GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells

SKU:BHT2200018
Research Validated
Overview
Click light‑blue chips for details
GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells is a SignaGen Laboratories reagent pre-optimized for plasmid DNA delivery into HuH-7 cells, so the usual optimization step is not needed. HuH-7, a human hepatocellular carcinoma line, turns up often in liver biology, virology, and gene expression studies. One milliliter of GenJet™ reagent is sufficient for approximately 300–600 transfections in 24-well plates or 150–300 transfections in 6-well plates.
Transfection Type DNA Transfection
Application Setting In Vitro
Optimized Cell Line HuH-7
Storage 4 °C
Shelf Life 24 months
Options selector
Catalog no. Size
SL100489-HUH-0P1ML 0.1 mL
SL100489-HUH-0P5ML 0.5 mL
SL100489-HUH-1P0ML 1.0 mL
SL100489-HUH-1P0MLX5 1.0 mL x 5
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: 4 variants available — select size from the variant selector.
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: Store at 4°C. When maintained under recommended storage conditions, the reagent remains stable for at least 24 months.
  • Shipping: Please contact us to confirm shipping conditions for this product.
  • Upon receipt: refrigerate upon receipt.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Storage 4 °C
Catalog no. (Mfr.) SL100489-HUH
Main SKU BHT2200018

Product Overview

HuH-7, a human hepatocellular carcinoma line, turns up often in liver biology, virology, and gene expression studies. Transfecting it is generally harder than transfecting HEK293-derived cells; proprietary peptide-conjugation technology built into GenJet™ reagent addresses that, driving plasmid DNA in at high efficiency and reaching as much as 70% GFP-positive cells under optimized conditions. GenJet™ DNA In Vitro Transfection Reagent for HuH-7 Cells therefore ships pre-tuned for transfection of human HuH-7 cells.

Specifications

Transfection Type DNA Transfection
Application Setting In Vitro
Pre-Optimized Yes — Pre-Optimized for Specific Cell Type
Optimized Cell Line HuH-7
Storage Store at 4°C. When maintained under recommended storage conditions, the reagent remains stable for at least 24 months.

Kit Contents

One milliliter of GenJet™ reagent is sufficient for approximately 300–600 transfections in 24-well plates or 150–300 transfections in 6-well plates.

Performance Data

GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells – GFP transfection vs L2K and FuGENE® HD; serum/antibiotic effect
GenJet™ reagent is specifically optimized for HuH-7 cells and demonstrates superior transfection performance compared with Lipofectamine™ 2000 (L2K) and FuGENE® HD. HuH-7 cells were cultured according to recommended conditions and transfected with the GFP expression plasmid pEGFP-N3 using GenJet™ reagent. Transfection efficiency was evaluated 48 hours post-transfection. Right Panel: Comparison of transfection efficiency among GenJet™, Lipofectamine™ 2000 (L2K), and FuGENE® HD in HuH-7 cells. Cells were transfected with pEGFP-N3 according to each manufacturer’s recommended protocol. The percentage of GFP-positive cells and relative fluorescence intensity were quantified by flow cytometry (FACS) 48 hours post-transfection. Left Panel: The presence of serum and antibiotics enhances GenJet™-mediated transfection efficiency in HuH-7 cells. HuH-7 cells cultured on collagen-coated dishes were transfected under three different conditions: (1) serum- and antibiotic-free medium; (2) medium containing 10% serum and antibiotics, with medium replacement 5 hours post-transfection; and (3) medium containing 10% serum and antibiotics without medium replacement. Transfection efficiency was assessed 48 hours post-transfection.
GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells – GFP transfection in HuH-7 cells
A representative fluorescence microscopy image demonstrating the transfection efficiency of the pre-optimized GenJet™ Reagent in HuH-7 cells. HuH-7 cells were cultured under recommended growth conditions on collagen type I–coated culture dishes and transfected with the GFP reporter plasmid pEGFP-N3 using GenJet™ Reagent. Transgene expression was assessed 24 hours post-transfection by fluorescence imaging with a Nikon Eclipse 2000 microscope. GFP fluorescence served as an indicator of plasmid DNA delivery and gene expression efficiency.

Applications

This DNA transfection reagent supports a range of molecular biology applications including transient and stable transfection, reporter assays, protein expression studies, and gene function analysis in mammalian cell systems.

Safety & Handling

For Research Use Only (RUO) — Not for diagnostic or therapeutic use. Handle reagents according to institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for detailed handling and disposal instructions.
Q.What cell types are compatible with GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells?
A.This reagent is designed for broad compatibility with mammalian cell lines. It is pre-optimized for HuH-7 cells for maximum efficiency. SignaGen offers pre-optimized versions for specific cell types.
Q.How should I store GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells?
A.Store at 4°C. When maintained under recommended storage conditions, the reagent remains stable for at least 24 months. Follow the product datasheet for detailed storage and stability information.
Q.Do I need to optimize transfection conditions with this product?
A.No. GenJet™ In Vitro DNA Transfection Reagent for HuH-7 Cells is pre-optimized for HuH-7 cells, so optimization is not required. Follow the provided protocol for best results.
Q.How many transfections does one vial provide?
A.One milliliter of GenJet™ reagent is sufficient for approximately 300–600 transfections in 24-well plates or 150–300 transfections in 6-well plates. Actual numbers depend on plate format and the amount of nucleic acid used.
Q.What are HuH-7 cells?
A.HuH-7, a human hepatocellular carcinoma line, turns up often in liver biology, virology, and gene expression studies.
Q.Is this product suitable for diagnostic or therapeutic use?
A.No. This product is for Research Use Only (RUO) and is not intended for diagnostic, therapeutic, or clinical applications.

Can't Find What You're Looking For? We can help you source the best match or customize a transfection solution for your study. Options may include pre-optimized formulations for a cell line not listed here, matching transfection buffer supplied with the reagent, DNA, siRNA or in vivo formats within the same reagent family, and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Du J, Liao W, Wang H, et al.. MDIG-mediated H3K9me3 demethylation upregulates Myc by activating OTX2 and facilitates liver regeneration. Signal Transduct Target Ther (2023) 8(1), 351-351.. 10.1038/s41392-023-01575-5

Zhang X, McGinnis C, Yu G, et al.. Erythropoietin receptor on cDC1s dictates immune tolerance. Nature (2025). 10.1038/s41586-025-09824-z

Lee M, Siddoway B, Kaeser G, et al.. Somatic APP gene recombination in Alzheimer's disease and normal neurons. Nature (2018) 563(7733), 639-645.. 10.1038/s41586-018-0718-6

Konermann S, Brigham M, Trevino A, et al.. Optical control of mammalian endogenous transcription and epigenetic states. Nature (2013) 500(7463), 472-476.. 10.1038/nature12466

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today