TE22 Mighty Small Transfer Tank
The Hoefer TE22 Mighty Small Transfer Tank moves proteins and nucleic acids from up to four mini gels (up to 9 x 10 cm) onto nylon, nitrocellulose or PVDF membranes in less than an hour. A built-in ceramic heat exchanger and cooling channel provide temperature control.
| Catalog No. | Model | Availability | Price | Qty | Order |
|---|---|---|---|---|---|
| TE22 | TE22 | In Stock | $1,411.10 |
|
Overview
What is TE22 Mighty Small Transfer Tank?
Product Overview
The Hoefer TE22 Mighty Small Transfer Tank transfers proteins and nucleic acids quickly and efficiently from small gels onto nylon, nitrocellulose or PVDF membranes. It holds up to four gels of up to 9 x 10 cm and completes a transfer in less than an hour. A built-in ceramic heat exchanger and an alumina-covered cooling channel provide temperature control.
Key Features
- Transfers up to four small gels, up to 9 x 10 cm, in less than an hour
- Uniform, strong electric field for efficient, even transfers
- Color-coded cassettes that are easy to assemble and load, ensuring correct orientation
- Tank design lets the cassettes apply equal pressure across the stack, preventing gel distortion
- Built-in ceramic heat exchanger for temperature control when used with an external cooling water bath
- Built-in alumina-covered cooling channel for temperature control, with no more than a 5°C temperature increase during a typical run
What's Included
- Lower Chamber with Heat Exchanger
- Safety Lid with High Voltage Leads
- Electrode Panels, 2 pcs
- Cassettes, 4 pcs
- Foam Sponges, 6 mm thick, 4 pcs
- Foam Sponges, 3 mm thick, 8 pcs
- Cassette Hook
- Blotter Paper, 9 x 10.5 cm, 25 sheets
Specifications
| Capacity | Up to four 9 x 10 cm gels |
|---|---|
| Maximum Power Settings | 100 V, 500 mA, 50 W |
| Maximum Temperature | 45°C |
| Indoor Use | 4 to 40°C |
| Humidity | Up to 80% |
| Unit Dimensions (W x H x D) | 14 x 24 x 16.5 cm |
| Basic Unit Weight | 2.00 kg |
Source: Hoefer published specifications.
Compatibility Notes
The TE22 is sized for mini gels up to 9 x 10 cm. For 15 x 21 cm gels, see the Hoefer TE42 or TE62 standard transfer tanks.
Details
Specifications
Applications
Applications & how to use
Western Blot (WB)
Detects a target protein in denatured, gel-separated lysates by antibody probing. Used to confirm protein identity, apparent molecular weight, and relative expression across samples.
Evidence
Validation & QC
Validation data for this product isn’t published yet.
Need specific QC or validation results — titer, purity, endotoxin, or assay data — for your application? Our scientific team can share what is available for this product and lot on request.
Request validation dataManufacturing
How it's made & quality control
Supplier quality control
Electrophoresis and blotting systems, and power supplies, are functionally tested for safety and performance before shipment.
Each instrument includes specifications, a test record and operating documentation; reagents include lot data.
Certificate of Conformance and warranty provided for instruments; technical support included.
Supplier-level quality statement. For lot-specific results, request the Certificate of Analysis for your batch.
Questions
Frequently asked questions
How many gels can the TE22 transfer at once?
Up to four small gels of up to 9 x 10 cm.
How long does a transfer take?
Hoefer states that up to four small gels can be transferred in less than an hour.
Which membranes can be used?
Nylon, nitrocellulose and PVDF membranes.
How is temperature controlled?
The tank has a built-in ceramic heat exchanger for use with an external cooling water bath, and an alumina-covered cooling channel with no more than a 5°C temperature increase during a typical run.
Answered by our team
Questions from researchers
No researcher questions have been answered for this product yet. Ask our technical team and we'll get back to you — approved answers are published here.
Ask our technical team
Reviewed by a scientist — typically answered within one business day.
Deals
Promotions
Codes apply at checkoutIn the literature
Research using this product
Every paper below mentions this product's catalogue number (or product name) in its full text — a text match, not a verified citation. Each entry shows what was measured, the sample type where the paper states it, and the sentence the catalogue number appears in, and a link to the figure showing that data — so you can confirm the use case before citing.
Auto-discovered from Europe PMC by manufacturer number / product name / keyword plus supplier. A match may reference a related product; confirm relevance before citing.
Customization
Sourcing & bulk orders
Operating guide. The Hoefer instruction manual for this unit is available in the Documents section of this page.
Explore
Collections featuring this product
This product is included in the curated collections below. Browse a collection to source everything for a workflow from a single cart.
Recently viewed