TE62 Standard Transfer Tank with Cooling Chamber
The Hoefer TE62 Standard Transfer Tank with Cooling Chamber transfers proteins and nucleic acids onto nylon, nitrocellulose or PVDF membranes. It takes up to four cooled cassettes per run, each holding one 15 x 21 cm gel or up to four 7 x 10 cm mini gels, and has a built-in ceramic heat exchanger.
| Catalog No. | Model | Availability | Price | Qty | Order |
|---|---|---|---|---|---|
| TE62 | TE62 | In Stock | $2,029.10 |
|
Overview
What is TE62 Standard Transfer Tank with Cooling Chamber?
Product Overview
The Hoefer TE62 Standard Transfer Tank with Cooling Chamber transfers proteins and nucleic acids quickly and evenly from polyacrylamide or agarose gels onto nylon, nitrocellulose or PVDF membranes, with good temperature control. It accepts up to four cassettes at once with cooling. Each cassette holds one 15 x 21 cm gel or up to four 7 x 10 cm mini gels.
Key Features
- Uniform, strong electric field for efficient, even transfers
- Color-coded cassettes that are easy to assemble, ensuring correct orientation
- Tank design lets the cassettes apply equal pressure across the stack
- Built-in ceramic heat exchanger for temperature control when used with an external cooling water bath
What's Included
- Lower Chamber with Heat Exchanger
- Safety Lid with High Voltage Leads
- Electrode Panels, 2 pcs
- Cassettes, 4 pcs
- Foam Sponges, 6 mm thick, 4 pcs
- Foam Sponges, 3 mm thick, 8 pcs
- Cassette Hook
- Blotter Paper, 14.5 x 21.5 cm, 25 sheets
Specifications
| Capacity | Up to four 15 x 21 cm gels; up to sixteen 7 x 10 cm gels |
|---|---|
| Maximum Power Settings | 100 V, 2 A, 200 W |
| Maximum Temperature | 45°C |
| Indoor Use | 4 to 40°C |
| Humidity | Up to 80% |
| Unit Dimensions (W x H x D) | 28 x 16.5 x 32 cm |
| Unit Weight | 5.40 kg |
Source: Hoefer published specifications.
Compatibility Notes
The built-in heat exchanger is used with an external cooling water bath. For transfers without a cooling chamber, see the Hoefer TE42; for small gels up to 9 x 10 cm, see the Hoefer TE22.
Details
Specifications
Applications
Applications & how to use
Western Blot (WB)
Detects a target protein in denatured, gel-separated lysates by antibody probing. Used to confirm protein identity, apparent molecular weight, and relative expression across samples.
Evidence
Validation & QC
Validation data for this product isn’t published yet.
Need specific QC or validation results — titer, purity, endotoxin, or assay data — for your application? Our scientific team can share what is available for this product and lot on request.
Request validation dataManufacturing
How it's made & quality control
Supplier quality control
Electrophoresis and blotting systems, and power supplies, are functionally tested for safety and performance before shipment.
Each instrument includes specifications, a test record and operating documentation; reagents include lot data.
Certificate of Conformance and warranty provided for instruments; technical support included.
Supplier-level quality statement. For lot-specific results, request the Certificate of Analysis for your batch.
Questions
Frequently asked questions
How many gels can the TE62 transfer?
Up to four cassettes run at once with cooling. Each cassette holds one 15 x 21 cm gel or up to four 7 x 10 cm mini gels, so up to sixteen mini gels per run.
What is needed for cooling?
The TE62 has a built-in ceramic heat exchanger that is used with an external cooling water bath.
How many cassettes are included?
Four cassettes are included, with 4 foam sponges of 6 mm, 8 foam sponges of 3 mm, a cassette hook and 25 sheets of 14.5 x 21.5 cm blotter paper.
What is the difference between the TE62 and the TE42?
The TE62 has a built-in heat exchanger, accepts up to four cassettes with cooling and ships with 4 cassettes. On the TE42 the TE47 heat exchanger is optional; it transfers up to two gels when cooled and ships with 2 cassettes.
Answered by our team
Questions from researchers
No researcher questions have been answered for this product yet. Ask our technical team and we'll get back to you — approved answers are published here.
Ask our technical team
Reviewed by a scientist — typically answered within one business day.
Deals
Promotions
Codes apply at checkoutIn the literature
Research using this product
Every paper below mentions this product's catalogue number (or product name) in its full text — a text match, not a verified citation. Each entry shows what was measured, the sample type where the paper states it, and the sentence the catalogue number appears in, and a link to the figure showing that data — so you can confirm the use case before citing.
Auto-discovered from Europe PMC by manufacturer number / product name / keyword plus supplier. A match may reference a related product; confirm relevance before citing.
Customization
Sourcing & bulk orders
Operating guide. The Hoefer instruction manual for this unit is available in the Documents section of this page.
Explore
Collections featuring this product
This product is included in the curated collections below. Browse a collection to source everything for a workflow from a single cart.
Recently viewed