GenJet™ In Vitro DNA Transfection Reagent for Keratinocytes

SKU:BHT2200020
Research Validated
Overview
Click light‑blue chips for details
GenJet™ In Vitro DNA Transfection Reagent for Keratinocytes is a SignaGen Laboratories reagent pre-optimized for plasmid DNA delivery into Keratinocytes, so the usual optimization step is not needed. Keratinocytes are difficult targets: nucleic acid uptake is limited, and the cells are sensitive to transfection-induced cytotoxicity. One milliliter of GenJet™ reagent is sufficient for approximately 600 transfections in 24-well plates or 300 transfections in 6-well plates.
Transfection Type DNA Transfection
Application Setting In Vitro
Optimized Cell Line Keratinocytes
Storage 4 °C
Shelf Life 24 months
Options selector
Catalog no. Size
SL100489-KERA-0P1ML 0.1 mL
SL100489-KERA-0P5ML 0.5 mL
SL100489-KERA-1P0ML 1.0 mL
SL100489-KERA-1P0MLX5 1.0 mL x 5
Available Options

Select the variant that best fits your experiment. Availability and lead time may vary by option.

  • Options: 4 variants available — select size from the variant selector.
  • Lead time: options listed in "Availability Content"; other statuses may take longer.
  • Storage: Store at 4°C. When maintained under recommended storage conditions, the reagent remains stable for at least 24 months.
  • Shipping: Please contact us to confirm shipping conditions for this product.
  • Upon receipt: refrigerate upon receipt.
  • Sales terms and conditions: Please review prior to ordering.
Field Specification
Storage 4 °C
Catalog no. (Mfr.) SL100489-KERA
Main SKU BHT2200020

Product Overview

Keratinocytes are difficult targets: nucleic acid uptake is limited, and the cells are sensitive to transfection-induced cytotoxicity. Proprietary formulation and optimization let GenJet™ reagent work around both obstacles, reaching high transfection efficiency with excellent cell viability kept intact, and as many as 50% GFP-positive cells under optimized conditions. GenJet™ DNA In Vitro Transfection Reagent for Keratinocytes is tuned in advance for primary and immortalized keratinocytes alike, whether human or mouse.

Specifications

Transfection Type DNA Transfection
Application Setting In Vitro
Pre-Optimized Yes — Pre-Optimized for Specific Cell Type
Optimized Cell Line Keratinocytes
Storage Store at 4°C. When maintained under recommended storage conditions, the reagent remains stable for at least 24 months.

Kit Contents

One milliliter of GenJet™ reagent is sufficient for approximately 600 transfections in 24-well plates or 300 transfections in 6-well plates.

Applications

This DNA transfection reagent supports a range of molecular biology applications including transient and stable transfection, reporter assays, protein expression studies, and gene function analysis in mammalian cell systems.

Safety & Handling

For Research Use Only (RUO) — Not for diagnostic or therapeutic use. Handle reagents according to institutional biosafety guidelines. Refer to the Safety Data Sheet (SDS) for detailed handling and disposal instructions.
Q.What cell types are compatible with GenJet™ In Vitro DNA Transfection Reagent for Keratinocytes?
A.This reagent is designed for broad compatibility with mammalian cell lines. It is pre-optimized for Keratinocytes for maximum efficiency. SignaGen offers pre-optimized versions for specific cell types.
Q.How should I store GenJet™ In Vitro DNA Transfection Reagent for Keratinocytes?
A.Store at 4°C. When maintained under recommended storage conditions, the reagent remains stable for at least 24 months. Follow the product datasheet for detailed storage and stability information.
Q.Do I need to optimize transfection conditions with this product?
A.No. GenJet™ In Vitro DNA Transfection Reagent for Keratinocytes is pre-optimized for Keratinocytes, so optimization is not required. Follow the provided protocol for best results.
Q.How many transfections does one vial provide?
A.One milliliter of GenJet™ reagent is sufficient for approximately 600 transfections in 24-well plates or 300 transfections in 6-well plates. Actual numbers depend on plate format and the amount of nucleic acid used.
Q.What are Keratinocytes?
A.Keratinocytes are difficult targets: nucleic acid uptake is limited, and the cells are sensitive to transfection-induced cytotoxicity.
Q.Is this product suitable for diagnostic or therapeutic use?
A.No. This product is for Research Use Only (RUO) and is not intended for diagnostic, therapeutic, or clinical applications.

Can't Find What You're Looking For? We can help you source the best match or customize a transfection solution for your study. Options may include pre-optimized formulations for a cell line not listed here, matching transfection buffer supplied with the reagent, DNA, siRNA or in vivo formats within the same reagent family, and bulk or custom packaging. Click Talk to a Scientist to submit a request form, email us at support@biohippo.com, or explore our Research Services for additional support. Our team will be in contact with you shortly.

Du J, Liao W, Wang H, et al.. MDIG-mediated H3K9me3 demethylation upregulates Myc by activating OTX2 and facilitates liver regeneration. Signal Transduct Target Ther (2023) 8(1), 351-351.. 10.1038/s41392-023-01575-5

Zhang X, McGinnis C, Yu G, et al.. Erythropoietin receptor on cDC1s dictates immune tolerance. Nature (2025). 10.1038/s41586-025-09824-z

Lee M, Siddoway B, Kaeser G, et al.. Somatic APP gene recombination in Alzheimer's disease and normal neurons. Nature (2018) 563(7733), 639-645.. 10.1038/s41586-018-0718-6

Konermann S, Brigham M, Trevino A, et al.. Optical control of mammalian endogenous transcription and epigenetic states. Nature (2013) 500(7463), 472-476.. 10.1038/nature12466

Get a Quote

Please use this form for bulk quantity requests or customized products.

Contact Information

Product Information

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today

Try Celltrypse Free – Request Your Sample Today

Experience the power of Celltrypse™, c-LEcta's innovative enzyme solution for gentle and efficient cell dissociation. Request your free sample and discover a superior alternative for your cell culture workflows.

Try Celltrypse Free – Request Your Sample Today