Vero Cell Host Cell Protein ELISA Kit

SKU:BHE19600042
Overview
Click light‑blue chips for details
For accurate Vero Cell Host Cell Protein quantification, the Vero Cell Host Cell Protein ELISA Kit pairs a sandwich ELISA workflow with a pre-coated microplate, target standard, and detection reagents. Validated biological samples matrices give dependable standard-curve readouts, with a lower detection limit near 1.1 ng/mL, a working range of 1–200 ng/mL, and a typical run time of 2 hours.
Assay Type Solid-phase ELISA
Sensitivity 1.1 ng/mL
Detection Range 1–200 ng/mL
Assay Time 2 hours
Plate Format 96-well microplate
Options selector
Catalog no. Size
TBS31005 1 x 96-well plate
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: Size: 1 x 96-well plate
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: Store the unopened kit at 2-8 ℃.
  • Shipping: cold-chain shipment (typically with ice packs).
  • Upon receipt: refrigerate upon receipt.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Mfr No TBS31005
Assay Time
  • 2 hours
Detection Range 1–200 ng/mL
Product Type
  • ELISA Kits
  • Sandwich ELISA Kit
Sensitivity 1.1 ng/mL
Storage Store the unopened kit at 2-8°C.
Target Vero Cell Host Cell Protein
ELISA Kit

Assay Principle

The Tribioscience Vero cell HCP Fast ELISA is designed to quantitatively detect Vero cell HCP residues in different biological samples. The main feature is that the kit uses our novel proprietary approaches to combine samples and detections into a one-step instead of the complicated traditional methods. It makes the assay flexible, accurate, simple, and time saving. The measurement can be finished in 2 hours, not needing 4-5 hours (Fig. 1). The detection range is from 1 to 200 ng/mL. The levels of Vero HCP samples are parallel to the standard curves obtained using the kit standards linearly. These results indicate that this kit can be used to determine relative mass values for Vero host cell protein.

Typical Data This standard curve is provided for demonstration only. A standard curve should be generated for each set of samples assayed. Fig. 3 is an example of typical Data.

The Intra-assay CV is 3.79% and the Inter-assay CV is ˂10%.

Vero Cell Host Cell Protein ELISA Kit is a Solid-phase ELISA for the quantitative determination of Vero Cell Host Cell Protein. The microplate is pre-coated with a capture antibody specific to the target. Target present in the sample or standard binds the immobilized antibody, is detected with a biotinylated detection antibody and streptavidin-HRP, and quantified colorimetrically against a standard curve.

Kit Components

The kit provides a pre-coated microplate, target standard for standard-curve generation, detection reagents (detection antibody and enzyme conjugate), wash buffer, substrate, and stop solution. Refer to the product datasheet for the complete component list and quantities.

Performance Data

Target Vero Cell Host Cell Protein
Test Principle Solid-phase ELISA
Sensitivity 1.1 ng/mL
Detection Range 1–200 ng/mL
Assay Time 2 hours
Precision Intra-assay CV 3.79%; Inter-assay CV 10%
Specificity This assay recognizes Vero HCP.
Storage Store the unopened kit at 2-8°C.

✓ Quality tested for reproducibility and lot-to-lot consistency

Safety & Handling

For Research Use Only (RUO). Not for use in diagnostic or therapeutic procedures. Follow standard laboratory safety practices and consult the SDS before handling.
What is the sensitivity and detection range?

This assay has a sensitivity of 1.1 ng/mL and a detection range of 1–200 ng/mL. Samples reading outside the range should be diluted or concentrated.

How long does the assay take?

The total assay time is approximately 2 hours from sample addition to plate reading.

What is included in the kit?

The kit provides a pre-coated microplate, target standard for standard-curve generation, detection reagents (detection antibody and enzyme conjugate), wash buffer, substrate, and stop solution. See the datasheet for the full component list and quantities.

What instrument is required?

A standard microplate reader capable of measuring absorbance at 450 nm is required for this sandwich ELISA.

Customization & Add-ons: Need this ELISA kit tailored to your workflow? We can help with bulk or custom pack sizes, species or analyte variants, matched antibody pairs and standards, alternate plate formats (48- or 96-well, strip-well), and assay development or custom ELISA solutions for targets not in our catalog. Click Talk to a Scientist to submit a request, email us at support@biohippo.com, or explore our Research Services — our team will follow up with feasibility details and next steps.

Matches this product
$50 OFF
$50 Off All ELISA Kits
Limited time ELISA50
15%OFF
15% Off Cancer Antibodies
Ends Sep 30 ONCO15
10% OFF
10% OFF CELL LINES-Limited-Time Offer
Ends Sep 30 CELL10
FREE SAMPLE
Free Sample – CellTrypase Recombinant Trypsin-Like Enzyme
Limited time offer – availa... FREESAMPLE
FREE SAMPLE
Free Sample – MycoFold™ Growth Factors
Limited time offer – availa... Request Free Sample

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today