GenJet™ In Vitro DNA Transfection Reagent for CV-1 Cells

SKU:BHT2200013
Research Validated
Overview
Click light‑blue chips for details
GenJet™ In Vitro DNA Transfection Reagent for CV-1 Cells is a SignaGen Laboratories reagent pre-optimized for plasmid DNA delivery into CV-1 cells, so the usual optimization step is not needed. CV-1, a fibroblast-like line, was established in 1964 from the kidney of an adult African green monkey (Chlorocebus aethiops, formerly Cercopithecus aethiops).
Transfection Type DNA Transfection
Application Setting In Vitro
Optimized Cell Line CV-1
Storage 4 °C
Shelf Life 24 months
Options selector
Catalog no. Size
SL100489-CV1-0P1ML 0.1 mL
SL100489-CV1-0P5ML 0.5 mL
SL100489-CV1-1P0ML 1.0 mL
SL100489-CV1-1P0MLX5 1.0 mL x 5
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: 4 variants available — select size from the variant selector.
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: Store at 4°C. When maintained under the recommended storage conditions, the product remains stable for at least 24 months.
  • Shipping: Please contact us to confirm shipping conditions for this product.
  • Upon receipt: refrigerate upon receipt.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Storage 4 °C
Catalog no. (Mfr.) SL100489-CV1
Main SKU BHT2200013

Product Overview

CV-1, a fibroblast-like line, was established in 1964 from the kidney of an adult African green monkey (Chlorocebus aethiops, formerly Cercopithecus aethiops). Over the decades that followed it became a fixture of virology, molecular biology, and gene expression studies, and it is especially associated with simian virus 40 (SV40) research, with recombinant DNA technology, and with the building of transient gene expression systems. Adherent growth, vigorous proliferation, and ready susceptibility to a variety of viral infections make CV-1 cells a valuable model for studying viral replication, host–pathogen interactions, and transgene expression.

GenJet™ DNA In Vitro Transfection Reagent for CV-1 Cells arrives tuned to this line, moving plasmid DNA into CV-1 cells efficiently.

Specifications

Transfection Type DNA Transfection
Application Setting In Vitro
Pre-Optimized Yes — Pre-Optimized for Specific Cell Type
Optimized Cell Line CV-1
Storage Store at 4°C. When maintained under the recommended storage conditions, the product remains stable for at least 24 months.

Kit Contents

One milliliter of GenJet™ Reagent is sufficient for approximately 300–600 transfections in 24-well plates or 50–100 transfections in 6-well plates, depending on the culture format and amount of DNA used.

Performance Data

GenJet™ In Vitro DNA Transfection Reagent for CV-1 Cells – GFP transfection in CV-1 cells
A representative fluorescence image demonstrating the transfection efficiency of GenJet™ Reagent in CV-1 cells. CV-1 cells were cultured under ATCC-recommended growth conditions and transfected with the pEGFP-N3 reporter plasmid using GenJet™ Reagent. Transfection efficiency was evaluated 24 hours post-transfection by monitoring GFP expression.

Applications

This DNA transfection reagent supports a range of molecular biology applications including transient and stable transfection, reporter assays, protein expression studies, and gene function analysis in mammalian cell systems.

Safety & Handling

For Research Use Only (RUO) — Not for diagnostic or therapeutic use. Handle reagents according to institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for detailed handling and disposal instructions.
Q.What cell types are compatible with GenJet™ In Vitro DNA Transfection Reagent for CV-1 Cells?
A.This reagent is designed for broad compatibility with mammalian cell lines. It is pre-optimized for CV-1 cells for maximum efficiency. SignaGen offers pre-optimized versions for specific cell types.
Q.How should I store GenJet™ In Vitro DNA Transfection Reagent for CV-1 Cells?
A.Store at 4°C. When maintained under the recommended storage conditions, the product remains stable for at least 24 months. Follow the product datasheet for detailed storage and stability information.
Q.Do I need to optimize transfection conditions with this product?
A.No. GenJet™ In Vitro DNA Transfection Reagent for CV-1 Cells is pre-optimized for CV-1 cells, so optimization is not required. Follow the provided protocol for best results.
Q.How many transfections does one vial provide?
A.One milliliter of GenJet™ Reagent is sufficient for approximately 300–600 transfections in 24-well plates or 50–100 transfections in 6-well plates, depending on the culture format and amount of DNA used. Actual numbers depend on plate format and the amount of nucleic acid used.
Q.What are CV-1 cells?
A.CV-1, a fibroblast-like line, was established in 1964 from the kidney of an adult African green monkey (Chlorocebus aethiops, formerly Cercopithecus aethiops). Over the decades that followed it became a fixture of virology, molecular biology, and gene expression studies, and it is especially associated with simian virus 40 (SV40) research, with recombinant DNA technology, and with the building of transient gene expression systems.
Q.Is this product suitable for diagnostic or therapeutic use?
A.No. This product is for Research Use Only (RUO) and is not intended for diagnostic, therapeutic, or clinical applications.

Can't Find What You're Looking For? We can help you source the best match or customize a transfection solution for your study. Options may include pre-optimized formulations for a cell line not listed here, matching transfection buffer supplied with the reagent, DNA, siRNA or in vivo formats within the same reagent family, and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Du J, Liao W, Wang H, et al.. MDIG-mediated H3K9me3 demethylation upregulates Myc by activating OTX2 and facilitates liver regeneration. Signal Transduct Target Ther (2023) 8(1), 351-351.. 10.1038/s41392-023-01575-5

Zhang X, McGinnis C, Yu G, et al.. Erythropoietin receptor on cDC1s dictates immune tolerance. Nature (2025). 10.1038/s41586-025-09824-z

Lee M, Siddoway B, Kaeser G, et al.. Somatic APP gene recombination in Alzheimer's disease and normal neurons. Nature (2018) 563(7733), 639-645.. 10.1038/s41586-018-0718-6

Konermann S, Brigham M, Trevino A, et al.. Optical control of mammalian endogenous transcription and epigenetic states. Nature (2013) 500(7463), 472-476.. 10.1038/nature12466

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today