Triglyceride Colorimetric Assay Kit

SKU:BHT19600060
Overview
Click light‑blue chips for details
Triglycerides are the principal storage form of fatty acids. This kit quantifies Triglyceride by absorbance at OD 570 nm. Suitable for serum, plasma, cell culture, tissues, other biological samples. Colorimetric detection is sufficient for serum and tissue triglyceride, where concentrations are high.
Assay Type Colorimetric
Detection Wavelength OD 570 nm
Assay Time 30-60 minutes
Sample Type Serum, Plasma, Cell Culture, Tissue
Detection Range as low as 1 mg/dL
Storage -20°C
Options selector
Catalog no. Size
TBS2205C 100 tests
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 100 tests
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: Store kit at -20°C. Shelf life of 12 months.
  • Shipping: -20°C
  • Upon receipt: store at recommended temperature as soon as possible.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Applications
  • Metabolic Assay
Assay type
  • Colorimetric
Sample type(s) Serum, Plasma, Cell Culture, Tissue
Detection range as low as 1 mg/dL
Detection method
  • Absorbance
Detection wavelength OD 570 nm
Assay time
  • 30-40 minutes
Storage Store kit at -20°C. Shelf life of 12 months.
Shipping -20°C
Catalog no. (Mfr.) TBS2205C
Main SKU BHT19600060
Metabolite Assay Kit

About the Analyte

Triglycerides are the principal storage form of fatty acids, and their concentration in serum or tissue is central to research on obesity, insulin resistance and hepatic steatosis.

Assay Principle

The Triglyceride Colorimetric Assay Kit applies a colorimetric format to this measurement, read at OD 570 nm. Hands-on and incubation time is 30-40 minutes.

The glycerol is oxidized to generate hydrogen peroxide which reacts with the probe measured by colorimetric method at OD = 570 nm.

Colorimetric detection is sufficient for serum and tissue triglyceride, where concentrations are high.

Specifications

Assay Type Colorimetric
Detection Method Absorbance
Detection Wavelength OD 570 nm
Detection Range as low as 1 mg/dL
Assay Time 30-40 minutes
Sample Types serum, plasma, cell culture, tissues, other biological samples
Size 100 tests
Storage Store kit at -20°C. Shelf life of 12 months.
Shipping -20°C

Applications

  • Metabolic Assay

Storage & Handling

Store kit at -20°C. Shelf life of 12 months.

Safety

For research use only. Not for use in diagnostic or therapeutic procedures. Handle in accordance with good laboratory practice; consult the SDS before use.

Q.What instrument do I need to quantify this analyte?
A.This kit requires a standard absorbance plate reader. The readout is taken at OD 570 nm.
Q.What does the measured level tell me?
A.Colorimetric detection is sufficient for serum and tissue triglyceride, where concentrations are high.
Q.Why measure Triglyceride?
A.Triglycerides are the principal storage form of fatty acids, and their concentration in serum or tissue is central to research on obesity, insulin resistance and hepatic steatosis.
Q.Which sample matrices are validated?
A.The datasheet lists serum, plasma, cell culture, tissues, other biological samples. Other matrices can usually be adapted, but run a spike-recovery check before relying on the values.
Q.How long does the quantitation take?
A.Combined incubation and handling time is 30-40 minutes. Keep this interval identical across plates in the same study, since timing differences show up directly in the endpoint.
Q.What is the detection range?
A.The kit is validated for as low as 1 mg/dL under datasheet conditions. Dilute samples that read above the range and concentrate those below it rather than extrapolating from the standard curve.

Customization & Add-ons: Need this assay kit tailored to your workflow? We can help with bulk or custom pack sizes, additional substrate, standards or positive controls, alternate plate formats (96- or 384-well, strip-well), automation-ready reagent fills for liquid-handling workstations, and custom assay development for enzymes and analytes not in our catalog. Click Talk to a Scientist to submit a request, email us at support@biohippo.com, or explore our Research Services — our team will follow up with feasibility details and next steps.

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today