unopened kits, keep the pre-coated microplate, standard, Detection A and Detection B at -20 °C and the other liquid reagents at 4 °C. Bring reagents to room temperature before use.
Q.Is this kit for diagnostic use?
A.No. This product is for research use only and is not intended for diagnostic or therapeutic procedures.

Can’t Find What You’re Looking For? We can help you source the best match or customize an ELISA solution for your study. Options may include alternative target synonyms, different species reactivity, sample type/matrix compatibility (serum/plasma/lysate/supernatant), assay format (sandwich/competitive), sensitivity/range, detection chemistry (colorimetric/fluorescent/chemiluminescent), plate format (pre-coated/uncoated, strips vs full plate), and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today